Loading...
Search for:
96-well-plate
0.009 seconds
High-Throughput Sample Preparation on a 96-Well Plate and LC-MS Analysis of Thimerosal in Biological Products
, M.Sc. Thesis Sharif University of Technology ; Bagheri, Habib (Supervisor) ; Eshaghi, Ali (Supervisor)
Abstract
Thiomersal is an organomercury compound. This compound is a well established antiseptic and antifungal agent. It has been used as a preservative in vaccines, immuno-globulin preparations, skin test antigens, antivenins, ophthalmic and nasal products, and tattoo inks. Thiomersal is very toxic by inhalation, ingestion, and in contact with skin, with a danger of cumulative effects. It is also very toxic to aquatic organisms and may cause long-term adverse effects in aquatic environments.
Thiomersal's main use is as an antiseptic and antifungal agent in vaccines. In multidose injectable drug delivery systems, it prevents serious adverse effects such as the Staphylococcus infection that,...
Thiomersal's main use is as an antiseptic and antifungal agent in vaccines. In multidose injectable drug delivery systems, it prevents serious adverse effects such as the Staphylococcus infection that,...
High-Throughput Determination of Pesticide Residues by Solid-Phase Microextraction and Micro-Solid Phase Extraction on 96-Well Plate
, Ph.D. Dissertation Sharif University of Technology ; Bagheri, Habib (Supervisor) ; Es-haghi, Ali ($item.subfieldsMap.e)
Abstract
Novel high-throughput device and their applications as the microextraction systems for pesticide multiresidue determination is the centre of this research. 96 extracting unit based on solid phase microextraction and micro-Solid phase extraction were constructed and applied for high-throughput extraction.
In the first work, a high-throughput SPME on 96-well plate together with gas chromatography-mass spectrometry was developed for the determination of pesticide residues in cucumber samples. A home-made Teflon block consisting ninety-six holes was constructed to 96 SPME fibers being positioned in. SPME fibers consisted of stainless steel rods with a 1.0 cm polydimethylsiloxane tubing...
In the first work, a high-throughput SPME on 96-well plate together with gas chromatography-mass spectrometry was developed for the determination of pesticide residues in cucumber samples. A home-made Teflon block consisting ninety-six holes was constructed to 96 SPME fibers being positioned in. SPME fibers consisted of stainless steel rods with a 1.0 cm polydimethylsiloxane tubing...
Microwave-assisted extraction and high-throughput monolithic-polymer-based micro-solid-phase extraction of organophosphorus, triazole, and organochlorine residues in apple
, Article Journal of Separation Science ; Volume 39, Issue 3 , 2016 , Pages 576-583 ; 16159306 (ISSN) ; Es Haghi, A ; Basiri Pour, F ; Sharif University of Technology
Wiley-VCH Verlag
Abstract
A high-throughput micro-solid-phase extraction device based on a 96-well plate was constructed and applied to the determination of pesticide residues in various apple samples. Butyl methacrylate and ethylene glycol dimethacrylate were copolymerized as a monolithic polymer and placed in the cylindrically shaped stainless-steel meshes of 96-micro-solid-phase extraction device and used as an extracting unit. Before the micro-solid-phase extraction, microwave-assisted extraction was employed to facilitate the transfer of the pesticide residues from the apple matrix to liquid media. Then, 1 mL of the aquatic samples was transferred into the 96-well plate and the 96-micro-solid-phase extraction...
High-throughput micro-solid phase extraction on 96-well plate using dodecyl methacrylate-ethylen glycol dimethacrylate monolithic copolymer
, Article Analytica Chimica Acta ; Volume 792 , August , 2013 , Pages 59-65 ; 00032670 (ISSN) ; Es'haghi, A ; Es-haghi, A ; Mohammadkhani, E ; Sharif University of Technology
2013
Abstract
A novel high-throughput device based on 96-micro-solid phase extraction (96-μ-SPE) system was constructed for multiresidue determination of nine pesticides in aquatic samples. The extraction procedure was performed on a commercially available 96-well plate system. The extraction module consisted of 96 pieces of 1cm×3cm of cylindrically shaped stainless steel meshes. The prepared meshes were fixed in a home-made polytetrafluoroethylene-based constructed ninety-six holes block for possible simultaneous immersion of meshes into the center of individual wells. Dodecyl methacrylate and ethylene glycol dimethacrylate was copolymerized as a monolithic polymer and placed in the cylindrically shaped...
A high-throughput approach for the determination of pesticide residues in cucumber samples using solid-phase microextraction on 96-well plate
, Article Analytica Chimica Acta ; Volume 740 , 2012 , Pages 36-42 ; 00032670 (ISSN) ; Es'haghi, A ; Eshaghi, A ; Mesbahi, N ; Sharif University of Technology
Abstract
A high-throughput solid-phase microextraction (SPME) on 96-well plate together with gas chromatography-mass spectrometry (GC-MS) was developed for the determination of some selected pesticides in cucumber samples. Pieces with the length of 1.0cm of silicon tubing were precisely prepared and then coated on the end part of stainless steel wires. The prepared fibers were positioned in a home-made polytetrafluoroethylene (PTFE)-based constructed ninety-six holes block to have the possibility of simultaneous immersion of the SPME fibers into the center of individual wells. Pesticides such as diazinon, penconazol, tebuconazol, bitertanol, malathion, phosalone and chlorpyrifos-methyl were selected...