Loading...
Search for: acceleration-deceleration
0.006 seconds

    Efficient batch-mode mixing and flow patterns in a microfluidic centrifugal platform: a numerical and experimental study

    , Article Microsystem Technologies ; 2016 , Pages 1-13 ; 09467076 (ISSN) Mortazavi, S. M. A ; Tirandazi, P ; Normandie, M ; Saidi, M. S ; Sharif University of Technology
    Springer Verlag 
    Abstract
    During recent years centrifugal-based microfluidic devices known as Lab-on-a-CD have attracted a lot of attentions. Applications of these CD-based platforms are ubiquitous in numerous biological analyses and chemical syntheses. Mixing of different species in microscale is one of the essential operations in biochemical applications where this seemingly simple task remains a major obstruction. Application of centrifugal force, however, may significantly improve the flow agitation and mixing, especially when it is combined with the Coriolis force which acts perpendicular to centrifugal force. In this study, mixing process in minichambers located on a rotating platform under a periodic... 

    Efficient batch-mode mixing and flow patterns in a microfluidic centrifugal platform: a numerical and experimental study

    , Article Microsystem Technologies ; Volume 23, Issue 7 , 2017 , Pages 2767-2779 ; 09467076 (ISSN) Mortazavi, S. M. A ; Tirandazi, P ; Normandie, M ; Saidi, M. S ; Sharif University of Technology
    Abstract
    During recent years centrifugal-based microfluidic devices known as Lab-on-a-CD have attracted a lot of attentions. Applications of these CD-based platforms are ubiquitous in numerous biological analyses and chemical syntheses. Mixing of different species in microscale is one of the essential operations in biochemical applications where this seemingly simple task remains a major obstruction. Application of centrifugal force, however, may significantly improve the flow agitation and mixing, especially when it is combined with the Coriolis force which acts perpendicular to centrifugal force. In this study, mixing process in minichambers located on a rotating platform under a periodic... 

    Dynamic error analysis of gantry type coordinate measuring machines

    , Article Scientia Iranica ; Volume 14, Issue 3 , 2007 , Pages 278-290 ; 10263098 (ISSN) Ahmadian, M. T ; Vossoughi, G. R ; Ramezani, S ; Sharif University of Technology
    Sharif University of Technology  2007
    Abstract
    Coordinate Measuring Machines (CMMs) are designed for precision inspection of complex industrial products. The mechanical accuracy of CMMs depends on both static and dynamic sources of error. In automated CMMs, one of the dynamic error sources is vibration of the probe, due to inertia forces resulting from parts acceleration and deceleration. Modeling of a gantry type CMM, based on the Timoshenko beam theory with moving mass effects, is developed and the dynamic errors of the probe resulting from the acceleration and deceleration of moving parts, are calculated. Findings from analytical solution and dynamic modeling software indicate high accuracy and good agreement between the results. ©... 

    Surface wettability effect on the rising of a bubble attached to a vertical wall

    , Article International Journal of Multiphase Flow ; Volume 109 , 2018 , Pages 178-190 ; 03019322 (ISSN) Javadi, K ; Davoudian, S. H ; Sharif University of Technology
    Abstract
    This paper deals with the dynamics of rising bubbles attached to a vertical wall under different wettability conditions. Even though, bubbles rising freely in a liquid have extensively been studied, bubbles attached to a wall have not been fully understood. Therefore, in this work, rising bubbles attached to a vertical wall were numerically investigated by applying the ALE method along with adaptive mesh refinement schemes to properly resolve the bubble interface and its deformation. To consider wall wettability effects, different contact angles of 45° 90° and 105° were considered along with the case of freely rising bubbles. The problem was carried out at different Bond numbers of 0.27,... 

    Nonlinear dynamic analysis of a rectangular plate subjected to accelerated/decelerated moving load

    , Article Journal of Theoretical and Applied Mechanics ; Volume 53, Issue 1 , 2015 , Pages 151-166 ; 14292955 (ISSN) Mamandi, A ; Mohsenzadeh, R ; Kargarnovin, M. H ; Sharif University of Technology
    Polish Society of Theoretical and Allied Mechanics  2015
    Abstract
    In this paper, nonlinear dynamical behavior of a rectangular plate traveled by a moving mass as well as an equivalent concentrated force with non-constant velocity is studied. The nonlinear governing coupled partial differential equations (PDEs) of motion are derived by energy method using Hamilton's principle based on the large deflection theory in conjuncture with the von-Karman strain-displacement relations. Then Galerkin's method is used to transform the equations of motion into a set of three coupled nonlinear ordinary differential equations (ODEs) which then is solved in a semi-analytical way to get the dynamical response of the plate. Also, by using the Finite Element Method (FEM)... 

    Droplet dynamics in rotating flows

    , Article Advances in Colloid and Interface Science ; Volume 236 , 2016 , Pages 63-82 ; 00018686 (ISSN) Maneshian, B ; Javadi, K ; Taeibi Rahni, M ; Miller, R ; Sharif University of Technology
    Elsevier B.V  2016
    Abstract
    This paper deals with investigations of droplet dynamics in rotating flows. In many previous studies droplet dynamics was analyzed in simple unidirectional flows. To fill this gap, the focus of this study is an overview on investigations of droplet dynamics in a complex rotating flow. A Lattice Boltzmann Method with high potential in simulation of two-phase unsteady flows is applied to simulate the physics of the problem in a lid-driven cavity. In spite of its simple geometry, there is a complex rotating flow field containing different vortices and shear regions. The Reynolds number based on the cavity length scale and the upper wall velocity, ReL, is considered to be 1000. We discuss here...