Loading...
Search for: anti-scatter-grids
0.004 seconds

    Design of linear anti-scatter grid geometry with optimum performance for screen-film and digital mammography systems

    , Article Physics in Medicine and Biology ; Volume 60, Issue 15 , July , 2015 , Pages 5753-5765 ; 00319155 (ISSN) Khodajou Chokami, H ; Sohrabpour, M ; Sharif University of Technology
    Institute of Physics Publishing  2015
    Abstract
    A detailed 3D Monte Carlo simulation of the grid geometrical parameters in screen-film mammography (SFM) and digital mammography (DM) systems has been performed. A combination of IEC 60627:2013 international standard conditions and other more clinically relevant parameters were used for this simulation. Accuracy of our results has been benchmarked with previously published data and good agreement has been obtained. Calculations in a wide range of linear anti-scatter grid geometries have been carried out. The evaluated parameters for the SFM system were the Bucky factor (BF) and contrast improvement factor (CIF) and for the DM system it was signal differenceto- noise ratio improvement factor... 

    Mamsim: A computational software platform for measuring and optimizing imaging and dosimetry parameters in screen-film and digital mammography systems

    , Article 15th IEEE International Symposium on Medical Measurements and Applications, MeMeA 2020, 1 June 2020 through 3 June 2020 ; July , 2020 Khodajou Chokami, H ; Vahdat, B. V ; Ebrahimi Khankook, A ; Noorvand, M ; IEEE; IEEE Instrumentation and Measurement Society; IEEE Sensors Council Italy Chapter; Politecnica di Bari; Politecnico di Torino; Societa Italiana di Analisi del Movimento in Clinica ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2020
    Abstract
    The aim of this work is to develop a mammography Monte Carlo MCNP-FBSM based simulation platform called 'MamSim' that is able to model the detailed geometry and physics of commercial screen-film and digital mammography units. This simulation platform is designed to enable the virtual assessment and optimization of mammography protocols and parameters for obtaining the desired image quality while diminishing radiation dose to the patient in both contact and magnification modes. A graphical user interface generates MCNP-FBSM input files for simulating mammography units under various geometries and imaging protocols. We considered the full simulation of all components of mammography procedure...