Loading...
Search for: artery-occlusion
0.004 seconds

    Artificial neural network for predicting the safe temporary artery occlusion time in intracranial aneurysmal surgery

    , Article Journal of Clinical Medicine ; Volume 10, Issue 7 , 2021 ; 20770383 (ISSN) Shahjouei, S ; Ghodsi, S. M ; Zangeneh Soroush, M ; Ansari, S ; Kamali Ardakani, S ; Sharif University of Technology
    MDPI  2021
    Abstract
    Background. Temporary artery clipping facilitates safe cerebral aneurysm management, besides a risk for cerebral ischemia. We developed an artificial neural network (ANN) to predict the safe clipping time of temporary artery occlusion (TAO) during intracranial aneurysm surgery. Method. We devised a three-layer model to predict the safe clipping time for TAO. We considered age, the diameter of the right and left middle cerebral arteries (MCAs), the diameter of the right and left A1 segment of anterior cerebral arteries (ACAs), the diameter of the anterior communicating artery, mean velocity of flow at the right and left MCAs, and the mean velocity of flow at the right and left ACAs, as well... 

    Fluid-structure interaction simulation of blood flow and cerebral aneurysm: effect of partly blocked vessel

    , Article Journal of Vascular Research ; Volume 56, Issue 6 , 2019 , Pages 296-307 ; 10181172 (ISSN) Saeedi, M ; Shamloo, A ; Mohammadi, A ; Sharif University of Technology
    S. Karger AG  2019
    Abstract
    In this study, using fluid-structure interaction (FSI), 3-dimensional blood flow in an aneurysm in the circle of Willis-which is located in the middle cerebral artery (MCA)-has been simulated. The purpose of this study is to evaluate the effect of a partly blocked vessel on an aneurysm. To achieve this purpose, two cases have been investigated using the FSI method: in the first case, an ideal geometry of aneurysm in the MCA has been simulated; in the second case, modeling is performed for an ideal geometry of the aneurysm in the MCA with a partly blocked vessel. All boundary conditions, properties and modeling methods were considered the same for both cases. The only difference between the... 

    Finger photoplethysmogram pulse amplitude changes induced by flow-mediated dilation

    , Article Physiological Measurement ; Volume 29, Issue 5 , 2008 , Pages 625-637 ; 09673334 (ISSN) Zahedi, E ; Jaafar, R ; Mohd Ali, M. A ; Mohamed, A. L ; Maskon, O ; Sharif University of Technology
    2008
    Abstract
    This study was conducted to investigate the utility and efficacy of finger photoplethysmogram pulse amplitude (PPG-AC) in comparison with the standard Doppler ultrasound in assessing an endothelial function via flow-mediated dilation (FMD). High-resolution B-mode scanning of the right brachial artery (BA) of 31 healthy subjects aged 39.7 ± 11.3 (range 22-64) years and 52 risk subjects aged 47.7 ± 10.8 (range 30-65) years were performed before and after 4 min of upper arm occlusion. Concurrent with the ultrasound measurement (where color Doppler imaging was used to enhance arterial boundary detection), PPG signals were recorded from both index fingers for cross evaluation and comparison. Our...