    Monitoring temperature variation of reactance capacitance of water using a cylindrical cell probe

    , Article Journal of Applied Sciences ; Volume 9, Issue 4 , 2009 , Pages 752-758 ; 18125654 (ISSN) Behzadi, G ; Golnabi, H ; Sharif University of Technology
    2009
    Abstract
    In this study by using a capacitive cell probe the temperature variation of the electrical properties of the water liquids is investigated. Variation of the reactance capacitance parameter of liquids with temperature in the range of 17-60°C is measured for the plain water and water mixtures. The temperature variations of the capacitance for the cool distilled and tap water samples are studied for the range of 17-29°C obtained. Present results indicate an averaged variation of 4.69 μF/°C for the distilled water and 3.24 μF/°C for tap water in warm up process to a near room temperature. The cooling behaviors for the warm mineral, tap and salt water liquids are also investigated in this study....