Loading...
Search for: cardiotocography
0.005 seconds

    Fetal R-wave detection from multichannel abdominal ECG recordings in low SNR

    , Article Proceedings of the 31st Annual International Conference of the IEEE Engineering in Medicine and Biology Society: Engineering the Future of Biomedicine, EMBC 2009 ; 2009 , Pages 344-347 ; 1557170X (ISSN) Kharabian, S ; Shamsollahi, M. B ; Sameni, R ; Sharif University of Technology
    Abstract
    Abdominal recordings of fetal ECG (fECG) have lower signal-to-noise ratio (SNR) as compared with invasive procedures. In this paper we have combined two previously proposed methods, one for extracting fECG, called piCA and the other, a transformation based on Hilbert transform to enhance the R-peaks. The combination of these methods seems to work well in situations of noisy data and fetal repositioning. Also a comparison is done by using ICA in order to extract the fetal signals. Performance of both methods is studied separately. Results show that applying the transformation on the components extracted with the use of piCA (after maternal ECG cancellation), had a very good performance. Also,... 

    The application of empirical mode decomposition for the enhancement of cardiotocograph signals

    , Article Physiological Measurement ; Volume 30, Issue 8 , 2009 , Pages 729-743 ; 09673334 (ISSN) Krupa, B. N ; Mohd Ali, M. A ; Zahedi, E ; Sharif University of Technology
    2009
    Abstract
    Cardiotocograph (CTG) is widely used in everyday clinical practice for fetal surveillance, where it is used to record fetal heart rate (FHR) and uterine activity (UA). These two biosignals can be used for antepartum and intrapartum fetal monitoring and are, in fact, nonlinear and non-stationary. CTG recordings are often corrupted by artifacts such as missing beats in FHR, high-frequency noise in FHR and UA signals. In this paper, an empirical mode decomposition (EMD) method is applied on CTG signals. A recursive algorithm is first utilized to eliminate missing beats. High-frequency noise is reduced using EMD followed by the partial reconstruction (PAR) method, where the noise order is... 

    Multichannel electrocardiogram decomposition using periodic component analysis

    , Article IEEE Transactions on Biomedical Engineering ; Volume 55, Issue 8 , August , 2008 , Pages 1935-1940 ; 00189294 (ISSN) Sameni, R ; Jutten, C ; Shamsollahi, M. B ; Sharif University of Technology
    2008
    Abstract
    In this letter, we propose the application of the generalized eigenvalue decomposition for the decomposition of multichannel electrocardiogram (ECG) recordings. The proposed method uses a modified version of a previously presented measure of periodicity and a phase-wrapping of the RR-interval, for extracting the "most periodic" linear mixtures of a recorded dataset. It is shown that the method is an improved extension of conventional source separation techniques, specifically customized for ECG signals. The method is therefore of special interest for the decomposition and compression of multichannel ECG, and for the removal of maternal ECG artifacts from fetal ECG recordings. © 2006 IEEE  

    Antepartum fetal heart rate feature extraction and classification using empirical mode decomposition and support vector machine

    , Article BioMedical Engineering Online ; Volume 10 , 2011 ; 1475925X (ISSN) Krupa, N ; MA, M. A ; Zahedi, E ; Ahmed, S ; Hassan, F. M ; Sharif University of Technology
    Abstract
    Background: Cardiotocography (CTG) is the most widely used tool for fetal surveillance. The visual analysis of fetal heart rate (FHR) traces largely depends on the expertise and experience of the clinician involved. Several approaches have been proposed for the effective interpretation of FHR. In this paper, a new approach for FHR feature extraction based on empirical mode decomposition (EMD) is proposed, which was used along with support vector machine (SVM) for the classification of FHR recordings as 'normal' or 'at risk'.Methods: The FHR were recorded from 15 subjects at a sampling rate of 4 Hz and a dataset consisting of 90 randomly selected records of 20 minutes duration was formed from...