Loading...
Search for: cascaded-h-bridge-multilevel-converters
0.006 seconds

    A new fault tolerant scheme for cascaded H-Bridge multilevel converter

    , Article 2013 3rd International Conference on Electric Power and Energy Conversion Systems, EPECS 2013 ; 2013 ; 9781479906888 (ISBN) Ouni, S ; Noroozi, N ; Shahbazi, M ; Zolghadri, M ; Oraee, H ; Sharif University of Technology
    2013
    Abstract
    Multilevel converters are mainly used in high power applications (usually more than a few hundred kW). It is therefore important that they can continue working under faulty condition. In this paper, a new method is proposed to improve performance of CHB inverter under faulty condition. The proposed method will be compared with existing methods in term of voltage availability. The converter is simulated in Simulink and the results are provided. These results confirm the effectiveness of the proposed scheme, and are in accordance with the theoretical results  

    Fast short circuit power switch fault detection in cascaded H-bridge multilevel converter

    , Article IEEE Power and Energy Society General Meeting ; 2013 ; 19449925 (ISSN); 9781479913039 (ISBN) Shahbazi, M ; Zolghadri, M. R ; Poure, P ; Saadate, S ; Sharif University of Technology
    2013
    Abstract
    Multilevel converters are being widely used in a large number of power electronics applications. Due to the increased number of switching devices, they are more likely to have faults in their switches than the conventional converters. In order to have a balanced operation after a short circuit power switch fault occurrence, it is necessary to detect the fault location. In this paper, a fast power switch fault detection method is presented to identify the fault location. This method only needs one additional voltage sensor per phase, and is faster compared to most of the existing methods. Also it is easy for implementation on a FPGA chip. The proposed method is verified by computer... 

    Fast detection of open-switch fault in cascaded H-Bridge multilevel converter

    , Article 6th Annual International Power Electronics, Drive Systems, and Technologies Conference, PEDSTC 2015, 3 February 2015 through 4 February 2015 ; February , 2015 , Pages 538-543 ; 9781479976539 (ISBN) Shahbazi, M ; Zolghadri, M ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2015
    Abstract
    Cascaded H-Bridge converter has recently been utilized in different high-power applications due to its modular and simple structure. In order to have a balanced operation after a fault occurrence in this converter, it is necessary to detect the switch fault and its location. In this paper, a fast power switch fault detection method is presented to identify the fault and its location. Only one voltage measurement per phase is required by this method, and the fault detection is faster compared to the existing methods. Moreover, it is easy for implementation on an FPGA device, due to the use of simple math, relational and state machine blocks. The proposed method is verified by computer... 

    Fast detection of open-switch fault in cascaded H-bridge multilevel converter

    , Article Scientia Iranica ; Volume 25, Issue 3D , 2018 , Pages 1561-1570 ; 10263098 (ISSN) Shahbazi, M ; Zolghadri, M. R ; Khodabandeh, M ; Ouni, S ; Sharif University of Technology
    Sharif University of Technology  2018
    Abstract
    Cascaded H-bridge converter has been utilized recently in different high-power applications due to its modular and simple structure. In order to have a balanced operation after a fault occurrence in this converter, it is necessary to detect the switch fault and its location. In this paper, a fast power-switch fault detection method is presented to identify a fault and its location. Only one voltage measurement per phase is required by this method, and the fault detection is faster compared to the existing methods. Moreover, it is suitable for implementation on an FPGA device due to the use of simple math, relational, and state machine blocks. The proposed method is verified by computer...