Loading...
Search for: cell-isolation
0.004 seconds

    High-throughput, label-free isolation of white blood cells from whole blood using parallel spiral microchannels with u-shaped cross-section

    , Article Biosensors ; Volume 11, Issue 11 , 2021 ; 20796374 (ISSN) Mehran, A ; Rostami, P ; Saidi, M. S ; Firoozabadi, B ; Kashaninejad, N ; Sharif University of Technology
    MDPI  2021
    Abstract
    Rapid isolation of white blood cells (WBCs) from whole blood is an essential part of any WBC examination platform. However, most conventional cell separation techniques are labor-intensive and low throughput, require large volumes of samples, need extensive cell manipulation, and have low purity. To address these challenges, we report the design and fabrication of a passive, label-free microfluidic device with a unique U-shaped cross-section to separate WBCs from whole blood using hydrodynamic forces that exist in a microchannel with curvilinear geometry. It is shown that the spiral microchannel with a U-shaped cross-section concentrates larger blood cells (e.g., WBCs) in the inner... 

    Design and fabrication of a novel microfluidic system for enrichment of circulating tumor cells with the assistance of computer simulations

    , Article Avicenna Journal of Medical Biotechnology ; Volume 11, Issue 4 , 2019 , Pages 277-284 ; 20082835 (ISSN) Dorrigiv, D ; Vossoughi, M ; Alemzadeh, I ; Sharif University of Technology
    Avicenna Research Institute  2019
    Abstract
    Background: Cancer is the first cause of death in developed countries. The heterogeneous nature of cancer requires patient-specified treatment plans. One reliable approach is collecting Circulating Tumour Cells (CTCs) and using them for prognosis and drug response assessment purposes. CTCs are rare and their separation from normal cell requires high-accuracy methods. Methods: A microfluidic cell capture device to separate CTCs from peripheral blood is presented in this study. The CTC separation device applies hydrodynamic forces to categorize cells according to their sizes. The proposed device is designed and evaluated by numerical simulations and validated experimentally. The simulation... 

    Magnetoelectric nanocomposite scaffold for high yield differentiation of mesenchymal stem cells to neural-like cells

    , Article Journal of Cellular Physiology ; Volume 234, Issue 8 , 2019 , Pages 13617-13628 ; 00219541 (ISSN) Esmaeili, E ; Soleimani, M ; Ghiass, M. A ; Hatamie, S ; Vakilian, S ; Zomorrod, M. S ; Sadeghzadeh, N ; Vossoughi, M ; Hosseinzadeh, S ; Sharif University of Technology
    Wiley-Liss Inc  2019
    Abstract
    While the differentiation factors have been widely used to differentiate mesenchymal stem cells (MSCs) into various cell types, they can cause harm at the same time. Therefore, it is beneficial to propose methods to differentiate MSCs without factors. Herein, magnetoelectric (ME) nanofibers were synthesized as the scaffold for the growth of MSCs and their differentiation into neural cells without factors. This nanocomposite takes the advantage of the synergies of the magnetostrictive filler, CoFe 2 O 4 nanoparticles (CFO), and piezoelectric polymer, polyvinylidene difluoride (PVDF). Graphene oxide nanosheets were decorated with CFO nanoparticles for a proper dispersion in the polymer through... 

    A new insight to deformability correlation of circulating tumor cells with metastatic behavior by application of a new deformability-based microfluidic chip

    , Article Analytica Chimica Acta ; Volume 1186 , 2021 ; 00032670 (ISSN) Hakim, M ; Khorasheh, F ; Alemzadeh, I ; Vossoughi, M ; Sharif University of Technology
    Elsevier B.V  2021
    Abstract
    Isolation and characterization of circulating tumor cells (CTCs) found in blood samples of cancer patients have been considered as a reliable source for cancer prognosis and diagnosis. A new continuous microfluidic platform has been designed in this investigation for simultaneous capture and characterization of CTCs based on their deformability. The deformability-based chip (D-Chip) consists of two sections of separation and characterization where slanted weirs with a gap of 7 μm were considered. Although sometimes CTCs and leukocytes have the same size, the deformability differs in such a way that can be exploited for enrichment purposes. MCF7 and MDA-MB-231 cell lines were used for the... 

    Comparison of transplantation of bone marrow stromal cells (BMSC) and stem cell mobilization by granulocyte colony stimulating factor after traumatic brain injury in rat

    , Article Iranian Biomedical Journal ; Volume 14, Issue 4 , Oct , 2010 , Pages 142-149 ; 1028852X (ISSN) Bakhtiary, M ; Marzban, M ; Mehdizadeh, M ; Joghataei, M. T ; Khoei, S ; Pirhajati Mahabadi, V ; Laribi, B ; Tondar, M ; Moshkforoush, A ; Sharif University of Technology
    2010
    Abstract
    Background: Recent clinical studies of treating traumatic brain injury (TBI) with autologous adult stem cells led us to compare effect of intravenous injection of bone marrow mesenchymal stem cells (BMSC) and bone marrow hematopoietic stem cell mobilization, induced by granulocyte colony stimulating factor (G-CSF), in rats with a cortical compact device. Methods: Forty adult male Wistar rats were injured with controlled cortical impact device and divided randomly into four groups. The treatment groups were injected with 2 × 106 intravenous bone marrow stromal stem cell (n = 10) and also with subcutaneous G-CSF (n = 10) and sham-operation group (n = 10) received PBS and "bromodeoxyuridine... 

    The different fate of satellite cells on conductive composite electrospun nanofibers with graphene and graphene oxide nanosheets

    , Article Biomedical Materials (Bristol) ; Volume 11, Issue 2 , 2016 ; 17486041 (ISSN) Mahmoudifard, M ; Soleimani, M ; Hatamie, S ; Zamanlui, S ; Ranjbarvan, P ; Vossoughi, M ; Hosseinzadeh, S ; Sharif University of Technology
    Institute of Physics Publishing  2016
    Abstract
    Electrospinning of composite polymer solutions provides fantastic potential to prepare novel nanofibers for use in a variety of applications. The addition of graphene (G) and graphene oxide (GO) nanosheets to bioactive polymers was found to enhance their conductivity and biocompatibility. Composite conductive nanofibers of polyaniline (PANI) and polyacrylonitrile (PAN) with G and GO nanosheets were prepared by an electrospinning process. The fabricated membranes were investigated by physical and chemical examinations including scanning electron microscopy (SEM), Raman spectroscopy, x-ray diffraction (XRD) and tensile assay. The muscle satellite cells enriched by a pre-plating technique were...