Loading...
Search for: chromatographic-analysis
0.005 seconds
Total 21 records

    Partitioning of alkaline protease from Bacillus licheniformis (ATCC 21424) using PEG-K2HPO4 aqueous two-phase system

    , Article Fluid Phase Equilibria ; Volume 337 , January , 2013 , Pages 1-5 ; 03783812 (ISSN) Yavari, M ; Pazuki, G. R ; Vossoughi, M ; Mirkhani, S. A ; Seifkordi, A. A ; Sharif University of Technology
    2013
    Abstract
    An aqueous two-phase system (ATPS) containing polyethylene glycol (PEG) and potassium phosphate (K2HPO4) was used for partitioning and partial purification of alkaline protease produced by Bacillus licheniformis ATCC 21424. The effect of PEG molar mass, pH and concentration of NaCl salt addition on partition coefficient, yield and purification factor (PF) for ATPS were studied. The highest partition coefficient (5.3) was achieved in an ATPS of 25% (w/w) PEG 10,000 (g/mol) and 10% (w/w) NaCl at pH 9. Cation and anion exchange chromatography was employed for purification of alkaline protease from protein mixture and the yield and PF for enzyme fractions were obtained to make a comparison... 

    Composition of the volatile oils of Artemisia armenica lan. and Artemisia splendens willd. from Iran

    , Article Journal of Essential Oil Research ; Volume 22, Issue 2 , 2010 , Pages 126-128 ; 10412905 (ISSN) Kazemi, M ; Zand, M. R ; Roshanaei, K ; Mehrzad, M ; Rustaiyan, A
    2010
    Abstract
    The hydrodistilled oils of the aerial parts of Artemisia armeniaca and Artemisia splendens have been analyzed by a combination of GC and GC/MS. The main components of A. armeniaca were α-pinene (41.9%) and 1,8-cineole (20.6%) followed by spathulenol (6.7%) and limonene (5.6%). l,8-cineole(14.5%), germacrene D (14.3%), α-pinene (11.3%) and bicyclogermacrene (11.3%) were found to be the major constituents of A. splendens  

    N-way partial least squares with variable importance in projection combined to GC×GC-TOFMS as a reliable tool for toxicity identification of fresh and weathered crude oils

    , Article Analytical and Bioanalytical Chemistry ; Volume 407, Issue 1 , January , 2015 , Pages 285-295 ; 16182642 (ISSN) Mostafapour, S ; Parastar, H ; Sharif University of Technology
    Springer Verlag  2015
    Abstract
    In this study, N-way partial least squares (NPLS) is proposed to correlate comprehensive two-dimensional gas chromatography-time of flight mass spectrometry (GC×GCTOFMS) data of different aromatic oil fractions (fresh and weathered) to their toxicity values. Before NPLS modeling, since drift and wander of baseline interfere with information of sought analytes in GC×GC-TOFMS data, a novel method called two-dimensional asymmetric least squares is thus developed for comprehensive correction of the baseline contributions in both chromatographic dimensions. The algorithmis termed comprehensive because it functions to correct the entire chromatogram in both dimensions and it preserves the... 

    Purification and zymography of lipase from aspergillus Niger PTCC5010

    , Article International Journal of Engineering, Transactions B: Applications ; Volume 28, Issue 8 , 2015 , Pages 1115-1123 ; 1728-144X (ISSN) Ghamari, M ; Alemzadeh, I ; Tabatabaee Yazdi, F ; Vossoughi, M ; Varidi, M ; Sharif University of Technology
    Materials and Energy Research Center  2015
    Abstract
    In this study, Lipase from Aspergillus Niger after extraction of medium culture was precipitated with different percentages of acetone and purified by ion exchange chromatography using SP-Sepharose HP and Q-Sepharose HP. The process of purification of the enzyme was studied by electrophoresis and the molecular weight was detected and determined by Zymography using overlying containing phenol red and Rhodamine B. The results showed that the vast majority of lipase from this strain has been precipitated by 70% saturation acetone, and leads to the 1.67 fold the purified enzyme, with special activities 32.8 U. mg-1 and efficiency of 38.5%. Using two-phase chromatography, enzyme specific activity... 

    Novel aspects of application of cadmium telluride quantum dots nanostructures in radiation oncology

    , Article Applied Physics A: Materials Science and Processing ; Volume 123, Issue 8 , 2017 ; 09478396 (ISSN) Fazaeli, Y ; Zare, H ; Karimi, S ; Rahighi, R ; Feizi, S ; Sharif University of Technology
    Springer Verlag  2017
    Abstract
    In the last two decades, quantum dots nanomaterials have garnered a great deal of scientific interest because of their unique properties. Quantum dots (QDs) are inorganic fluorescent nanocrystals in the size range between 1 and 20 nm. Due to their structural properties, they possess distinctive properties and behave in different way from crystals in macro scale, in many branches of human life. Cadmium telluride quantum dots (CdTe QDs) were labeled with 68Ga radio nuclide for fast in vivo targeting and coincidence imaging of tumors. Using instant paper chromatography, the physicochemical properties of the Cadmium telluride quantum dots labeled with 68Ga NPs (68Ga@ CdTe QDs) were found high... 

    Optimization of HFDS production from date syrup

    , Article International Journal of Engineering, Transactions B: Applications ; Volume 21, Issue 2 , 2008 , Pages 127-134 ; 1728-144X (ISSN) Jamshidi Mokhber, M ; Alemzadeh, I ; Vossoughi, M ; Sharif University of Technology
    Materials and Energy Research Center  2008
    Abstract
    Fructose is utilized as a common sweetener in many food industries. Today, a large amount of HFCS (high fructose corn syrup, an equilibrium mixture of glucose and fructose) is produced by glucose isomerase, immobilized enzymes from corn starch. There are a lot of date palms in Iran. Date is a favorable source of carbohydrates, and a suitable source for HFDS (high fructose date syrup) production. In this investigation, date syrup properties were first determined and the operational conditions for glucose isomerase application were optimized respectively. Ion exchange chromatography has been utilized for carbohydrate separation. Fructose obtained from chromatographic column reached 90 %... 

    Characterization of essential oil components of Iranian geranium oil using gas chromatography-mass spectrometry combined with chemometric resolution techniques

    , Article Journal of Chromatography A ; Volume 1114, Issue 1 , 2006 , Pages 154-163 ; 00219673 (ISSN) Jalali Heravi, M ; Zekavat, B ; Sereshti, H ; Sharif University of Technology
    2006
    Abstract
    The essential oil components of geranium oil cultivated in center of Iran were identified and determined using gas chromatography-mass spectrometry data combined with the chemometric resolution techniques. A total of 61 components accounting for 91.51% were identified using similarity searches between the mass spectra and MS database. This number was extended to 85 components using chemometric techniques. Various chemometric methods such as morphological scores, simplified Borgen method (SBM) and fixed size moving window evolving factor analysis (FSMWEFA) were used for determining the number of components, pure variables, zero concentration and selective regions. Then the overlapping peak... 

    Central composite design with the help of multivariate curve resolution in loadability optimization of RP-HPLC to scale-up a binary mixture

    , Article Journal of Separation Science ; Volume 39, Issue 6 , 2016 , Pages 1031-1040 ; 16159306 (ISSN) Taheri, M ; Moazeni Pourasil, R. S ; Sheikh Olia Lavasani, M ; Karami, A ; Ghassempour, A ; Sharif University of Technology
    Wiley-VCH Verlag 
    Abstract
    Chromatographic method development for preparative targets is a time-consuming and subjective process. This can be particularly problematic because of the use of valuable samples for isolation and the large consumption of solvents in preparative scale. These processes could be improved by using statistical computations to save time, solvent and experimental efforts. Thus, contributed by ESI-MS, after applying DryLab software to gain an overview of the most effective parameters in separation of synthesized celecoxib and its co-eluted compounds, design of experiment software that relies on multivariate modeling as a chemometric approach was used to predict the optimized touching-band... 

    Turnip (brassica rapa) peroxidase: Purification and characterization

    , Article Industrial and Engineering Chemistry Research ; Volume 48, Issue 23 , Volume 48, Issue 23 , 2009 , Pages 10614-10618 ; 08885885 (ISSN) Motamed, S ; Ghaemmaghami, F ; Alemzadeh, I ; Sharif University of Technology
    ACS  2009
    Abstract
    Partial purification of plant peroxidase from turnip (Brassica rapa) was optimized. Aqueous two phase system and precipitation by ammonium sulfate (as two parallel purification methods) were used. Polyethylene glycol/ammonium sulfate/NaCl (25:7:3%, w/v) system followed by gel-filtration chromatography gave a purification factor of about 36 fold. On the other hand, ammonium sulfate precipitation (60-80% deg) followed by gel filtration gave only about 13 purification fold. Hence, the aqueous two-phase system was more efficient and useful method as a primary purification step since it was less laborious, less time-consuming, and led to more purification factor. The partially purified turnip... 

    Multivariate optimization of hydrodistillation-headspace solvent microextraction of thymol and carvacrol from Thymus transcaspicus

    , Article Talanta ; Volume 79, Issue 3 , 2009 , Pages 695-699 ; 00399140 (ISSN) Kiyanpour, V ; Fakhari, A. R ; Alizadeh, R ; Asghari, B ; Jalali Heravi, M ; Sharif University of Technology
    2009
    Abstract
    In this paper multivariate response surface methodology (RSM) has been used for the optimization of hydrodistillation-headspace solvent microextraction (HD-HSME) of thymol and carvacrol in Thymus transcaspicus. Quantitative determination of compounds of interest was performed simultaneously using gas chromatography coupled with flame ionization detector (GC-FID). Parameters affecting the extraction efficiency were assessed and the optimized values were 5 min, 2 μL and 3 min for the extraction time, micro-drop volume and cooling time after extraction, respectively. The amounts of analyte extracted increased with plant weight. The calibration curves were linear in the ranges of 6.25-81.25 and... 

    Enhancing biosurfactant production from an indigenous strain of Bacillus mycoides by optimizing the growth conditions using a response surface methodology

    , Article Chemical Engineering Journal ; Volume 163, Issue 3 , October , 2010 , Pages 188-194 ; 13858947 (ISSN) Najafi, A. R ; Rahimpour, M. R ; Jahanmiri, A. H ; Roostaazad, R ; Arabian, D ; Ghobadi, Z ; Sharif University of Technology
    2010
    Abstract
    In this study, we have investigated the potential of a native bacterial strain isolated from an Iranian oil field for the production of biosurfactant. The bacterium was identified to be Bacillus mycoides by biochemical tests and 16S ribotyping. The biosurfactant, which was produced by this bacterium, was able to reduce the surface tension of media to 34. mN/m. Compositional analysis of the produced biosurfactant has been carried out by thin layer chromatography (TLC) and FT-IR. The biosurfactant produced by the isolate was characterized as lipopeptide derivative. Biosurfactant production was optimized by the combination of central composite design (CCD) and response surface methodology... 

    The impact of CO2 injection and pressure changes on asphaltene molecular weight distribution in a heavy crude oil: An experimental study

    , Article Petroleum Science and Technology ; Volume 28, Issue 17 , 2010 , Pages 1728-1739 ; 10916466 (ISSN) Sadeqimoqadam, M ; Firoozinia, H ; Kharrat, R ; Ghazanfari, M. H ; Sharif University of Technology
    Abstract
    This work concerns observing the pressure as well as CO2 mole percentage effects on asphaltene molecular weight distributions at reservoir conditions. A high-pressure, high-temperature asphaltene measurement setup was applied, and the amount of precipitated asphaltene at different pressures as well as CO2 mole percentage in an Iranian heavy crude oil was measured. Moreover, the asphaltene molecular weight distributions during titration of crude oil with different n-alkanes were investigated. The gel permeation chromatography (GPC) apparatus was used for characterization of asphaltene molecular weight under different conditions. It has been observed that some thermodynamic changes such as... 

    Self-modeling curve resolution techniques applied to comparative analysis of volatile components of Iranian saffron from different regions

    , Article Analytica Chimica Acta ; Volume 662, Issue 2 , 2010 , Pages 143-154 ; 00032670 (ISSN) Jalali Heravi, M ; Parastar, H ; Ebrahimi Najafabadi, H ; Sharif University of Technology
    Abstract
    Volatile components of saffron from different regions of Iran were extracted by ultrasonic-assisted solvent extraction (USE) and were analyzed by gas chromatography-mass spectrometry (GC-MS). Self-modeling curve resolution (SMCR) was proposed for resolving the co-eluted GC-MS peak clusters into pure chromatograms and mass spectra. Multivariate curve resolution-objective function minimization (MCR-FMIN) and multivariate curve resolution-alternating least square (MCR-ALS) were successfully used for this purpose. The accuracy of the qualitative and quantitative results was improved considerably using SMCR techniques. Comparison of the results of saffron from different regions of Iran showed... 

    Interactive optimization of biosurfactant production by Paenibacillus alvei ARN63 isolated from an Iranian oil well

    , Article Colloids and Surfaces B: Biointerfaces ; Volume 82, Issue 1 , 2011 , Pages 33-39 ; 09277765 (ISSN) Najafi, A. R ; Rahimpour, M. R ; Jahanmiri, A. H ; Roostaazad, R ; Arabian, D ; Soleimani, M ; Jamshidnejad, Z ; Sharif University of Technology
    Abstract
    The potential of an indigenous bacterial strain isolated from an Iranian oil field for the production of biosurfactant was investigated in this study. After isolation, the bacterium was characterized to be Paenibacillus alvei by biochemical tests and 16S ribotyping. The biosurfactant, which was produced by this bacterium, was able to lower the surface tension of media to 35. mN/m. Accordingly, thin layer chromatography (TLC) and FT-IR has been carried out to determine compositional analysis of the produced biosurfactant. After all the tests related to characterization of the biosurfactant produced by the isolated bacterium, it was characterized as lipopeptide derivative. The combination of... 

    Characterization of volatile components of Iranian saffron using factorial-based response surface modeling of ultrasonic extraction combined with gas chromatography-mass spectrometry analysis

    , Article Journal of Chromatography A ; Volume 1216, Issue 33 , 2009 , Pages 6088-6097 ; 00219673 (ISSN) Jalali Heravi, M ; Parastar, H ; Ebrahimi Najafabadi, H ; Sharif University of Technology
    2009
    Abstract
    The volatile components of Iranian saffron were extracted using ultrasonic solvent extraction (USE) technique and then were separated and detected by gas chromatography-mass spectrometry (GC-MS). Variables affecting the extraction procedure were screened by using a 25-1 fractional factorial design and among them; sample amount, solvent volume, solvent ratio and extraction time were optimized by applying a rotatable central composite design (CCD). The optimum values of factors were: 2.38 g sample, 29.04 mL solvent, 69.23% MeOH solvent ratio and 71.8 min for the extraction time. Forty constituents were identified for Iranian saffron by GC-MS representing 90% of the total peak area. The major... 

    Development of a method for analysis of Iranian damask rose oil: combination of gas chromatography-mass spectrometry with Chemometric techniques

    , Article Analytica Chimica Acta ; Volume 623, Issue 1 , 8 August , 2008 , Pages 11-21 ; 00032670 (ISSN) Jalali Heravi, M ; Parastar, H ; Sereshti, H ; Sharif University of Technology
    2008
    Abstract
    Gas chromatography-mass spectrometry (GC-MS) combined with Chemometric resolution techniques were proposed as a method for the analysis of volatile components of Iranian damask rose oil. The essential oil of damask rose was extracted using hydrodistillation method and analyzed with GC-MS in optimized conditions. A total of 70 components were identified using similarity searches between mass spectra and MS database. This number was extended to 95 components with concentrations higher than 0.01% accounting for 94.75% of the total relative content using Chemometric techniques. For the first time in this work, an approach based upon subspace comparison is used for determination of the chemical... 

    Liquid-liquid-liquid microextraction followed by HPLC with UV detection for quantitation of ephedrine in urine

    , Article Journal of Separation Science ; Volume 31, Issue 18 , 2008 , Pages 3212-3217 ; 16159306 (ISSN) Bagheri, H ; Khalilian, F ; Ahangar, L. E ; Sharif University of Technology
    2008
    Abstract
    Liquid-liquid-liquid microextraction (LLLME) in combination with HPLC and UV detection has been used as a sensitive method for the determination of ephedrine in urine samples. Extraction process was performed in a homemade total glass vial without using a Teflon ring, usually employed. Ephedrine was first extracted from 3.5 mL of urine sample (pH 12) into a microfilm of toluene/benzene (50:50). The analyte was subsequently back extracted into an acidic microdrop solution (pH 2) suspended in the organic phase. The extract was then injected into the HPLC system directly. An enrichment factor of 137 along with a good sample clean-up was obtained under the optimized conditions. The calibration... 

    Towards obtaining more information from gas chromatography-mass spectrometric data of essential oils: An overview of mean field independent component analysis

    , Article Journal of Chromatography A ; Volume 1217, Issue 29 , 2010 , Pages 4850-4861 ; 00219673 (ISSN) Jalali Heravi, M ; Parastar, H ; Sereshti, H ; Sharif University of Technology
    2010
    Abstract
    Mean field independent component analysis (MF-ICA) along with other chemometric techniques was proposed for obtaining more information from multi-component gas chromatographic-mass spectrometric (GC-MS) signals of essential oils (mandarin and lemon as examples). Using these techniques, some fundamental problems during the GC-MS analysis of essential oils such as varying baseline, presence of different types of noise and co-elution have been solved. The parameters affecting MF-ICA algorithm were screened using a 25 factorial design. The optimum conditions for MF-ICA algorithm were followed by deconvolution of complex GC-MS peak clusters. The number of independent components (ICs) (chemical... 

    Immersed sol-gel based amino-functionalized SPME fiber and HPLC combined with post-column photochemically induced fluorimetry derivatization and fluorescence detection of pyrethroid insecticides from water samples

    , Article Journal of Separation Science ; Volume 32, Issue 17 , 2009 , Pages 2912-2918 ; 16159306 (ISSN) Bagheri, H ; Ghanbarnejad, H ; Khalilian, F ; Sharif University of Technology
    2009
    Abstract
    A method based on direct immersion solid-phase microextraction (DI-SPME) coupled with high performance liquid chromatography combined with post-column photochemically induced fluorimetry derivatization and fluorescence detection (HPLC-PIF-FD) was developed to extract three pyrethroid insecticides, i.e. cyfluthrin, cypermethrin, and flumethrin from water samples. A sol-gel based coating fiber using 3-(trimethoxysilyl propyl) amine as precursor was prepared and used for the extraction of the pyrethroids from groundwater samples. A post-column photochemical reactor was designed and constructed for the derivatization of these environmentally important pollutants to increase their fluorescence... 

    An interior needle electropolymerized pyrrole-based coating for headspace solid-phase dynamic extraction

    , Article Analytica Chimica Acta ; Volume 634, Issue 2 , 2009 , Pages 209-214 ; 00032670 (ISSN) Bagheri, H ; Babanezhad, E ; Khalilian, F ; Sharif University of Technology
    2009
    Abstract
    A headspace solid-phase dynamic extraction (HS-SPDE) technique was developed by the use of polypyrrole (PPy) sorbent, electropolymerized inside the surface of a needle, as a possible alternative to solid-phase microextraction (SPME). Thermal desorption was subsequently, employed to transfer the extracted analytes into the injection port of a gas chromatography-mass spectrometry (GC-MS). The PPy sorbent including polypyrrole-dodecyl sulfate (PPy-DS) was deposited on the interior surface of a stainless steel needle from the corresponding aqueous electrolyte by applying a constant deposition potential. The homogeneity and the porous surface structure of the coating were examined using the...