Loading...
Search for: coating-deposition
0.011 seconds

    Biodegradation behavior of polymethyl methacrylate−bioactive glass 45S5 composite coated magnesium in simulated body fluid

    , Article Transactions of Nonferrous Metals Society of China (English Edition) ; Volume 32, Issue 7 , 2022 , Pages 2216-2228 ; 10036326 (ISSN) ROUEIN, Z ; Jafari, H ; Pishbin, F ; Mohammadi, R ; Simchi, A ; Sharif University of Technology
    Nonferrous Metals Society of China  2022
    Abstract
    The biodegradation behavior of Mg, coated by polymethyl methacrylate as well as polymethyl methacrylate (PMMA)−bioactive glass (BG) composite was investigated. Electrophoretic deposition and dip coating techniques were adopted to prepare composite coating using a suspension of different percentages of the above two chemical materials. The deposited coatings were characterized using SEM, EDS, FTIR, and water contact angle measurements. Biodegradation behavior study of the coated Mg was performed using linear polarization, impedance spectroscopy, and immersion tests in simulated body fluid. The compact and homogeneous composite coating was developed as evidenced by electron microscopy results.... 

    Tribological properties of Ni–P–SiO2 nanocomposite coating on aluminum

    , Article Colloid Journal ; Volume 77, Issue 5 , September , 2015 , Pages 628-634 ; 1061933X (ISSN) Sadreddini, S ; Afshar, A ; Jazani, M. A ; Sharif University of Technology
    Maik Nauka Publishing / Springer SBM  2015
    Abstract
    In this study, the effects of different concentrations of SiO2 nanosized particles in the bath on deposition rate, surface morphology and wear behavior of Ni–P–SiO2 composite coatings were investigated. The rate of coating deposition was influenced by the incorporation of SiO2 particles. The observations of microstructural morphology were performed with field emission scanning electron microscopy. The amount of deposited SiO2 was examined by X-ray energy dispersive analysis. The results showed that for the coating produced at 12.5 g/L of nanoparticles, the amount of co-deposited SiO2 nanoparticles and microhardness reached their maximal... 

    Zn-Ni Electrophosphating on galvanized steel using cathodic and anodic electrochemical methods

    , Article Surface and Coatings Technology ; January , 2015 ; 02578972 (ISSN) Darband, G. B ; Afshar, A ; Aliabadi, A ; Sharif University of Technology
    Elsevier  2015
    Abstract
    Electrophosphating is the novel method for accelerating the low temperature phosphating bath. This method can be performed as cathodic and anodic treatments. Both of them influence the coating deposition mechanism and therefore coating properties. In this study Zn-Ni electrophosphate coating was applied on galvanized steel using cathodic and anodic electrochemical methods. Microstructure, composition and corrosion resistance of coating were characterized by using a scanning electron microscopy, X-ray diffraction method and potentiodynamic polarization test respectively. The results of this study indicated that, by using cathodic method, compact phosphate coating with high corrosion... 

    Zn–Ni electrophosphating on galvanized steel using cathodic and anodic electrochemical methods

    , Article Surface and Coatings Technology ; Volume 306 , 2016 , Pages 497-505 ; 02578972 (ISSN) Barati Darband, Gh ; Afshar, A ; Aliabadi, A ; Sharif University of Technology
    Elsevier B.V  2016
    Abstract
    Electrophosphating is the novel method for accelerating the low temperature phosphating bath. This method can be performed as cathodic and anodic treatments. Both of them influence the coating deposition mechanism and therefore coating properties. In this study Zn–Ni electrophosphate coating was applied on galvanized steel using cathodic and anodic electrochemical methods. Microstructure, composition and corrosion resistance of coating were characterized by using a scanning electron microscopy, X-ray diffraction method and potentiodynamic polarization test respectively. The results of this study indicated that, by using cathodic method, compact phosphate coating with high corrosion... 

    Surface modifications of titanium implants by multilayer bioactive coatings with drug delivery potential: antimicrobial, biological, and drug release studies

    , Article JOM ; Volume 68, Issue 4 , 2016 , Pages 1100-1108 ; 10474838 (ISSN) Ordikhani, F ; Petrova Zustiak, S ; Simchi, A ; Sharif University of Technology
    Abstract
    Recent strategies to locally deliver antimicrobial agents to combat implant-associated infections—one of the most common complications in orthopedic surgery—are gaining interest. However, achieving a controlled release profile over a desired time frame remains a challenge. In this study, we present an innovative multifactorial approach to combat infections which comprises a multilayer chitosan/bioactive glass/vancomycin nanocomposite coating with an osteoblastic potential and a drug delivery capacity. The bioactive drug-eluting coating was prepared on the surface of titanium foils by a multistep electrophoretic deposition technique. The adopted deposition strategy allowed for a high... 

    Mechanism of Al-Si codeposition on In738LC through single-step diffusion process

    , Article International Journal of Surface Science and Engineering ; Volume 11, Issue 1 , 2017 , Pages 1-11 ; 1749785X (ISSN) Nikzad, S ; Abdi, M ; Rastegari, S ; Sharif University of Technology
    Abstract
    The out-of-pack cementation method was applied to coat the Nickel-based super alloy IN738LC with Si-modified aluminide. Different mixtures of the pack containing pure Al, Si, alumina powders as an inert filler, and NH4Cl as a halide salt activator were used for co-deposition at 950 and 1,050°C. The results showed although the amount of subhalide vapour pressures of Al and Si were equal at 1,050°C, Al atoms diffused only after Si atoms had been deposited. Before heat treatment, the coating thickness formed by the pack containing 2.3 wt.% Al was 6 μm more than that containing 3.5 wt.% Al. After heat treatment, thickening coatings formed within the pack containing 2.3 wt.% Al was less than that... 

    Physicochemical and biological properties of electrodeposited graphene oxide/chitosan films with drug-eluting capacity

    , Article Carbon ; Volume 84, Issue C , April , 2015 , Pages 91-102 ; 00086223 (ISSN) Ordikhani, F ; Ramezani Farani, M ; Dehghani, M ; Tamjid, E ; Simchi, A ; Sharif University of Technology
    Elsevier Ltd  2015
    Abstract
    In this study, novel graphene oxide/chitosan nanocomposite coatings with long term drugeluting potential are presented. The coatings are fabricated by the facile and reproducible electrophoretic deposition technique. Analysis of the prepared films shows that the graphene oxide nanosheets are exfoliated in the chitosan matrix. Fourier-transform infrared spectrometry reveals polymer attachment to the carboxylic bonds of graphene oxide, providing a strong interaction and exfoliation of the nanolayers. In vitro viability assay by human osteosarcoma cells (MG-63) demonstrates that the nanocomposite films are highly biocompatible up to 30 wt% graphene oxide, but at higher concentrations a slight... 

    Investigation and optimization of SDS and key parameters effect on the nickel electroless coatings properties by Taguchi method

    , Article Journal of Coatings Technology Research ; Volume 7, Issue 5 , 2010 , Pages 547-555 ; 15470091 (ISSN) Farzaneh, A ; Ehteshamzadeh, M ; Ghorbani, M ; Vazifeh Mehrabani, J ; Sharif University of Technology
    2010
    Abstract
    In this research, the influence of anionic surfactant sodium dodecyl sulfate (SDS), pH, substrate finishing, and annealing temperature on the surface morphology and hardness of the electroless nickel phosphorus (ENi-P) coatings were studied. Taguchi's experimental design method was used. Parameters selected in three levels and L9 from orthogonal robust array design were employed. Surface roughnesses of the deposits were measured using a stylus instrument. Scanning electron microscope and x-ray diffraction analysis were implemented to study surface morphologies and phase composition, respectively. Microhardness of the ENi-P deposits was measured using a microhardness tester at three trials... 

    Deposition of metallic molybdenum thin films on 304L steel substrate by SUT-PF

    , Article Surface and Coatings Technology ; 2016 ; 02578972 (ISSN) Hosseinzadeh, A ; Nazmabadi, M ; Vosoughi, N ; Sharif University of Technology
    Elsevier B. V 
    Abstract
    The present research work aims to employ plasma focus in order to deposit molybdenum (Mo) on the 304 stainless steel substrate. The processing parameters were shot numbers as well as the distance of substrate from the anode tip. Stereo, atom force microscopy (AFM) and field emission-scanning electron microscopy (FE-SEM) equipped with energy dispersive X-ray spectroscopy (EDS) were used to study the deposited coatings. Microhardness measurements were also performed on the coatings. Results indicated that the plasma focus can be successfully applied to deposit Mo anode on the stainless steel substrate. The coatings contained discrete pores with sizes varying by processing parameters. The... 

    Fabrication of selenization-free superstrate-type CuInS2 solar cells based on all-spin-coated layers

    , Article Materials Chemistry and Physics ; Volume 186 , 2017 , Pages 446-455 ; 02540584 (ISSN) Cheshme khavar, A. H ; Mahjoub, A ; Samghabadi, F. S ; Taghavinia, N ; Sharif University of Technology
    Elsevier Ltd  2017
    Abstract
    Today manufacturing of high efficiency chalcogenide thin film solar cells is based on high cost vacuum-based deposition processes at high temperature (>500 °C) and in chalcogen -containing atmosphere. In this paper, we introduce a simple vacuum-free and selenization-free, solution processing for fabricating a superstrate-type CuInS2 (CIS) solar cell. The absorber, buffer and blocking layers were all deposited by spin coating of molecular precursor inks. We demonstrate the deposition of In2S3 buffer layer by sol-gel spin casting for the first time. The rapid sintering process of CIS layer was carried out at 250 °C that is considered a very low temperature in CIGS thin-film technologies. A... 

    The effect of titanium dioxide (TiO2) nanoparticles on hydroxyapatite (HA)/TiO2 composite coating fabricated by electrophoretic deposition (EPD)

    , Article Journal of Materials Engineering and Performance ; Volume 27, Issue 5 , May , 2018 , Pages 2338-2344 ; 10599495 (ISSN) Amirnejad, M ; Afshar, A ; Salehi, S ; Sharif University of Technology
    Springer New York LLC  2018
    Abstract
    Composite coatings of Hydroxyapatite (HA) with ceramics, polymers and metals are used to modify the surface structure of implants. In this research, HA/TiO2 composite coating was fabricated by electrophoretic deposition (EPD) on 316 stainless steel substrate. HA/TiO2 composite coatings with 5, 10 and 20 wt.% of TiO2, deposited at 40 V and 90 s as an optimum condition. The samples coated at this condition led to an adherent, continuous and crack-free coating. The influence of TiO2 content was studied by performing different characterization methods such as scanning electron microscopy (SEM), energy dispersive x-ray spectroscopy (EDS), corrosion resistance in simulated body fluid (SBF),... 

    Electrophoretic deposition of chitosan/45S5 Bioglass® composite coatings for orthopaedic applications

    , Article Surface and Coatings Technology ; Volume 205, Issue 23-24 , 2011 , Pages 5260-5268 ; 02578972 (ISSN) Pishbin, F ; Simchi, A ; Ryan, M. P ; Boccaccini, A. R ; Sharif University of Technology
    2011
    Abstract
    This article presents experimental results on the electrophoretic deposition (EPD) of bioresorbable chitosan/45S5 Bioglass® composite coatings for orthopaedic implants based on the Taguchi design of experiments (DOE) approach. The influence of EPD parameters including Bioglass® concentration, electric voltage and deposition time on deposition yield was studied by an orthogonal Taguchi array of L18 type. Multivariate analysis of variance (MANOVA) and regression analysis based on the partial least-square method were used to identify the significant factors affecting the deposition yield and its stability during constant-voltage EPD. The coatings were characterised by high resolution scanning...