    A comparison between the corrosion resistances of High Velocity Oxy Fuel (HVOF) sprayed coatings and hard chromium coatings

    , Article Materials Science Forum, 1 September 2010 through 3 September 2010, Seoul ; Volume 673 , 2011 , Pages 173-178 ; 02555476 (ISSN) ; 9783037850183 (ISBN) Saghi Beyragh, M. R ; Khameneh Asl, S ; Vasfpour, R ; Tazesh, F ; Khallagi, P ; Sharif University of Technology
    2011
    Abstract
    HVOF-sprayed coatings (WC-17%Co) and hard chromium coatings corrosion resistances have been compared through electrochemical polarization test in 3.5% NaCl solution. WC-17%Co alloy coatings were deposited on mild steel substrates by High Velocity Oxy-Fuel (HVOF) spray process. The layers of standard and crack free hard chromium coatings were prepared by using Direct Current (DC) and Pulse Current (PC) electroplating process on the mild steel substrates. Hard chromium coatings was characterized as a reference material, to verify whether HVOF-sprayed coatings are suitable as a hard chromium coatings replacement. The microstructure of the coatings was examined by OM, SEM and XRD. Standard hard...