Loading...
Search for: dental-alloys
0.006 seconds

    Single and double stage sintering of mechanically alloyed powder for nanostructured Ti6Al4V foams usable in cancellous scaffolds

    , Article International Heat Treatment and Surface Engineering ; Volume 7, Issue 1 , 2013 , Pages 43-48 ; 17495148 (ISSN) Sadrnezhaad, S. K ; Aryana, M ; Hassanzadeh Nemati, N ; Alizadeh, M ; Ebadifar, A ; Sharif University of Technology
    2013
    Abstract
    Mechanical alloying and sintering were used to fabricate nanostructured Ti6Al4V scaffolds of highly controllable pore geometry and fully interconnected porous network. Elemental powders were milled for different periods of time (10, 20, 30, 40 and 60 h), mixed with 40-60 vol.-% of 200-400 μm cuboidal NaCl, compacted at 500-600 MPa and sintered according to single or double stage heat treatment regimes at 790 and 950°C under vacuum. After sintering, the samples were soaked in distilled water to washout the NaCl. Foamy microstructures were obtained showing well shaped biopores and fragmentary embedded micropores. The shape of initial NaCl was copied into the biopores which had highly... 

    Effect of localized corrosion on the galvanic corrosion of nitinol and dental alloys

    , Article Anti-Corrosion Methods and Materials ; Volume 56, Issue 6 , 2009 , Pages 323-329 ; 00035599 (ISSN) Afshar, A ; Shirazi, M ; Rahman, M ; Fakheri, E ; Aref, M. R
    2009
    Abstract
    Purpose: The purpose of this paper is to evaluate the galvanic corrosion of nitinol orthodontic wires with six dental alloys in artificial saliva and consider the effect of initiated localized corrosion and real surfaces of anode and cathode on galvanic current. Design/methodology/approach: Linear polarization and cyclic polarization curves for each alloy in de-aerated Duffo and Castillo's artificial saliva are obtained. Galvanic corrosion investigation is conducted by polarization curve intersection and mixed potential theory methods. In order to verify the initiation of localized corrosion, scanning electron microscopy is used. Findings: Initiation of localized corrosion on the anode... 

    Laser textured novel patterns on Ti6Al4V alloy for dental implants surface improvement

    , Article Journal of Laser Applications ; Volume 33, Issue 4 , 2021 ; 1042346X (ISSN) Dabbagh, G. R ; Sadrnezhaad, S. K ; Shoja Razavi, R ; Nourbakhsh, A. A ; Hassanzadeh Nemati, N ; Sharif University of Technology
    Laser Institute of America  2021
    Abstract
    Creating laser texture on dental implants is a novel method for accelerating osseointegration and prolongation of lifespan. The purpose of this research was twofold: (1) Creating intersecting lines pattern with different angles (0°, 15°, 30°, 45°, 60°, 75°, and 90°) on the surface of Ti6Al4V, using pulse Nd:YAG laser with a wavelength of 1064 nm and a pulse length of 170 ns and (2) comparing optical and SEM images, EDS analyses, contact angles (CAs), and surface free energies (FEs) for different intersecting lines angles. CA and FE depended on the intersecting lines angle according to Y = Y 0 + A sin (x B + C), where Y is the CA or FE; x is the intersecting lines angle; and Y0, A, B, and C... 

    Processing and microstructure of Ti-Cu binary alloys: A comprehensive review

    , Article Progress in Materials Science ; Volume 127 , 2022 ; 00796425 (ISSN) Akbarpour, M.R ; Mirabad, H. M ; Hemmati, A ; Kim, H. S ; Sharif University of Technology
    Elsevier Ltd  2022
    Abstract
    Titanium alloys are widely used in various areas, particularly in medical and dental industries, due to their remarkable properties. Still, the optimum cutting conditions for titanium alloys are under consideration. Ti alloyed with Cu has been reported to provide unique properties such as good mechanical performance, good biocompatibility, acceptable corrosion resistance, and relatively lower melting point. The properties of Ti-Cu alloys mentioned above are sensitive to microstructure. They are highly dependent on microstructural characteristics such as the formation, growth, and morphological features of intermetallics and precipitates, dependent on the amount of Cu and the manufacturing... 

    Porous shape memory dental implant by reactive sintering of TiH2–Ni-Urea mixture

    , Article Materials Science and Engineering C ; Volume 107 , 2020 Akbarinia, S ; Sadrnezhaad, S .K ; Hosseini, S. A ; Sharif University of Technology
    Elsevier Ltd  2020
    Abstract
    We produced bifurcated bone-like shape memory implant (BL-SMI) with desirable tooth-root fixation capability by compact-sintering of TiH2–Ni-urea mixture. The primary constituents of the porous product were Ni and Ti. We could adjust the pores' shape, size, and interconnectivity for favorite bone ingrowth by using urea as a space holder. Without urea, we obtained an average porosity of 0.30, and a mean void size of 100 μm. With 70 vol % urea, we got 62% interconnected pores of 400 μm average size. Aging allowed us to tune the austenite-martensite transformation temperatures towards the needed body tissue arouse. Differential scanning calorimetry measured the transformation temperatures....