    Slip velocity in pulsed disc and doughnut extraction columns

    , Article Chemical Industry and Chemical Engineering Quarterly ; Volume 17, Issue 3 , 2011 , Pages 333-339 ; 14519372 (ISSN) Torab Mostaedi, M ; Jalilvand, H ; Outokesh, M ; Sharif University of Technology
    2011
    Abstract
    In the present work, slip velocity has been measured in a 76 mm diameter pulsed disc and doughnut extraction column for four different liquid-liquid systems. The effects of operating variables including pulsation intensity and dispersed and continuous phase flow rates on slip velocity have been investigated. The existence of three different operational regimes, namely mixersettler, transition, and emulsion regimes, was observed when the energy input was changed. Empirical correlations are derived for prediction of the slip velocity in terms of operating variables, physical properties of the liquid systems, and column geometry for different regimes. Good agreement between prediction and... 

    Study of Dispersed Phase Holdup and Slip Velocity in a Pulsed Disc and Doughnut Extraction Column

    , M.Sc. Thesis Sharif University of Technology Jalilvand, Hossein (Author) ; Outukesh, Mohammad (Supervisor) ; Torab Mostaedi, Meisam (Supervisor)
    Abstract
    Dispersed phase holdup has been measured in a 75 mm diameter pulsed disc and doughnut extraction column for three different liquid-liquid systems. The effects of operational variables such as pulsation intensity and dispersed and continuous phases flow rates on holdup have been investigated and found to be significant. The existence of three different operational regimes, namely mixer-settler, dispersion, and emulsion regimes, was observed when the energy input was changed. The results indicated that the characteristic velocity approach is applicable to this type of extraction column for analysis holdup in transition and emulsion regions. Empirical correlations are derived for prediction of... 

    Study on Continuous Phase Holdup in a Pulsed Disc and Doughnut Extraction Column by Radiotracer Technique

    , M.Sc. Thesis Sharif University of Technology Yaghoubi, Yaser (Author) ; Outokesh, Mohammad (Supervisor) ; Tabasi, Mohsen (Supervisor) ; Mostaedi, M.T (Co-Advisor)
    Abstract
    The dispersed phase holdup is one of the important parameters in the design pulsed column and set the column diameter, height and characteristics of flooding and mass transfer. High efficiency and low space requirements of these columns cause is particularly in the nuclear industry, Due to the possible presence of radiation and the need for protection against radiation, considered and used. In this project, the dispersed phase holdup and mean residence time in a pulsed disc and donut column in a semi-industrial scale using radiotracer and shut down methods compared and presented for water-kerosene system. Also axial dispersion coefficient in the column using radiotracer methods is calculated... 

    Dispersed phase holdup in a pulsed disc and doughnut extraction column

    , Article Brazilian Journal of Chemical Engineering ; Volume 28, Issue 2 , June , 2011 , Pages 313-323 ; 01046632 (ISSN) Torab Mostaedi, M ; Jalilvand, H ; Outokesh, M ; Sharif University of Technology
    2011
    Abstract
    Dispersed phase holdup has been measured in a 76 mm diameter pulsed disc and doughnut extraction column for three different liquid-liquid systems. The effects of operational variables such as pulsation intensity and dispersed and continuous phase flow rates on holdup have been investigated and found to be significant. The existence of three different operational regimes, namely mixer-settler, dispersion, and emulsion regimes, was observed when the energy input was changed. The results indicated that the characteristic velocity approach is applicable to this type of extraction column for analysis of holdup in the transition and emulsion regions. Empirical correlations are derived for...