Loading...
Search for: electrospray-ionization
0.005 seconds

    Generation of arylnitrenium ions by nitro-reduction and gas-phase synthesis of N-heterocycles

    , Article Journal of the American Society for Mass Spectrometry ; Volume 15, Issue 11 , 2004 , Pages 1675-1688 ; 10440305 (ISSN) Chen, H ; Chen, H ; Cooks, R. G ; Bagheri, H ; Sharif University of Technology
    2004
    Abstract
    Nitro-reduction by the vinyl halide radical cation CH 2 = CH-X +· (X = Cl or Br) converts nitroaromatics into arylnitrenium ions, significant intermediates in carcinogenesis, and the present study reports on the scope and regioselectivity of this versatile reaction. The reaction is general for different kinds of substituted nitroaromatics; para/meta substitutents have little effect on the reaction while ortho substitutents result in low yields of arylnitrenium ions. The phenylnitrenium ion PhNH + can be generated by chemical ionization (CI) of nitrobenzene using 1,2-dichloroethane as the reagent gas or by atmospheric pressure chemical ionization (APCI) of 1,2-dichloroethane solution doped... 

    Solution structure of a seven coordinated manganese(II) complex via electrospray ionization mass spectrometry

    , Article Spectrochimica Acta - Part A: Molecular and Biomolecular Spectroscopy ; Volume 75, Issue 3 , 2010 , Pages 1168-1170 ; 13861425 (ISSN) Najafpour, M. M ; Boghaei, D. M ; Sjöberg, P. J. R ; Sharif University of Technology
    2010
    Abstract
    The mononuclear complex [Mn(tptz)(CH3COO)(OH2)2]NO3 (1) was investigated by electrospray ionization mass spectrometry in aqueous solution at pH 4.5. Electrospray ionization mass spectrometry shows that mononuclear and dinuclear manganese cationic species are present in solution, probably in equilibrium with neutral 1. An experiment showed that the most important reaction in the presence of oxone (2KHSO5·KHSO4·K2SO4) is decoordination  

    Through-space electronic communication of zinc phthalocyanine with substituted [60]Fullerene bearing O2Nxaza-crown macrocyclic ligands

    , Article Spectrochimica Acta - Part A: Molecular and Biomolecular Spectroscopy ; Volume 171 , 2017 , Pages 330-339 ; 13861425 (ISSN) Ghanbari, B ; Shahhoseini, L ; Mahlooji, N ; Gholamnezhad, P ; Taheri Rizi, Z ; Sharif University of Technology
    Elsevier B.V  2017
    Abstract
    Two new macrocyclic ligands containing 17- and 19-membered O2N3-donor aza-crowns anchored to [60]Fullerene were synthesized and characterized by employing HPLC, electrospray ionization mass (ESI-MS), 1H and 13C NMR, UV–vis, IR spectroscopies, as well as powder X-ray diffraction (PXRD) and thermogravimetric analysis (TGA) in solid state. TGA measurements revealed that upon linking each of these macrocycle rings to [60]Fullerene, the decomposition point measured for [60]Fullerene moiety was increased, indicating on the promoted stability of [60]Fullerene backbone during binding to these macrocyclic ligands. Moreover, the ground state non-covalent interactions of [60]Fullerene derivatives of... 

    Analysis of alternative new pesticide (fluopyram, flupyradifurone, and indaziflam) residues in pistachio, date, and soil by liquid chromatography triple quadrupole tandem mass spectrometry

    , Article Soil and Sediment Contamination ; Volume 30, Issue 4 , 2021 , Pages 373-383 ; 15320383 (ISSN) Mahdavi, V ; Keikavousi Behbahan, A ; Moradi, F ; Aboul Enein, H. Y ; Sharif University of Technology
    Bellwether Publishing, Ltd  2021
    Abstract
    Fluopyram, flupyradifurone, and indaziflam are novel systemic pesticides developed by Bayer. Based on available data, these pesticides appears to have a favorable safety profile in the case of pesticide residue problems. Herein, we report an effective analytical method for the determination of novel pesticides were developed using ultra-high performance liquid chromatography with tandem mass spectrometry coupled with a quick, easy, cheap, effective, rugged, and safe procedure. These target compounds were extracted with acetonitrile and cleaned up with PSA, and were separated successfully between 10.2 and 18.3 min using a C18 chromatographic column connected to an electrospray ionization... 

    Self-modeling curve resolution techniques applied to comparative analysis of volatile components of Iranian saffron from different regions

    , Article Analytica Chimica Acta ; Volume 662, Issue 2 , 2010 , Pages 143-154 ; 00032670 (ISSN) Jalali Heravi, M ; Parastar, H ; Ebrahimi Najafabadi, H ; Sharif University of Technology
    Abstract
    Volatile components of saffron from different regions of Iran were extracted by ultrasonic-assisted solvent extraction (USE) and were analyzed by gas chromatography-mass spectrometry (GC-MS). Self-modeling curve resolution (SMCR) was proposed for resolving the co-eluted GC-MS peak clusters into pure chromatograms and mass spectra. Multivariate curve resolution-objective function minimization (MCR-FMIN) and multivariate curve resolution-alternating least square (MCR-ALS) were successfully used for this purpose. The accuracy of the qualitative and quantitative results was improved considerably using SMCR techniques. Comparison of the results of saffron from different regions of Iran showed... 

    Modeling and optimization of gelatin-chitosan micro-carriers preparation for soft tissue engineering: using response surface methodology

    , Article Materials Science and Engineering C ; Volume 75 , 2017 , Pages 545-553 ; 09284931 (ISSN) Radaei, P ; Mashayekhan, S ; Vakilian, S ; Sharif University of Technology
    Abstract
    Electrospray ionization is a wide spread technique for producing polymeric microcarriers (MCs) by applying electrostatic force and ionic cross-linker, simultaneously. In this study, fabrication process of gelatin-chitosan MCs and its optimization using the Response Surface Methodology (RSM) is reported. Gelatin/chitosan (G/C) blend ratio, applied voltage and feeding flow rate, their individual and interaction effects on the diameter and mechanical strength of the MCs were investigated. The obtained models for diameter and mechanical strength of MCs have a quadratic relationship with G/C blend ratio, applied voltage and feeding flow rate. Using the desirability curve, optimized G/C blend...