Simulation and exergy-method analysis of an industrial refrigeration cycle used in NGL recovery units
, Article International Journal of Energy Research ; Volume 30, Issue 15 , 2006 , Pages 1336-1351 ; 0363907X (ISSN) ; Jarrahian, A ; Pishvaie, M. R ; Sharif University of Technology
2006
Abstract
The behaviour of an industrial refrigeration cycle with refrigerant propane has been investigated by the exergy method. An natural gas liquid recovery unit with its refrigeration cycle has been simulated to prepare the exergy analysis. Using a typical actual work input value; the exergetic efficiency of the refrigeration cycle is determined to be 26.51 % indicating a great potential for improvements. The obtained simulation results reveal that the exergetic efficiencies of the air cooler(s) and chilling sections get the lowest rank among the other compartments of refrigeration cycle. Refrigeration calculations have been carried out through the analysis of T-S and P-H diagrams where...