Loading...
Search for: femoral-artery
0.004 seconds

    Effects of Crimping on Mechanical Performance of Nitinol Stent Designed for Femoral Artery: Finite Element Analysis [electronic resource]

    , Article Journal of Materials Engineering and Performance ; November 2013, Volume 22, Issue 11, pp 3228-3236 Nematzadeh, F. (Fardin) ; Sadrnezhaad, K ; Sharif University of Technology
    Abstract
    Nitinol stents are used to minimize improper dynamic behavior, low twistability, and inadequate radial mechanical strength of femoral artery stents. In this study, finite element method is used to investigate the effect of crimping and Austenite finish temperature (A f) of Nitinol on mechanical performance of Z-shaped open-cell femoral stent under crimping conditions. Results show that low A f Nitinol has better mechanical and clinical performance due to small chronic outward force, large radial resistive force, and appropriate superelastic behavior  

    Effects of crimping on mechanical performance of nitinol stent designed for femoral artery: Finite element analysis

    , Article Journal of Materials Engineering and Performance ; Volume 22, Issue 11 , 2013 , Pages 3228-3236 ; 10599495 (ISSN) Nematzadeh, F ; Sadrnezhaad, S. K ; Sharif University of Technology
    2013
    Abstract
    Nitinol stents are used to minimize improper dynamic behavior, low twistability, and inadequate radial mechanical strength of femoral artery stents. In this study, finite element method is used to investigate the effect of crimping and Austenite finish temperature (A f) of Nitinol on mechanical performance of Z-shaped open-cell femoral stent under crimping conditions. Results show that low A f Nitinol has better mechanical and clinical performance due to small chronic outward force, large radial resistive force, and appropriate superelastic behavior  

    The effect of temperature on eccentric contraction-induced isometric force loss in isolated perfused rat medial gastrocnemius muscle

    , Article Tehran University Medical Journal ; Volume 66, Issue 6 , 2008 , Pages 388-395 ; 16831764 (ISSN) Vasaghi Gharamaleki, B ; Keshavarz, M ; Gharibzadeh, S ; Marvi, H ; Mosayebnejad, J ; Ebrahimi Takamjani, E ; Sharif University of Technology
    Tehran University of Medical Sciences  2008
    Abstract
    Background: The typical features of eccentric exercise-induced muscle damage are delayed-onset muscle soreness (DOMS) and prolonged loss of muscle strength. It has been shown that passive warmth is effective in reducing muscle injury. Due to the interaction of different systems in vivo, we used isolated perfused medial gastrocnemius skeletal muscle to study the direct effect of temperature on the eccentric contraction-induced force loss. Methods: After femoral artery cannulation of a rat, the left medial gastrocnemius muscle was separated and then the entire lower limb was transferred into a prewarmed (35oC) chamber. With the chamber temperature at 31, 35 and 39oC before and during eccentric... 

    Effects of material properties on mechanical performance of Nitinol stent designed for femoral artery: Finite element analysis

    , Article Scientia Iranica ; Volume 19, Issue 6 , December , 2012 , Pages 1564-1571 ; 10263098 (ISSN) Nematzadeh, F ; Sadrnezhaad, S. K ; Sharif University of Technology
    2012
    Abstract
    The Finite element method was used for evaluation of the effects of material properties on the mechanical performance of the new geometry designed for the Z-shaped open-cell femoral artery self-expanding stent, made of Nitinol wire, by application of crushing force. The behavior of the stents, having two sets of properties, was compared. The stents with higher Af temperature show better clinical behavior due to lower chronic outward force, higher radial resistive strength and more suitable superelastic behavior. Model calculations show that a large change of Af temperature could exert a substantial effect on the practical performance of the stent