Loading...
Search for: flexible-composites
0.004 seconds

    Synergy of titanium dioxide nanotubes and polyurethane properties for bypass graft application: Excellent flexibility and biocompatibility

    , Article Materials and Design ; Volume 215 , 2022 ; 02641275 (ISSN) Kianpour, G ; Bagheri, R ; Pourjavadi, A ; Ghanbari, H ; Sharif University of Technology
    Elsevier Ltd  2022
    Abstract
    A flexible, porous and biocompatible titanium dioxide nanotubes (TNT) - polyurethane (PU) film has been produced as a new scaffold for artificial vascular grafts. Synergistic improvements in the properties of vertical TNT and PU was reached, including enhancements in their biocompatibility, mechanical strength, flexibility and porosity. Open-ended (OE) TNT-PU and close-ended (CE) TNT-PU films were synthesized and their mechanical and biological properties were compared with their pure PU counterparts. TNT were attached to PU with a new strategy. The resulting flexible structure was hydrophilic and super hydrophilic in OE-TNT-PU and CE-TNT-PU scaffolds, respectively. The gas leakage during... 

    Characterization of constrained aged niti strips for using in artificial muscle actuators

    , Article International Journal of Engineering, Transactions A: Basics ; Volume 24, Issue 4 , 2011 , Pages 321-329 ; 17281431 (ISSN) Hassanzadeh Nemati, N ; Sadrnezhaad, S. K ; Sharif University of Technology
    Abstract
    Marvelous bending/straightening effects of two-way shape memory alloy (TWSMA) help their employment in design and manufacturing of new medical appliances. Constrained ageing with bending load scheme can induce two-way shape memory effect (TWSME). Scanning electron microscopic (SEM) analysis, electrical resistivity measurement (ERM) and differential scanning calorimetry (DSC) are employed to determine the property change due to flat strip constrained aging. Results show that flat-annealing prior to the aging shifts NiTi transformations temperatures to higher values. Superelastic behavior of the as-received/flat- annealed/aged samples with more adequate transition temperatures due to... 

    Improved adhesion of NiTi wire to silicone matrix for smart composite medical applications

    , Article Materials and Design ; Volume 30, Issue 9 , 2009 , Pages 3667-3672 ; 02641275 (ISSN) Sadrnezhaad, Kh ; Hassanzadeh Nemati, N ; Bagheri, R ; Sharif University of Technology
    2009
    Abstract
    Recent uses of intelligent composites in biomedical appliances aggrandize the necessity of bonding-strength improvement in NiTi/silicone matrix interface. SEM micrographs and pull-out tests are employed to determine the strength of the NiTi/silicone bonds in a flexible composite piece. Greater adhesion strengths are obtained due to the presence of thin oxide layer, surface roughness and frictional forces between the embedded-wires and the contacting phase. Effect of curing treatment on phase transformation temperatures of the wires is determined by electrical resistivity (ER) measurements. Results show that the curing treatment shifts the transition points of the wires towards higher...