Loading...
Search for: gait-parameters
0.008 seconds

    Design and Implementation of a GAIT Analysis System Using Kinect for Clinical Application

    , M.Sc. Thesis Sharif University of Technology Jamali Soosefi, Zahra (Author) ; Behzadipour, Saeed (Supervisor)
    Abstract
    To date various commercial systems were used in the gait analysis area. These systems have some difficulties for clinical use, such as being indwell, making trouble in movement and high prices. The Kinect sensor does not have problems of these systems. If the error of sensor is acceptable, Kinect sensor is a suitable choice for application in clinics. The possibility of utilization of the Kinect sensor as a gait analysis system has been studied in this research. The sensor errors in calculation of gait parameters such as lower limb joints angle, stride time, stride length and spatial coordinates of joints were computed. In previous researches the Kinect sensor error has been calculated for... 

    Quantitative evaluation of parameters affecting the accuracy of Microsoft Kinect in GAIT analysis

    , Article 2016 23rd Iranian Conference on Biomedical Engineering and 2016 1st International Iranian Conference on Biomedical Engineering, ICBME 2016, 23 November 2016 through 25 November 2016 ; 2017 , Pages 306-311 ; 9781509034529 (ISBN) Jamali, Z ; Behzadipour, S ; Sharif University of Technology
    Abstract
    To date various commercial systems have been used in the GAIT analysis. These systems have some difficulties for clinical use, such as interfering with normal movement and high prices. The possibility of utilization of Kinect as a sensor for GAIT analysis has been studied in this research. The accuracy of Kinect in calculation of GAIT parameters such as lower limb joint angles, stride time, and stride length were computed during normal walking. The effects of the sensor's position and direction relative to the walkway were also investigated. The Kinect sensor was installed at different positions toward the motion path. In each position the data was recorded by both Kinect and a commercial... 

    vThe effect of saddle-assistive device on improving the gait parameters of patients with the lower limbs weakness: a pilot study

    , Article Journal of Bionic Engineering ; Volume 17, Issue 6 , 2020 , Pages 1175-1185 Hojjati Najafabadi, A ; Amini, S ; Farahmand, F ; Sharif University of Technology
    Springer  2020
    Abstract
    To help walking, using assistive devices can be considered to reduce the loads caused by weight and to effectively decrease the propulsive forces. In this study, a mobility Saddle-Assistive Device (S-AD) supporting body weight while walking was evaluated on two healthy volunteers. This device is based on the support of body weight against gravity with the help of a saddle, which is not used in other passive mobility assistive devices. To prove the efficiency of this device, the experimental results obtained while walking with this device were compared with those related to walking without the assistive device. The results showed that this device could significantly reduce the forces and...