    Gusset Plate Connectionmodels

    , M.Sc. Thesis Sharif University of Technology Monjezi, Ahmad (Author) ; Maleki, Shervin (Supervisor)
    Abstract
    Lateral forces on structures are transferred to braces as tensile and compressive loads. These loads enter the beams and columns through the gusset plates. The gusset connections to the beams and columns must be such that they be able to pass the loads through themselves. So far, five analytical models have been proposed for this connection and only one of them is recommended by AISC. These models estimate the existing forces and moments on the connection. The analytical models are: model 1 (KISS), model 2 (2A-AISC), model 3 (Thornton), model 4 (Ricker) and model 5 (Richard). Among these models, only model 3 is recommended by AISC because the others are more conservative. It should be noted...