Loading...
Search for: high-stability
0.005 seconds

    Electrodeposited polyaniline on Pd-loaded TiO2 nanotubes as active material for electrochemical supercapacitor

    , Article Journal of Electroanalytical Chemistry ; Volume 691 , 2013 , Pages 51-56 ; 15726657 (ISSN) Gobal, F ; Faraji, M ; Sharif University of Technology
    2013
    Abstract
    PANI/Pd/TiO2NTs electrodes with highly porous structures and good capacitive characteristics were prepared by electrodeposition of polyaniline on palladium nanoparticles loaded TiO2 nanotubes. The loading of small palladium nanoparticles was carried out by sonochemical reduction of Pd+2 onto TiO2NTs and affected the ordered growth of PANI, reducing the charge transfer resistance and increasing surface area of PANI. The specific capacitance and the stability of electrode showed improvements. The results illustrated that the specific capacitance of these electrodes was around 1060 F g-1 in 1.0 M H2SO4 electrolyte as measured at a constant current of 2.0 A g-1, whereas it was 210 F g-1 for the... 

    Template-based electrodeposition of Pt/Ni nanowires and its catalytic activity towards glucose oxidation

    , Article Electrochimica Acta ; Volume 58, Issue 1 , 2011 , Pages 551-555 ; 00134686 (ISSN) Mahshid, S. S ; Mahshid, S ; Dolati, A ; Ghorbani, M ; Yang, L ; Luo, S ; Cai, Q ; Sharif University of Technology
    2011
    Abstract
    An electro-catalysis non-enzymatic electrode is proposed based on alloyed Pt/Ni nanowire arrays (NWAs) for the detection of glucose. The Pt/Ni NWAs were prepared by pulse electrodeposition of Pt and Ni within a nano-pore polycarbonate (PC) membrane followed by a chemical etching of the membrane. The electrode structure is characterized by scanning electron microscopy (SEM) and transmission electron microscopy (TEM). The resulting Pt/Ni NWAs electrode shows high electrocatalytic activities towards the oxidation of glucose in alkaline solution. Consequently, a sensitive amperometric detection of glucose is achieved under 0.45 V vs. SCE with a low detection limit of 1.5 μM within a wide linear... 

    Hole transport material based on modified N-annulated perylene for efficient and stable perovskite solar cells

    , Article Solar Energy ; Volume 194 , 2019 , Pages 279-285 ; 0038092X (ISSN) Sheibani, E ; Amini, M ; Heydari, M ; Ahangar, H ; Keshavarzi, R ; Zhang, J ; Mirkhani, V ; Sharif University of Technology
    Elsevier Ltd  2019
    Abstract
    N-annulated perylene based materials show outstanding and tunable optical and physical properties, making them suitable to be charge transport materials for optoelectronic applications. However, this type of materials has so far not been well studied in solar cells. Here, we develop a new hole transport material (HTM), namely S5, based on perylene building block terms, for organic-inorganic hybrid perovskite solar cells (PSCs). We have systematically studied the influences of the film thickness of S5 on their photovoltaic performance, and a low concentration of S5 with a thinner HTM film is favorable for obtaining higher solar cell efficiency. S5 shows excellent energy alignment with... 

    Application of carbon nanoparticle/chitosan modified electrode for the square-wave adsorptive anodic striping voltammetric determination of Niclosamide

    , Article Electrochemistry Communications ; Volume 12, Issue 1 , 2010 , Pages 66-69 ; 13882481 (ISSN) Ghalkhani, M ; Shahrokhian, S ; Sharif University of Technology
    2010
    Abstract
    A new modified electrode formed by carbon nanoparticle/chitosan film (CNP/CS) was used for electrocatalytic reduction of Niclosamide (NA). The electrochemical behavior of NA at the CNP/CS modified electrode was investigated in detail by the means of cyclic voltammetry. The reduction mechanism of NA, corresponds to the redox chemistry of nitro group, was thoroughly investigated. The effect of the experimental parameters e.g. potential and time of accumulation, pH of the buffered solutions and potential sweep rate on the response of the electrode was studied. The prepared electrode showed high stability and uniformity in the composite film, short response time, good reproducibility and an... 

    Multi-walled carbon nanotubes with immobilised cobalt nanoparticle for modification of glassy carbon electrode: Application to sensitive voltammetric determination of thioridazine

    , Article Biosensors and Bioelectronics ; Volume 24, Issue 11 , 2009 , Pages 3235-3241 ; 09565663 (ISSN) Shahrokhian, S ; Ghalkhani, M ; Adeli, M ; Amini, M. K ; Sharif University of Technology
    2009
    Abstract
    Multi-walled carbon nanotubes (MWCNTs) were immobilised with cobalt nanoparticles and analyzed by transmission electron microscopy. This modification procedure substantially improved colloidal dispersion of the immobilised MWCNTs in water and organic solvents, yielding uniform and stable thin films for modification of the glassy carbon electrode surface. The modified electrode showed an efficient catalytic role for the electrochemical oxidation of thioridazine (TR), leading to remarkable decrease in its oxidation overpotential of approximately 100 mV and enhancement of the kinetics of the electrode reaction, which can be confirmed by increasing in the peak current and sharpness of the peak....