    A comparison between partial discharge propagation in multiple-α and single-α transformer winding

    , Article Electrical Insulation Conference and Electrical Manufacturing Expo, 2005, Indianapolis, IN, 23 October 2005 through 26 October 2005 ; Volume 2005 , 2005 , Pages 108-111 ; 0780391454 (ISBN); 9780780391451 (ISBN) Naderi, M. S ; Vakilian, M ; Blackburn, T. R ; Phung, B.T ; Zhang, H ; Nam O, H ; Naderi, M. S ; Sharif University of Technology
    2005
    Abstract
    Power transformers are in service in different environmental, electrical and mechanical conditions. Many experiences have proved that the inner insulation system degradation may pose the transformer to fail while in service. On the other hand, partial discharges (PD) are recognized as the main cause of insulation deterioration process. Therefore, reaching the optimum inner insulation system is one of the challenges a transformer designer is faced with. The solution lies in the correct and accurate modelling of different types of transformer windings. Transformer strength especially during transient conditions is a criterion for transformer insulation designers. This challenge has made... 

    A method for studying partial discharges location and propagation within power transformer winding based on the structural data

    , Article 2005 International Symposium on Electrical Insulating Materials, ISEIM 2005, Kitakyushu, 5 June 2005 through 9 June 2005 ; Volume 2 , 2005 , Pages 490-493 Naderi, M. S ; Vakilian, M ; Blackburn, T. R ; Phung, B. T ; Zhang, H ; Naderi, M. S ; Sharif University of Technology
    Institute of Electrical Engineers of Japan  2005
    Abstract
    Power transformer inner insulation system is a very critical component. Its degradation may pose apparatus to fail while in service. On the other hand, experimental experiences prove that partial discharges are a major source of insulation failure in power transformers. If the deterioration of the insulation system caused by PD activity can be detected at an early stage, preventive maintenance measures may be taken. Because of the complex structure of the transformer, accurate PD location is difficult and is one of the challenges power utilities are faced with. This problem comes to be vital in open access systems. In this paper a theory for locating partial discharge and its propagation... 

    Transformer components impact on compatibility of measured PDs: Comparison of IEC60270 and RF methods

    , Article High Voltage ; Volume 4, Issue 1 , 2019 , Pages 33-40 ; 23977264 (ISSN) Firuzi, K ; Vakilian, M ; Toan Phung, B ; Blackburn, T ; Sharif University of Technology
    Institution of Engineering and Technology  2019
    Abstract
    Power transformer partial discharge signal measurement using Radio Frequency method has advantages over IEC 60270 'apparent charge' measurement method for online monitoring due to greater immunity against external interference. However, the lack of a well-defined calibration relationship between the two methods is main disadvantage of RF method. Simultaneous measurements, using these two methods, carried out on various transformer PD source models, in laboratory, to investigate main parameters that affect the relationship of results of these two methods. In this paper, factors that influence this relationship are classified into three groups: (i) type of PD sources, (ii) transformer windings... 

    Optimization of HV generator insulation system based on electro-thermal analysis using FEM

    , Article Proceedings of the IASTED International Conference on Modelling and Simulation ; 2011 , Pages 288-293 ; 10218181 (ISSN) ; 9780889868878 (ISBN) Azizi, D ; Gholami, A ; Gholami, M. H ; Sharif University of Technology
    Abstract
    A large number of generators failed due to stator winding problems, mainly insulation deterioration. Insulation degradation assessment plays vital role in the asset life management. Electro thermal analysis is the main characteristic for simulation of generator behavior and to improve the design of stator slot's insulation. Dielectric parameters such as insulation thickness, spacing, material types, geometry of winding and slot are major design consideration. A very powerful method available to analyze electro thermal performance is Finite Element Method (FEM) which is used in this paper. The analysis of various stator coil and slot configurations are used to design the better dielectric...