Loading...
Search for: international-standards
0.009 seconds

    Design of linear anti-scatter grid geometry with optimum performance for screen-film and digital mammography systems

    , Article Physics in Medicine and Biology ; Volume 60, Issue 15 , July , 2015 , Pages 5753-5765 ; 00319155 (ISSN) Khodajou Chokami, H ; Sohrabpour, M ; Sharif University of Technology
    Institute of Physics Publishing  2015
    Abstract
    A detailed 3D Monte Carlo simulation of the grid geometrical parameters in screen-film mammography (SFM) and digital mammography (DM) systems has been performed. A combination of IEC 60627:2013 international standard conditions and other more clinically relevant parameters were used for this simulation. Accuracy of our results has been benchmarked with previously published data and good agreement has been obtained. Calculations in a wide range of linear anti-scatter grid geometries have been carried out. The evaluated parameters for the SFM system were the Bucky factor (BF) and contrast improvement factor (CIF) and for the DM system it was signal differenceto- noise ratio improvement factor... 

    Consumption criteria and energy labeling of wet cooling towers in Iran

    , Article 2009 ASME Power Conference, 21 July 2009 through 23 July 2009 ; 2009 , Pages 153-157 ; 9780791843505 (ISBN) Sajadi, B ; Sayyadi, P ; Saidi, M. H ; Sharif University of Technology
    Abstract
    Increasing concerns about global warming and environmental pollution control has pushed the relevant organizations to set regulations and to develop programs for energy saving. In addition, for many high energy using appliances, energy labeling provides the end user with important data to select energy-efficient equipments and encourage the manufacturers to enhance the performance of their productions. In this research, a new energy-saving program for wet cooling towers has been developed. Considering a thermo-hydraulic analysis, a novel Energy Index (IE) has been extracted which takes all aspects of the problem into account. The present index can be used as a proper criterion for energy... 

    Neutron spectroscopy with soft computing: Unfolding of the neutron energy spectrum using the developed computer code based on Adaptive Group of Ink Drop Spread (AGIDS)

    , Article Journal of Instrumentation ; Volume 14, Issue 3 , 2019 ; 17480221 (ISSN) Hosseini, S. A ; Sharif University of Technology
    Institute of Physics Publishing  2019
    Abstract
    This paper presents the developed computer codes based on the Adaptive Group of Ink Drop Spread (AGIDS) algorithm [1] for the reconstruction of the energy spectrum of the neutron source. The required data are generated via simulation of the neutron pulse height distributions due to randomly generated energy spectra with the MCNPX-ESUT computer code [2]. The simulated neutron pulse height distributions and corresponding randomly generated energy spectra are the input and output data of the developed computer code, respectively. As a case study, the 241Am-9Be neutron source is studied and the simulation of the neutron pulse height distribution of the NE-213 liquid organic scintillator is... 

    Optimization of dispersive liquid-liquid microextraction and improvement of detection limit of methyl tert-butyl ether in water with the aid of chemometrics

    , Article Journal of Chromatography A ; Volume 1217, Issue 45 , November , 2010 , Pages 7017-7023 ; 00219673 (ISSN) Karimi, M ; Sereshti, H ; Samadi, S ; Parastar, H ; Sharif University of Technology
    2010
    Abstract
    Dispersive liquid-liquid microextraction (DLLME) coupled with gas chromatography-mass spectrometry-selective ion monitoring (GC-MS-SIM) was applied to the determination of methyl tert-butyl ether (MTBE) in water samples. The effect of main parameters affecting the extraction efficiency was studied simultaneously. From selected parameters, volume of extraction solvent, volume of dispersive solvent, and salt concentration were optimized by means of experimental design. The statistical parameters of the derived model were R 2=0.9987 and F=17.83. The optimal conditions were 42.0μL for extraction solvent, 0.30mL for disperser solvent and 5% (w/v) for sodium chloride. The calibration linear range... 

    A strategic management model for evaluation of health, safety and environmental performance

    , Article Environmental Monitoring and Assessment ; Volume 184, Issue 5 , 2012 , Pages 2981-2991 ; 01676369 (ISSN) Abbaspour, M ; Toutounchian, S ; Roayaei, E ; Nassiri, P ; Sharif University of Technology
    Abstract
    Strategic health, safety, and environmental management system (HSE-MS) involves systematic and cooperative planning in each phase of the lifecycle of a project to ensure that interaction among the industry group, client, contractor, stakeholder, and host community exists with the highest level of health, safety, and environmental standard performances. Therefore, it seems necessary to assess the HSE-MS performance of contractor(s) by a comparative strategic management model with the aim of continuous improvement. The present Strategic Management Model (SMM) has been illustrated by a case study and the results show that the model is a suitable management tool for decision making in a contract...