Loading...
Search for: limits-of-quantification
0.007 seconds

    Determination and identification of nitroaromatic explosives by a double-emitter sensor array

    , Article Talanta ; Volume 201 , 2019 , Pages 230-236 ; 00399140 (ISSN) Ghasemi, F ; Hormozi Nezhad, M. R ; Sharif University of Technology
    Elsevier B.V  2019
    Abstract
    Detection of nitroaromatic explosives is of strong concern because of human health, public safety, environment, and military issues. In this study, we present a ratiometric sensor array for detection and discrimination of widely-used nitroaromatics (i.e., 2,4,6-trinitrotoluene (TNT), 2,4,6-trinitrophenol (TNP), and 2,4-dinitrotoluene (DNT)). In the design of sensor elements (SE) we employ blue emissive carbon dots (BCDs) in combination with yellow (SE-A) and red (SE-B) emissive cadmium telluride quantum dots (CdTe QDs). The fluorescence intensity of BCDs, YQDs, and RQDs is quenched by TNT, DNT, and TNP in various degrees. Both TNT and TNP cause the quenching and spectral shift of BCDs (TNT... 

    Analysis of alternative new pesticide (fluopyram, flupyradifurone, and indaziflam) residues in pistachio, date, and soil by liquid chromatography triple quadrupole tandem mass spectrometry

    , Article Soil and Sediment Contamination ; Volume 30, Issue 4 , 2021 , Pages 373-383 ; 15320383 (ISSN) Mahdavi, V ; Keikavousi Behbahan, A ; Moradi, F ; Aboul Enein, H. Y ; Sharif University of Technology
    Bellwether Publishing, Ltd  2021
    Abstract
    Fluopyram, flupyradifurone, and indaziflam are novel systemic pesticides developed by Bayer. Based on available data, these pesticides appears to have a favorable safety profile in the case of pesticide residue problems. Herein, we report an effective analytical method for the determination of novel pesticides were developed using ultra-high performance liquid chromatography with tandem mass spectrometry coupled with a quick, easy, cheap, effective, rugged, and safe procedure. These target compounds were extracted with acetonitrile and cleaned up with PSA, and were separated successfully between 10.2 and 18.3 min using a C18 chromatographic column connected to an electrospray ionization... 

    Optimization of Tribenuron-methyl determination by differential pulse polarography using experimental design

    , Article Analytical Methods ; Volume 2, Issue 1 , 2010 , Pages 41-48 ; 17599660 (ISSN) Ahmadi, S ; Ghassempour, A ; Fakhari, A. R ; Jalali Heravi, M ; Aboul Enein, H. Y ; Sharif University of Technology
    Abstract
    Differential pulse polarography (DPP) was applied for the determination of the herbicide Tribenuron-methyl (TBM). This is a first study for various parameters affecting the reduction peak current were simultaneously optimized using experimental design and these results are different from other reports. The effect of factors such as voltage step, voltage step time, pulse amplitude, pulse time, sample pH, concentration of the supporting electrolyte and the mercury drop size were assessed by means of a (27-2) fractional factorial design. It was found that the effects and interactions of four out of seven factors were significant. Consequently, a central composite design (CCD) with four factors,... 

    Electrospun decyl-3-methylimidazolium mono bromate/polyamide nanofibers as solid-phase microextraction coating

    , Article Journal of Chromatography A ; Volume 1516 , 2017 , Pages 35-41 ; 00219673 (ISSN) Roostaie, A ; Rastegar, S ; Najarzadegan, H ; Ehteshami, S ; Sharif University of Technology
    Abstract
    In the current study, electrospun-based ionic liquid (IL) doped polyamide (PA) nanofibers were prepared and used as the coating material of solid phase microextration device in the fiber geometry. Addition of IL, decyl-3-methylimidazolium mono bromate, increased the conductivity of the PA solution facilitating the electrospining process. The scanning electron microscopy images of decyl-3-methylimidazolium mono bromated/polyamide nanofibers showed the decreased diameter of the nanofibers in the range of 35–160 nm compared to the PA nanofiber. The factors affecting the structure of nanofibers (e.g. ratio of decyl-3-methylimidazolium mono bromate to PA, coating time and applied voltage) were... 

    Polyaniline-nylon-6 electrospun nanofibers for headspace adsorptive microextraction

    , Article Analytica Chimica Acta ; Volume 713 , 2012 , Pages 63-69 ; 00032670 (ISSN) Bagheri, H ; Aghakhani, A ; Sharif University of Technology
    2012
    Abstract
    A headspace adsorptive microextraction technique was developed using a novel polyaniline-nylon-6 (PANI-N6) nanofiber sheet, fabricated by electrospinning. The homogeneity and the porosity of the prepared PANI-N6 sheet were studied using the scanning electron microscopy (SEM) and nanofibers diameters were found to be around 200nm. The novel nanofiber sheet was examined as an extracting medium to isolate some selected chlorobenzenes (CBs), as model compounds, from aquatic media. The extracted analytes were desorbed using μL-amounts of solvent and eventually an aliquot of extractant was injected into gas chromatography-mass spectrometry (GC-MS). Various parameters affecting the extraction and...