Loading...
Search for: operational-state
0.008 seconds

    Re-evaluation of level 2 PSA results of a VVER-1000 NPP with consideration of innovative severe accident management strategies

    , Article Annals of Nuclear Energy ; Volume 151 , 2021 ; 03064549 (ISSN) Mohsendokht, M ; Jamshidi, M ; Sharif University of Technology
    Elsevier Ltd  2021
    Abstract
    The ultimate purpose of the nuclear power plant safety is to protect the public and the environment from unacceptable radiation exposure in all operational states. This paper presents a novel severe accident management framework to cope with the risk of radioactive material release to the environment. The objective is to reduce the contribution of severe accidents to the large and early release frequencies of radioactive materials for a VVER-1000 nuclear reactor. The proposed approach includes the emergency actions of NPP personnel aiming to recover the lost alternating power and restore the core cooling process by all means available at the site. In addition, mobile equipment including a... 

    Wrist-RoboHab: A robot for treatment and evaluation of brain injury patients

    , Article IEEE International Conference on Rehabilitation Robotics, 27 June 2011 through 1 July 2011, Zurich ; 2011 ; 19457898 (ISSN) ; 9781424498628 (ISBN) Baniasad, M. A ; Farahmand, F ; Ansari, N. N ; Sharif University of Technology
    2011
    Abstract
    This article, introduces a new haptic robot, wrist-RoboHab, for upper limb rehabilitation of post stroke, orthopedic and Parkinson patients., The robot is designed for hand movement therapy and could be used for both treatment and evaluation purposes in three operational states; forearm supination/pronation, wrist flexion/extension and ulnar/radial deviation. At first the mechanical design and control system are described. Then the results of a case study are demonstrated. Clinical results, showed an improvement in Fugle-Meyer, AROM, power and the biomechanical assessment of the spasticity in a chronic patient. Furthermore, it was approved that the robot can have a good interaction with... 

    Decentralized method for load sharing and power management in a PV/battery hybrid source Islanded microgrid

    , Article IEEE Transactions on Power Electronics ; Volume 32, Issue 5 , 2017 , Pages 3525-3535 ; 08858993 (ISSN) Karimi, Y ; Oraee, H ; Golsorkhi, M. S ; Guerrero, J. M ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2017
    Abstract
    This paper proposes a new decentralized power management and load sharing method for a photovoltaic based islanded microgrid consisting of various photovoltaic (PV) units, battery units and hybrid PV/battery units. Unlike the previous methods in the literature, there is no need to communication among the units and the proposed method is not limited to the systems with separate PV and battery units or systems with only one hybrid unit. The proposed method takes into account the available PV power and battery conditions of the units to share the load among them. To cover all possible conditions of the microgrid, the operation of each unit is divided into five states and modified active... 

    Reliability analysis of buck-boost converter considering the effects of operational factors

    , Article 10th International Power Electronics, Drive Systems and Technologies Conference, PEDSTC 2019, 12 February 2019 through 14 February 2019 ; Pages 647-652 , 2019 ; 9781538692547 (ISBN) Tarzamni, H ; Tahami, F ; Fotuhi Firuzabad, M ; Esmaeelnia, F. P ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2019
    Abstract
    In this paper, reliability of conventional pulse width modulation buck-boost converter is analyzed, where the effects of duty cycle, input voltage, output power, voltage gain and time duration are evaluated. These analyses are performed in both continuous and discontinuous conduction modes and Markov process model is utilized to obtain the results. In addition, mean time to failure of this converter is obtained with respect to the aforementioned parameters. In this paper, detailed analyses of reliability in buck-boost converter with different evaluation parameters are presented. Moreover, the plots of MATLAB software are prepared to have complete evaluation in each operating state  

    A new fault tolerant method for cascaded h-bridge inverters based on peak reduction post-fault control method

    , Article 10th International Power Electronics, Drive Systems and Technologies Conference, PEDSTC 2019, 12 February 2019 through 14 February 2019 ; Pages 671-676 , 2019 ; 9781538692547 (ISBN) Babaloo, R ; Fathi, M ; Afjei, E ; Siadatan, A ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2019
    Abstract
    In This paper, a new post-fault control method for symmetric cascaded H-bridge multilevel inverters (CHB-MLIs) is proposed with the aim of the development of CHB-MLIs performance under faulty conditions due to decrease in common mode voltage (CMV). In other words, this technique addresses the exclusive process to select the optimal post-fault state among all available states possess the same amplitude of the output line to line voltages. As a result, this process leads to provide computed phase voltages references to apply to PWM block. Hence, this technique leads to decrease the common mode voltage and eliminate it under some desired output line-line voltages. Finally, the feasibility of... 

    Evaluation of UPFC impacts on power system reliability

    , Article Transmission and Distribution Exposition Conference: 2008 IEEE PES Powering Toward the Future, PIMS 2008, Chicago, IL, 21 April 2008 through 24 April 2008 ; May , 2008 ; 9781424419036 (ISBN) Rajabi Ghahnavieh, A ; Fotuhi Firuzabad, M ; Feuillet, R ; Sharif University of Technology
    2008
    Abstract
    This paper evaluates the reliability impact of UPFC application in power system. The paper proposes a new reliability model for the UPFC which is capable of considering different operating states of UPFC. The model is then applied to a test system to study the reliability impacts of UPFC. The impacts of operating points of different states of the model on the system reliability are analyzed. The role of model parameters in reliability impacts of UPFC is analyzed through the sensitivity analysis. A comparative study is finally conducted to illustrate the applicability of the proposed model compare to that of existing UPFC reliability models. The abilities and deficiencies of the proposed... 

    Seepage through rockfill dams in narrow valleys

    , Article Proceedings of From Research to Practice in Geotechnical Engineering Congress 2008 - From Research to Practice in Geotechnical Engineering, 9 March 2008 through 12 March 2008, New Orleans, LA ; Volume 325 , 2008 , Pages 522-539 ; 9780784409626 (ISBN) Soleimanbeigi, A ; Jafarzadeh, F ; Sharif University of Technology
    2008
    Abstract
    Seepage analysis serves as one of the most significant stages in the design process of an embankment dam. In two-dimensional (2D) seepage analysis of embankment dams, little or no attention is paid to the seepage through side abutments. Moreover the role of grout curtain extensions into the side abutments and abutment material properties are inevitably neglected when performing a 2D seepage analysis. In this paper, two and three-dimensional (3D) models of a rockfill dam during operation state are generated and several unsteady and steady state seepage analyses are performed using finite element method (FEM). The results obtained from 2D and 3D seepage analyses were compared with measurements... 

    Islanding detection for PV and DFIG using decision tree and AdaBoost algorithm

    , Article IEEE PES Innovative Smart Grid Technologies Conference Europe ; 2012 ; 9781467325974 (ISBN) Madani, S. S ; Abbaspour, A ; Beiraghi, M ; Dehkordi, P. Z ; Ranjbar, A. M ; Sharif University of Technology
    2012
    Abstract
    Under smart grid environment, islanding detection plays an important role in reliable operation of distributed generation (DG) units. In this paper an intelligent-based islanding detection algorithm for PV and DFIG units is proposed. Decision tree algorithm is used to classify islanding detection instances. This algorithm is rapid, simple, intelligible and easy to interpret. The error rate of this method is reduced by Adaptive Boosting (AdaBoost) technique. The proposed method is tested on a distribution system including PV, DFIG and synchronous generator. Probable events in the system are simulated under diverse operating states to generate classification data set. First and second order...