Loading...
Search for: ph-measurement
0.007 seconds

    Preparation of a naltrexone HCL potentiometric sensor and its application to pharmaceutical analysis and drug determination in biological fluids

    , Article Journal of Food and Drug Analysis ; Volume 19, Issue 4 , 2011 , Pages 445-451+539 ; 10219498 (ISSN) Ghorbani Bidkorbeh, F ; Shahrokhian, S ; Mohammadi, A ; Dinarvand, R ; Sharif University of Technology
    Abstract
    A novel ion selective electrode is fabricated for naltrexone HCl and used in pharmaceutical analysis and drug determination in biological fluids without complicated pretreatments and extractions, using direct potentiometry. The naltrexone complex with sodium tetraphenyl borate (NaTPB) is obtained by in situ soaking PVC membrane electrode in an 1 × 10 -3 M naltrexone solution. The sensor exhibited fast, reproducible and linear sub-Nernstian response over concentration range of 1 × 10 -5 - 1 × 10 -3 M with a detection limit of 5 × 10 -6 M. The membrane sensor was successfully applied to the determination of naltrexone in capsules as well as for its determination in urine and plasma samples  

    The comparision of Coprinus cinereus peroxidase enzyme and TiO 2 catalyst for phenol removal

    , Article Journal of Environmental Science and Health - Part A Toxic/Hazardous Substances and Environmental Engineering ; Volume 48, Issue 3 , 2013 , Pages 300-307 ; 10934529 (ISSN) Sarkhanpour, R ; Tavakoli, O ; Sarrafzadeh, M. H ; Kariminia, H. R ; Sharif University of Technology
    2013
    Abstract
    This article investigates phenol removal from an aqueous solution by using enzymatic and photocatalytic methods and the efficiency of these methods has been compared. In enzymatic and photocatalytic methods, Coprinus cinereus, peroxidase enzyme and commercial TiO2 powders (Degussa P-25) in aqueous suspension were used, respectively, in ambient temperature. The effects of different operating parameters such as duration of process, catalyst dosage or enzyme concentration, pH of the solution, initial phenol concentration and H2O2 concentration on both processes were examined. In enzymatic method, efficiency of degradation reached 100% within 5min, while in the photocatalytic method, the... 

    Magnetic nanoparticle-based micro-solid phase extraction and GC-MS determination of oxadiargyl in aqueous samples

    , Article Chromatographia ; Volume 74, Issue 5-6 , 2011 , Pages 483-488 ; 00095893 (ISSN) Bagheri, H ; Zandi, O ; Aghakhani, A ; Sharif University of Technology
    Abstract
    A new facile, rapid, inexpensive, and sensitive method based on magnetic micro-solid phase extraction (M-μ-SPE) coupled to gas chromatography-mass spectrometry (GC-MS) was developed for determination of the herbicide oxadiargyl in environmental water samples. The feasibility of employing non-modified magnetic nanoparticles (MNPs) as sorbent was examined and applied to perform the extraction process. Influential parameters affecting the extraction efficiency along with desorption conditions were investigated and optimized. The limit of detection (LOD, S/N = 3) and limit of quantification (LOQ, S/N = 10) of the method under optimized conditions were 0.005 and 0.030 ng mL-1, respectively. The... 

    The effects of Fe(II) and Fe(III) concentration and initial pH on microbial leaching of low-grade sphalerite ore in a column reactor

    , Article Bioresource Technology ; Volume 99, Issue 8 , 2008 , Pages 2840-2845 ; 09608524 (ISSN) Mousavi, S. M ; Yaghmaei, S ; Vossoughi, M ; Roostaazad, R ; Jafari, A ; Ebrahimi, M ; Chabok, O. H ; Turunen, I ; Sharif University of Technology
    2008
    Abstract
    In this study the effects of initial concentration of Fe(II) and Fe(III) ions as well as initial pH on the bioleaching of a low-grade sphalerite ore in a leaching column over a period of 120 days with and without bacteria were investigated. Four different modifications of medium were used as column feed solutions to investigate the effects of initial concentration of Fe(II) and Fe(III) ions on zinc extraction. The experiments were carried out using a bench-scale, column leaching reactor, which was inoculated with mesophilic iron oxidizing bacteria, Acidithiobacillus ferrooxidans, initially isolated from the Sarcheshmeh chalcopyrite concentrate (Kerman, Iran). The effluent solutions were... 

    Optimized bioleaching of copper by indigenous cyanogenic bacteria isolated from the landfill of e-waste

    , Article Journal of Environmental Management ; Volume 261 , 2020 Arab, B ; Hassanpour, F ; Arshadi, M ; Yaghmaei, S ; Hamedi, J ; Sharif University of Technology
    Academic Press  2020
    Abstract
    In this study, indigenous cyanogenic bacterial strains were isolated on nutrient, minimal salt, and soil extract media at various culture conditions from two distinct landfills of e-waste, Iran. Based on their cyanide formation profiles, five most potent isolates were selected for optimization and to this end, the influence of the most effective factors on cyanide production including pH, glycine concentration and temperature were assessed using one-factor at a time method (OFAT). Initial pH of 7, glycine concentration of 2 g/L and temperature of 30°C were obtained as optimal conditions for most of the isolates. Additionally, two bioleaching processes were applied for each bacteria to detect... 

    Fabrication and evaluation of bioresorbable scaffolds for interventional cardiology application with sufficient drug release

    , Article Iranian Journal of Basic Medical Sciences ; Volume 25, Issue 3 , 2022 , Pages 372-382 ; 20083866 (ISSN) Sadeghabadi, A ; Sadrnezhaad, S. K ; Asefnejad, A ; Nemati, N. H ; Sharif University of Technology
    Mashhad University of Medical Sciences  2022
    Abstract
    Objective(s): Bioresorbable scaffolds have been advocated as the new generation in interventional cardiology because they could provide temporary scaffolds and then disappear with resorption. Although, the available stents in clinical trials exhibited biosafety, efficacy, no death, and no apparent thrombosis, Mg-substrate degradation on drug release has not been investigated. Materials and Methods: Therefore, more research has been needed to legitimize the replacement of current stents with Mg-based stents. UV-Vis spectrophotometer, scanning electron microscope (SEM), X-ray diffraction (XRD), pH measurement, H2 evolution, and corrosion tests determined the change in hybrid properties and... 

    Sol-gel-based silver nanoparticles-doped silica - Polydiphenylamine nanocomposite for micro-solid-phase extraction

    , Article Analytica Chimica Acta ; Volume 886 , July , 2015 , Pages 56-65 ; 00032670 (ISSN) Bagheri, H ; Banihashemi, S ; Sharif University of Technology
    Elsevier  2015
    Abstract
    A nanocomposite of silica-polydiphenylamine doped with silver nanoparticles (Ag-SiO2-PDPA) was successfully synthesized by the sol-gel process. For its preparation, PDPA was mixed with butanethiol capped Ag nanoparticles (NPs) and added to the silica sol solution. The Ag NPs were stabilized as a result of their adsorption on the SiO2 spheres. The surface characteristic of nanocomposite was investigated using scanning electron microscopy (SEM). In this work the Ag-SiO2-PDPA nanocomposite was employed as an efficient sorbent for micro-solid-phase extraction (μ-SPE) of some selected pesticides. An amount of 15 mg of the prepared sorbent was used to extract and... 

    Membrane protected conductive polymer as micro-SPE device for the determination of triazine herbicides in aquatic media

    , Article Journal of Separation Science ; Volume 33, Issue 8 , 2010 , Pages 1132-1138 ; 16159306 (ISSN) Bagheri, H ; Khalilian, F ; Naderi, M ; Babanezhad, E ; Sharif University of Technology
    Abstract
    A micro-SPE technique was developed by fabricating a rather small package including a polypropylene membrane shield containing the appropriate sorbent. The package was used for the extraction of some triazine herbicides from aqueous samples. Solvent desorption was subsequently performed in a microvial and an aliquot of extractant was injected into GC-MS. Various sorbents including aniline-ortho-phenylene diamine copolymer, newly synthesized, polypyrrole, multiwall carbon nanotube, C18 and charcoal were examined as extracting media. Among them, conductive polymers exhibited better performance. Influential parameters including extraction and desorption time, desorption solvent and the ionic... 

    Bio-oxidation of ferrous ions by Acidithioobacillus ferrooxidans in amonolithic bioreactor

    , Article Journal of Chemical Technology and Biotechnology ; Volume 84, Issue 4 , 2009 , Pages 504-510 ; 02682575 (ISSN) Kahrizi, E ; Alemzadeh, I ; Vossoughi, M ; Sharif University of Technology
    2009
    Abstract
    Background: The bio-oxidation of ferrous iron is a potential industrial process in the regeneration of ferric iron and the removal of H2S in combustible gases. Bio-oxidation of ferrous iron may be an alternative method of producing ferric sulfate, which is a reagent used for removal of H2S from biogas, tail gas and in the pulp and paper industry. For practical use of this process, this study evaluated the optimal pH and initial ferric concentration. pH control looks like a key factor as it acts both on growth rate and on solubility ofmaterials in the system. Results: Process variables such as pH and amount of initial ferrous ions on oxidation by A. ferrooxidans and the effects of process... 

    Modified solvent microextraction with back extraction combined with liquid chromatography-fluorescence detection for the determination of citalopram in human plasma

    , Article Analytica Chimica Acta ; Volume 610, Issue 2 , 2008 , Pages 211-216 ; 00032670 (ISSN) Bagheri, H ; Khalilian, F ; Babanezhad, E ; Es haghi, A ; Rouini, M. R ; Sharif University of Technology
    2008
    Abstract
    A modified solvent microextraction with back extraction method (SME/BE) combined with high performance liquid chromatography and fluorescence detection (HPLC-FD) was developed for the determination of citalopram in human plasma. Extraction process was performed in a home-made total glass vial without using a teflon ring, usually employed in SME/BE. Citalopram was first extracted from 0.5 mL of plasma, modified with sodium hydroxide, into hexane. Back extraction step was then performed into 5.2 μL of 45 mM ammonium formate solution (pH 4) using a GC microsyringe. The extract was subsequently transferred into a liner-like vial and then injected into the HPLC system. An enrichment factor of 150...