    Blood pressure estimation using photoplethysmogram signal and its morphological features

    , Article IEEE Sensors Journal ; Volume 20, Issue 8 , 2020 , Pages 4300-4310 Hasanzadeh, N ; Ahmadi, M. M ; Mohammadzade, H ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2020
    Abstract
    In this paper, we present a machine learning model to estimate the blood pressure (BP) of a person using only his photoplethysmogram (PPG) signal. We propose algorithms to better detect some critical points of the PPG signal, such as systolic and diastolic peaks, dicrotic notch and inflection point. These algorithms are applicable to different PPG signal morphologies and improve the precision of feature extraction. We show that the logarithm of dicrotic notch reflection index, the ratio of low-to high-frequency components of heart rate (HR) variability signal, and the product of HR multiplied by the modified Normalized Pulse Volume (mNPV) are the key features in accurately estimating the BP... 

    Experimental investigation of the roles of blood volume and density in finger photoplethysmography

    , Article IEEE Sensors Journal ; Volume 13, Issue 5 , 2013 , Pages 1397-1398 ; 1530437X (ISSN) Keikhosravi, A ; Zahedi, E ; Attar, H. M ; Aghajani, H ; Sharif University of Technology
    2013
    Abstract
    Using simultaneous photoplethysmogram (PPG) and pulse transducer signals from the same finger, a high correlation (Mean: 98.6, STD: 1) is obtained between the AC part of the PPG and estimated volume changes (after normalization). These results point to the fact that in the resting fingertip, PPG signal variations are only due to volume changes and that blood density does not change thus has no contribution  

    Electrical analog model of arterial compliance during reactive hyperemia

    , Article 2011 1st Middle East Conference on Biomedical Engineering, MECBME 2011, 21 February 2011 through 24 February 2011, Sharjah ; 2011 , Pages 49-53 ; 9781424470006 (ISBN) Goldoozian, L. S ; Zahedi, E ; Sharif University of Technology
    2011
    Abstract
    Flow mediated dilation (FMD) measurement using ultrasound imaging (FMD-US) has been established as a standard method for assessing the endothelial function. Recently, a less skilled-operator demanding method has been proposed based on the photoplethysmogram (PPG) changes during reactive hyperemia. It was shown that the amplitude of the PPG pulse (FMD-PPG) changed in a quite similar manner to that of the artery diameter in the method of the FMD-US i.e. increases following releasing the cuff and then gradually returns to baseline. In this study PPG changes following reactive hyperaemia were modelled using time-varying passive electrical elements (R, L and C). The output of the electric analog... 

    Discrimination of bilateral finger photoplethysmogram responses to reactive hyperemia in diabetic and healthy subjects using a differential vascular model framework

    , Article Physiological Measurement ; Volume 34, Issue 5 , 2013 , Pages 513-525 ; 09673334 (ISSN) Keikhosravi, A ; Aghajani, H ; Zahedi, E ; Sharif University of Technology
    2013
    Abstract
    Endothelial dysfunction assessment has received considerable attention due to its potential in early screening of cardiovascular diseases. Since the seminal work by Celermajer in flow-mediated dilation (FMD) based on B-mode ultrasound measurement of the brachial artery dilation following limb ischemia, many attempts have been made toward applying this method to clinical, non-invasive endothelial dysfunction assessment. One major obstacle toward achieving this objective has been the relative high cost of the required setup and skilled manpower. Such limitations have prompted the investigation of other non-invasively accessible signals such as the photoplethysmogram (PPG) in relation to FMD.... 

    Effect of deep breath on the correlation between the wrist and finger photoplethysmograms

    , Article 2012 19th Iranian Conference of Biomedical Engineering, ICBME 2012 ; 2012 , Pages 135-138 ; 9781467331302 (ISBN) Keikhosravi, A ; Zahedi, E ; Sharif University of Technology
    2012
    Abstract
    In this paper, a special probe is designed using an array of photodiodes and a 960 nm LED for recording the wrist photoplethysmogram (PPG). The design is based on Monte-Carlo simulation of light propagation in tissues. Two series of experiments were carried-out: normal breathing and deep breathing. In both experiments, finger and wrist PPG were simultaneously recorded from the index finger. In the first series of experiment, signals from 9 subjects were recorded and the correlation coefficient for the raw signals (AC+DC), the AC and DC components of wrist and finger PPG were (62.5% ± 12.1%), (91.2% ± 6.9%) and (61% ± 13.4%) respectively. In the second series of experiment (deep breathing),... 

    Effect of dyslipidemia on a simple morphological feature extracted from photoplethysmography flow mediated dilation

    , Article International Conference in Electronic Engineering and Computing Technology, London, 1 July 2009 through 3 July 2009 ; Volume 60 LNEE , 2010 , Pages 551-561 ; 18761100 (ISSN) ; 9789048187751 (ISBN) Zaheditochai, M ; Zahedi, E ; Mohd Ali, M. A ; Sharif University of Technology
    2010
    Abstract
    Dyslipidemia is considered to be one of the main heart risk factors, affecting the endothelial vascular function, which can be non-invasively investigated by ultrasound flow-mediated dilation (US-FMD). However, US-FMD comes at a high-cost and is operator-dependent. In this paper, the effect of dyslipidemia on the photoplethysmogram (PPG) signal recorded from collateral index fingers is investigated following a previous study where it was shown that results similar to that of US-FMD can be replicated by the PPG. Two groups, consisting of 30 healthy subjects free from any risk factors and 30 subjects who have only dyslipidemia as risk factor were respectively considered. The percent change in... 

    EEG/PPG effective connectivity fusion for analyzing deception in interview

    , Article Signal, Image and Video Processing ; Volume 14, Issue 5 , 2020 , Pages 907-914 Daneshi Kohan, M ; Motie Nasrabadi, A ; Shamsollahi, M. B ; Sharifi, A ; Sharif University of Technology
    Springer  2020
    Abstract
    In this research, the interaction between electroencephalogram (EEG) and, a cardiac parameter, photoplethysmogram (PPG), using connectivity measures to emphasize the importance of autonomic nervous system over the central nervous system during a deception is investigated. In this survey, connectivity analysis was applied, since it can provide information flow of brain regions; moreover, lying and truth appear to be cohered with the flow of information in the brain. Initially, a new wavelet-based approach for EEG/PPG effective connectivity fusion was introduced; then, it was validated for 41 subjects. For each subject, after extracting specific wavelet component of EEG and PPG signals, an... 

    Applicability of adaptive noise cancellation to fetal heart rate detection using photoplethysmography

    , Article Computers in Biology and Medicine ; Volume 38, Issue 1 , 2008 , Pages 31-41 ; 00104825 (ISSN) Zahedi, E ; Beng, G. K ; Sharif University of Technology
    2008
    Abstract
    In this paper, an approach based on adaptive noise cancellation (ANC) is evaluated for extraction of the fetal heart rate using photoplethysmographic signals from the maternal abdomen. A simple optical model is proposed in which the maternal and fetal blood pulsations result in emulated signals where the lower SNR limit (fetal to maternal) is - 25 dB. It is shown that a recursive least-squares algorithm is capable of extracting the peaks of the fetal PPG from these signals, for typical values of maternal and fetal tissues. © 2007 Elsevier Ltd. All rights reserved  

    Discrimination between different degrees of coronary artery disease using time-domain features of the finger photoplethysmogram in response to reactive hyperemia

    , Article Biomedical Signal Processing and Control ; Volume 18 , 2015 , Pages 282-292 ; 17468094 (ISSN) Hosseini, Z. S ; Zahedi, E ; Movahedian Attar, H ; Fakhrzadeh, H ; Parsafar, M. H ; Sharif University of Technology
    Elsevier Ltd  2015
    Abstract
    Atherosclerosis is a major cause of coronary artery disease leading to morbidity and mortality worldwide. Currently, coronary angiography is considered to be the most accurate technique to diagnose coronary artery disease (CAD). However, this technique is an invasive and expensive procedure with risks of serious complications. Since the symptoms of CAD are not noticed until advanced stages of the disease, early and effective diagnosis of CAD is considered a pertinent measure. In this paper, a non-invasive optical signal, the finger photoplethysmogram (PPG) obtained before and after reactive hyperemia is investigated to discriminate between subjects with different CAD conditions. To this end,... 

    Experimental feasibility study of estimation of the normalized central blood pressure waveform from radial photoplethysmogram

    , Article Journal of Healthcare Engineering ; Volume 6, Issue 1 , 2015 , Pages 121-144 ; 20402295 (ISSN) Zahedi, E ; Sohani, V ; Mohd. Ali, M. A ; Chellappan, K ; Beng, G. K ; Sharif University of Technology
    Multi-Science Publishing Co. Ltd  2015
    Abstract
    The feasibility of a novel system to reliably estimate the normalized central blood pressure (CBPN) from the radial photoplethysmogram (PPG) is investigated. Right-wrist radial blood pressure and left-wrist PPG were simultaneously recorded in five different days. An industry-standard applanation tonometer was employed for recording radial blood pressure. The CBP waveform was amplitude-normalized to determine CBPN. A total of fifteen second-order autoregressive models with exogenous input were investigated using system identification techniques. Among these 15 models, the model producing the lowest coefficient of variation (CV) of the fitness during the five days was...