Loading...
Search for: pounding-force
0.004 seconds

    Pipe dampers as passive devices for seismic control of isolated bridges

    , Article Structural Control and Health Monitoring ; Volume 24, Issue 2 , 2017 ; 15452255 (ISSN) Mahjoubi, S ; Maleki, S ; Sharif University of Technology
    John Wiley and Sons Ltd  2017
    Abstract
    During an earthquake, pounding of bridge superstructure into abutments is potentially destructive to structural elements and may cause unseating failure and collapse. By using energy dissipative devices such as passive dampers, the harmful pounding force may be prevented. One of the most economical passive dampers for structural applications is the pipe damper, recently introduced by the authors. In this paper, computer models of a two-span 60-m long conventional overpass bridge are equipped with different lengths of two types of pipe dampers, namely the dual-pipe (DPD) and infilled-pipe (IPD) dampers. A simplified lumped-mass model for the bridge considering soil stiffness is proposed and...