Loading...
Search for: protective-action
0.011 seconds

    Frozen leg operation of a three-phase dual active bridge DC/DC converter at light loads

    , Article Conference Proceedings - IEEE Applied Power Electronics Conference and Exposition - APEC ; Volume 2018-March , 18 April , 2018 , Pages 3385-3391 ; 9781538611807 (ISBN) Haghbin, S ; Blaabjerg, F ; Yazdani, F ; Bahman, A. S ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2018
    Abstract
    A three-phase dual active bridge (DAB) converter is designed and constructed as the DC/DC stage of a 50 kW fast charger station. Recently introduced 300A SiC power modules and drivers are utilized in the converter to obtain a high efficiency. Each module has two interconnected switches with anti-parallel diodes resembling a converter leg. It is observed that the driver halts the module operation as a result of protective actions such as over-current, gate under-voltage, or gate overvoltage. In such case the module operates as a leg with two diodes until an external hardware signal resets the driver. The aim of this paper is to provide analysis, simulation and experiments for a three-phase...