    Short-circuit analysis in three-phase quasi-Z-source inverter

    , Article 17th IEEE International Conference on Environment and Electrical Engineering and 2017 1st IEEE Industrial and Commercial Power Systems Europe, EEEIC / I and CPS Europe 2017, 6 June 2017 through 9 June 2017 ; 2017 ; 9781538639160 (ISBN) Yaghoubi, M ; Moghani, J. S ; Noroozi, N ; Zolghadri, M. R ; IEEE EMC Society; IEEE Industry Applications Society (IAS); IEEE Power and Energy Society (PES) ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2017
    Abstract
    In this paper, the short-circuit fault in three-phase quasi-Z-source inverter (q-ZSI) is analyzed and a linear model is proposed for the short-circuit analysis. The proposed model is based on the state space equations of the system. By using this model, the most critical situation during short-circuit fault is recognized; the maximum reaction time for the protection system could be estimated and elements that are prone to failure are identified as well. The analysis is categorized into two groups, leg fault and switch fault. The linear model is confirmed by simulation of 1kw three-phase q-ZSI. © 2017 IEEE  

    Comparison of common-mode voltage in three-phase quasi-Z-source inverters using different shoot-through implementation methods

    , Article Proceedings - 2018 IEEE 12th International Conference on Compatibility, Power Electronics and Power Engineering, CPE-POWERENG 2018 ; 4 June , 2018 , Pages 1-6 ; 9781538625088 (ISBN) Noroozi, N ; Zolghadri, M. R ; Yaghoubi, M ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2018
    Abstract
    In Z-source family inverters, shoot-through (ST) states are applied as a part of passive state in each switching cycle. The distribution of ST intervals along a switching period affects the system parameters as total harmonic distortion (THD), switching loss and common-mode voltage (CMV). In this paper, ST methods in a three-phase quasi-Z-source inverter (q-ZSI) are compared due to the CMV level. High-frequency harmonics of CMV cause leakage current flow in a transformerless grid-connected photovoltaic (PV) system. Through the comparison of the ST methods, the method with minimum CMV is identified. The experimental results are Prasented for a low voltage q-ZSI prototype. © 2018 IEEE  

    Performance Improvement of Grid-connected Quasi-Z-Source Photovoltaic Inverter to Reduce Leakage Currents

    , Ph.D. Dissertation Sharif University of Technology Noroozi, Negar (Author) ; Zolghadri, Mohammad Reza (Supervisor)
    Abstract
    A quasi-Z-source inverter is a beneficial structure in photovoltaic applications. In a transformerless grid-connected inverter system, the common-mode voltage fluctuations cause the leakage current flow through the ground. The low-frequency harmonics of the common-mode voltage results in the malfunction of the residual current device. On the other hand, the high-frequency harmonics of the common-mode voltage cause EMI problems, additional loss and disturbance in the output currents. In this thesis, some methods are presented to reduce the leakage current in a three-phase quasi-Z-source inverter. First, different shoot-through implementation methods are investigated. By modifying the number... 

    Improvement of Z-source and Quasi-z Source Inverter for Photovoltaic Applications

    , M.Sc. Thesis Sharif University of Technology Aseyedali, Mahdi (Author) ; Parniani, Mostafa (Supervisor)
    Abstract
    The Z-source and quasi-Z source inverter have a capability to increase and decrease the output voltage without using extra switching stages or transformer. Therefor these inverters are an excellent choice for applications such as photovoltaic sources because of their higher efficiency, higher reliability and lower volume and cost. One drawback of these inverters is the leakage current that causes undesirable effect on the power system and safety issues. In this research we are going to develop a new modulation method for these inverters to reject the leakage current. In this method the harmonic content of common mode voltage is concentrated on the switching frequency and its harmonics while... 

    Three-phase quasi-Z-source inverter with constant common-mode voltage for photovoltaic application

    , Article IEEE Transactions on Industrial Electronics ; 2017 ; 02780046 (ISSN) Noroozi, N ; Zolghadri, M. R ; Sharif University of Technology
    Abstract
    In trasformerless grid-connected photovoltaic (PV) systems, common-mode voltage (CMV) fluctuations cause leakage current flow through the stray capacitance of the PV panels. Shoot-through (SH) states in a quasi-Z-source inverter (q-ZSI), increase the amplitude of high order harmonics of CMV. In this paper, by using the modulation technique based on odd PWM (OPWM) and minor change in the Z network of the three-phase q-ZSI, the leakage current is blocked. No extra semiconductor element is added. By the proposed technique, CMV is kept nearly constant during switching cycles. The experimental results for CMV analysis in a 1kW prototype are presented to verify the theoretical analysis. IEEE  

    A modulation method for leakage current reduction in a three-phase grid-tie quasi-Z-source inverter

    , Article IEEE Transactions on Power Electronics ; 2018 ; 08858993 (ISSN) Noroozi, N ; Yaghoubi, M ; Zolghadri, M ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2018
    Abstract
    The leakage current originated from the fluctuations of the common-mode voltage (CMV) is an issue in a transformerless grid-connected photovoltaic (PV) system. In this paper, a modified space vector modulation based on the Fourier transform analysis is proposed to reduce the leakage current in a three-phase quasi-Z-source inverter (qZSI). The CMV harmonic content in a qZSI contains low and high-frequency harmonics which cause safety and EMI problems respectively. By implementing the proposed modulation in a three-phase qZSI, the low-frequency harmonics of the CMV are mainly reduced. The distribution of the high-frequency harmonics is also modified in a way they can be simply filtered.... 

    IGBT open-circuit fault diagnosis in a Quasi-Z-source inverter

    , Article IEEE Transactions on Industrial Electronics ; Volume 66, Issue 4 , 2019 , Pages 2847-2856 ; 02780046 (ISSN) Yaghoubi, M ; Shokrollahi Moghani, J ; Noroozi, N ; Zolghadri, M. R ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2018
    Abstract
    In this paper, a fast and practical method is proposed for open-circuit (OC) fault diagnosis (FD) in a three-phase quasi-Z-source inverter (q-ZSI). Compared to the existing fast OC FD techniques in three-phase voltage-source inverters (VSIs), this method is more cost-effective since no ultra-fast processor or high-speed measurement is required. Additionally, the method is independent of the load condition. The proposed method is only applicable to Z-source family inverters and is based on observing the effect of shoot-through (SH) intervals on the system variables during switching periods. The proposed algorithm includes two consecutive stages: OC detection and fault location identification.... 

    Three-Phase quasi-Z-source inverter with constant common-mode voltage for photovoltaic application

    , Article IEEE Transactions on Industrial Electronics ; Volume 65, Issue 6 , 2018 , Pages 4790-4798 ; 02780046 (ISSN) Noroozi, N ; Zolghadri, M. R ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2018
    Abstract
    In trasformerless grid-connected photovoltaic (PV) systems, common-mode voltage (CMV) fluctuations cause leakage current flow through the stray capacitance of the PV panels. Shoot-through states in a quasi-Z-source inverter (q-ZSI) increase the amplitude of high-order harmonics of CMV. In this paper, by using the modulation technique based on odd pulse width modulation and minor change in the Z network of the three-phase q-ZSI, the leakage current is blocked. No extra semiconductor element is added. By the proposed technique, CMV is kept nearly constant during switching cycles. The experimental results for CMV analysis in a 1kW prototype are presented to verify the theoretical analysis. ©... 

    A modulation method for leakage current reduction in a three-phase grid-tie quasi-z-source inverter

    , Article IEEE Transactions on Power Electronics ; Volume 34, Issue 6 , 2019 , Pages 5439-5450 ; 08858993 (ISSN) Noroozi, N ; Yaghoubi, M ; Zolghadri, M. R ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2019
    Abstract
    The leakage current originated from the fluctuations of the common-mode voltage (CMV) is an issue in a transformerless grid-connected photovoltaic system. In this paper, a modified space vector modulation based on the Fourier transform analysis is proposed to reduce the leakage current in a three-phase quasi-Z-source inverter (qZSI). The CMV harmonic content in a qZSI contains low-and high-frequency harmonics that cause safety and electromagnetic interference problems, respectively. By implementing the proposed modulation in a three-phase qZSI, the low-frequency harmonics of the CMV are mainly reduced. The distribution of the high-frequency harmonics is also modified in a way they can be... 

    IGBT Open-circuit fault diagnosis in a quasi-z-source inverter

    , Article IEEE Transactions on Industrial Electronics ; Volume 66, Issue 4 , 2019 , Pages 2847-2856 ; 02780046 (ISSN) Yaghoubi, M ; Moghani, J. S ; Noroozi, N ; Zolghadri, M. R ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2019
    Abstract
    In this paper, a fast and practical method is proposed for open-circuit (OC) fault diagnosis (FD) in a three-phase quasi-Z-source inverter (q-ZSI). Compared with the existing fast OC FD techniques in three-phase voltage source inverters, this method is more cost-effective since no ultrafast processor or high-speed measurement is required. Additionally, the method is independent of the load condition. The proposed method is only applicable to Z-source family inverters and is based on observing the effect of shoot-through intervals on the system variables during switching periods. The proposed algorithm includes two consecutive stages: OC detection and fault location identification. When both... 

    Harmonic analysis of common-mode voltage in quasi-z-source inverters

    , Article 2019 IEEE International Conference on Industrial Technology, ICIT 2019, 13 February 2019 through 15 February 2019 ; Volume 2019-February , 2019 , Pages 1778-1783 ; 9781538663769 (ISBN) Noroozi, N ; Yaghoubi, M ; Davoodi, A ; Ouni, S ; Zolghadri, M ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2019
    Abstract
    In a transformerless grid-connected photovoltaic system, many issues arise from the leakage current flow into the ground, as EMI problems. The leakage current is originated from the common-mode voltage fluctuations. In this paper, the common-mode voltage harmonics in a three-phase quasi-Z-source inverter are analyzed using Fourier transform and a closed-loop formulation is presented for the harmonics value. The shoot-through mode in a quasi-Z-source inverter causes extra fluctuations in the common-mode voltage comparing to a classic inverter. The proposed harmonic analysis method provides a systematic way to figure out how shoot-through mode and also other parameters affect the common-mode...