Loading...
Search for: radiography
0.008 seconds
Total 33 records

    An investigation on the improvement of neutron radiography system of the tehran research reactor by using MCNPX simulations

    , Article Nuclear Engineering and Technology ; Volume 53, Issue 10 , 2021 , Pages 3413-3420 ; 17385733 (ISSN) Amini, M ; Zamzamian, M ; Fadaei, A. H ; Gharib, M ; Feghhi, A. H ; Sharif University of Technology
    Korean Nuclear Society  2021
    Abstract
    Applying the available neutron flux for medical and industrial purposes is the most important application of research reactors. The neutron radiography system is used for non-destructive testing (NDT) of materials so that it is one of the main applications of nuclear research reactors. One of these research reactors is the 5 MW pool-type light water research reactor of Tehran (TRR). This work aims to investigate on materials and location of the beam tube (BT) of the TRR radiography system to improve the index parameters of BT. Our results showed that a through-type BT with 20 cm thick carbon neutron filter, 1.2 cm and 9.4 cm of the diameter of inlet (D1) and output (D2) BT, respectively... 

    Segmentation of teeth in CT volumetric dataset by panoramic projection and variational level set

    , Article International Journal of Computer Assisted Radiology and Surgery ; Volume 3, Issue 3-4 , 2008 , Pages 257-265 ; 18616410 (ISSN) Hosntalab, M ; Aghaeizadeh Zoroofi, R ; Abbaspour Tehrani Fard, A ; Shirani, G ; Sharif University of Technology
    Springer Verlag  2008
    Abstract
    Purpose: Quantification of teeth is of clinical importance for various computer assisted procedures such as dental implant, orthodontic planning, face, jaw and cosmetic surgeries. In this regard, segmentation is a major step. Methods: In this paper, we propose a method for segmentation of teeth in volumetric computed tomography (CT) data using panoramic re-sampling of the dataset in the coronal view and variational level set. The proposed method consists of five steps as follows: first, we extract a mask in a CT images using Otsu thresholding. Second, the teeth are segmented from other bony tissues by utilizing anatomical knowledge of teeth in the jaws. Third, the proposed method is followed... 

    Evaluation and Diagnosis of Intraosseos Lesions in Panoramic Radiographs

    , M.Sc. Thesis Sharif University of Technology Abdi, Amir Hossein (Author) ; Kasaie, Shohre (Supervisor)
    Abstract
    Panoramic radiography is known to be one of the preliminary means in diagnoses of maxillofacial intraosseos lesions, which has a big role in increasing the prognosis of such patients. Considering the fact that nowadays most health-care centers are equipped with digital radiography systems, we can rely on image processing techniques to recognize such lesions automatically.In this study, we try to segment mandible (lower jaw) out of panoramic image by means of some innovative algorithms based on edge detection and edge following, and some atlas-based methods. Then by extracting some features such as intensity, homogeneity, local energy and local gradient and with the help of SVM classifier we... 

    In-service corrosion evaluation in pipelines using gamma radiography - A numerical approach

    , Article Insight: Non-Destructive Testing and Condition Monitoring ; Volume 46, Issue 7 , 2004 , Pages 396-398 ; 13542575 (ISSN) Edalati, K ; Rastkhah, N ; Kermani, A ; Seidi, M ; Movafeghi, A ; Sharif University of Technology
    2004
    Abstract
    Wall thickness measurement and deterioration determination of 6 and 10 inch pipes due to corrosion/erosion/pitting was evaluated by using radiographic film density measurements. Special reference blocks were prepared with defined step wall reductions and artificial defects. Gamma radiography with a Ir-192 source was used. A double-wall technique with longitudinal film arrangement was used for this purpose. Formulae were developed from the experiments for numerical calculations. It was observed that this method can determine remaining wall thickness as well as pitting corrosion in insulated and non-insulated pipes with differential and absolute density measurements. The purpose of the work... 

    Sagittal range of motion of the thoracic spine using standing digital radiography: A throughout comparison with non-radiographic data reviewed from the literature

    , Article Scientia Iranica ; Volume 26, Issue 3B , 2019 , Pages 1307-1315 ; 10263098 (ISSN) Madinei, S ; Arjmand, N ; Sharif University of Technology
    Sharif University of Technology  2019
    Abstract
    Previous studies have measured thoracic Range of Motion (RoM) using either skin-mounted devices or supine CT-imaging and have reported on quite different RoMs. Given the inherent shortcomings of measurements of vertebrae movements from the overlying skin, the present study aims to measure normal RoM of the thoracic spine in the sagittal plane using the upright digital radiography. Lateral radiographs of the thoracic spine were obtained from eight asymptomatic male subjects in upright standing and full forward flexion using a mobile U-arm digital radiographic system. Total (T1-T12), upper (T1-T6), and lower (T6-T12) thoracic RoMs were measured. A throughout comparison of available skin-based... 

    Sagittal range of motion of the thoracic spine using standing digital radiography: A throughout comparison with non-radiographic data reviewed from the literature

    , Article Scientia Iranica ; Volume 26, Issue 3B , 2019 , Pages 1307-1315 ; 10263098 (ISSN) Madinei, S. S ; Arjmand, N ; Sharif University of Technology
    Sharif University of Technology  2019
    Abstract
    Previous studies have measured thoracic Range of Motion (RoM) using either skin-mounted devices or supine CT-imaging and have reported on quite different RoMs. Given the inherent shortcomings of measurements of vertebrae movements from the overlying skin, the present study aims to measure normal RoM of the thoracic spine in the sagittal plane using the upright digital radiography. Lateral radiographs of the thoracic spine were obtained from eight asymptomatic male subjects in upright standing and full forward flexion using a mobile U-arm digital radiographic system. Total (T1-T12), upper (T1-T6), and lower (T6-T12) thoracic RoMs were measured. A throughout comparison of available skin-based... 

    Investigation of the Photonic Scattering Error in Radiography of Pipes and its Evaluation by Mote- carlo Simulation

    , M.Sc. Thesis Sharif University of Technology Masoumi Kolvanaq, Hojjat (Author) ; Vossoughi, Nasser (Supervisor) ; Movafeghi, Amir (Co-Advisor) ; Kermani, Abotaleb (Co-Advisor)
    Abstract
    Non-destructive testing method is for detect specimen flaws such as (crack, porosity, impure, welding defects, corrosion etc.) without destruction the specimen under inspection. Particular characteristic of radiography is an image product from specimen inside under testing where help to identity and better comprehend at flaw nature. Photon scattering is one of important factor to reduce image quality and signal to noise ratio. Scattered photons can due toexistent ingredient in the radiography environment and curvature of material transmission pipe where cause the disorder creation in the radiography images. In this research, pipe radiography simulated using the TIC and TIR radiography... 

    Comments regarding: Pereira SA, Lopez M, Lavado N, Abreu JM, Silva H. A clinical risk prediction model of orthodontic-induced external apical root resorption. Revista Portuguesa de Estomatologia, Medicina Dentária e Cirurgia Maxilofacial 2014;55(2):66-72

    , Article Revista Portuguesa de Estomatologia, Medicina Dentaria e Cirurgia Maxilofacial ; Volume 56, Issue 3 , 2015 , Pages 141-142 ; 16462890 (ISSN) Abdi, A. H ; Sharif University of Technology
    Elsevier Doyma  2015

    Quality improvement of digitized radiographs by filtering technique development based on morphological transformations

    , Article 2004 Nuclear Science Symposium, Medical Imaging Conference, Symposium on Nuclear Power Systems and the 14th International Workshop on Room Temperature Semiconductor X- and Gamma- Ray Detectors, Rome, 16 October 2004 through 22 October 2004 ; Volume 3 , 2004 , Pages 1845-1849 ; 10957863 (ISSN) Movafeghi, A ; Taheri, M ; Kargarnovin, M. H ; Ghasemi, F ; Rokrok, B ; Seiedi, M ; Edaalati, K ; Kermani, A ; Rastkhah, N ; Sharif University of Technology
    2004
    Abstract
    Radiographic inspection is the most appreciated technique among the other non-destructive testing methods due to producing unique finger print record as the film. Converting of radiographs to a digital format and further digital image processing is the best method of enhancing the image quality and assisting the interpreter on his evaluation. In this research, different algorithms were used for image enhancement and radiograph interpretation in MATLAB environment. A graphical user interface (GUI) was created for implementation of different algorithms. Both spatial and frequency (wavelet) domains techniques were used for image enhancement. Results showed that the defect recognition... 

    Design of Neutron Radiography System Based on the Time of Flight Method Using GEANT4 Software

    , M.Sc. Thesis Sharif University of Technology Vahidian, Mohamad (Author) ; Hosseini, Abolfazl (Supervisor) ; Mehrabi, Mohammad (Co-Supervisor)
    Abstract
    Neutron Radiography is one of the non-destructive testing methods of materials and due to its special application compared to gamma or X-ray imaging, it is highly regarded and developed in the world. A special application of neutron imaging is the imaging of materials with a low atomic number, even when coated with a material with a high atomic number. Neutron Radiography has different methods for capturing and recording images by neutrons. Among these methods, the following 7 methods can be mentioned: Neutron radiography (film), Track Etch, Digital neutron imaging, Neutron camera (DR System), Image plates (CR System), Flat panel silicon detectors (DR system) and Micro channel plates (DR... 

    A hybrid fuzzy based algorithm for 3D human airway segmentation

    , Article 2nd International Conference on Bioinformatics and Biomedical Engineering, iCBBE 2008, Shanghai, 16 May 2008 through 18 May 2008 ; 2008 , Pages 2295-2298 ; 9781424417483 (ISBN) Yousefi Rizi, F ; Ahmadian, A ; Sahba, N ; Tavakoli, V ; Alirezaie, J ; Fatemizadeh, E ; Rezaie, N ; Sharif University of Technology
    IEEE Computer Society  2008
    Abstract
    Segmentation of the human airway tree from volumetric computed tomography images is an important stage for many clinical applications such as virtual bronchoscopy. The main challenges of previously developed methods are to deal with two problems namely, leaking into the surrounding lung parenchyma during segmentation and the need to manually adjust the parameters. To overcome these problems, a multi-seeded fuzzy based region growing approach in conjuction with the spatial information of voxels is proposed. Comparison with a commonly used region growing segmentation algorithm shows that the proposed method retrieves more accurate results by achieving the specificity and sensitivity of 98.81%... 

    Flaw detection improvement of digitised radiographs by morphological transformations

    , Article Insight: Non-Destructive Testing and Condition Monitoring ; Volume 47, Issue 10 , 2005 , Pages 625-630 ; 13542575 (ISSN) Movafeghi, A ; Kargarnovin, M. H ; Soltanian Zadeh, H ; Taheri, M ; Ghasemi, F ; Rokrok, B ; Edalati, K ; Rastkhah, N ; Sharif University of Technology
    2005
    Abstract
    Radiographic inspection is one of the most appreciated techniques among non-destructive testing methods due to the production of a film which acts as a unique fingerprint record. Converting radiographs to a digital format and further digital image processing is the best method of enhancing the image quality and assisting the interpreter on his evaluation. In this research, different algorithms were used for image enhancement and radiograph interpretation in MATLAB environment. A graphical user interface (GUI) was created for implementation of different algorithms. Both spatial and frequency domains techniques were used for image enhancement. The main enhancement technique was a spatial... 

    Determination of Optimum Material and Thickness of Filter Based on Radiation Energy in Digital Industrial Radiography (CR) Using MCNP Monte Carlo Simulation Code

    , M.Sc. Thesis Sharif University of Technology Haghizadeh, Cyrus (Author) ; Vosoughi, Naser (Supervisor) ; Rokrok, Behrouz (Supervisor) ; Movafeghi, Amir (Co-Supervisor)
    Abstract
    In this study, the effect of external filter on the various parameters of image quality in digital industrial radiography by CR method for steel and aluminum piece has been investigated. The filter reduces the noise of scattered beams by absorbing the low-energy beams in the X-ray spectrum that are most likely to be scattered, but high filter thicknesses can attenuate the more energetic beams and have a negatively effect on the image quality. On the other hand, the absorption of those low-energy beams increases the average spectrum energy and thus reduce the contrast, so it is necessary to use the appropriate material and thickness of the filter. For this purpose, to examine the filter... 

    Generation of database schemas from Z specifications

    , Article IEEE International Conference on Electro Information Technology, 15 May 2011 through 17 May 2011, Mankato, MN ; 2011 ; 21540357 (ISSN) Khalafinejad, S ; Mirian Hosseinabadi, S. H ; IEEE Region 4 (R4) ; Sharif University of Technology
    2011
    Abstract
    Automatic translation of a high-level specification language to an executable implementation would be highly useful in maximizing the benefits of formal methods. We will introduce a set of translation functions to fill the specification-implementation gap in the domain of database applications. Because the mathematical foundation of Z has many properties in common with SQL, a direct mapping from Z to SQL structures can be found. We derive a set of translation functions from Z to SQL for the generation of a database. The proposed methodology results in reducing the expenses and duration of the software development, and also, prevents the errors originated from the manual translation of... 

    Statistical construction of a Japanese male liver phantom for internal radionuclide dosimetry

    , Article Radiation Protection Dosimetry ; Volume 141, Issue 2 , 2010 , Pages 140-148 ; 01448420 (ISSN) Babapour Mofrad, F ; Aghaeizadeh Zoroofi, R ; Abbaspour Tehrani Fard, A ; Akhlaghpoor, S ; Hori, M ; Chen, Y. W ; Sato, Y ; Sharif University of Technology
    2010
    Abstract
    A computational framework is presented, based on statistical shape modelling, for construction of race-specific organ models for internal radionuclide dosimetry and other nuclear-medicine applications. This approach was applied to the construction of a Japanese liver phantom, using the liver of the digital Zubal phantom as the template and 35 liver computed tomography (CT) scans of male Japanese individuals as a training set. The first step was the automated object-space registration (to align all the liver surfaces in one orientation), using a coherent-point-drift maximum-likelihood alignment algorithm, of each CT scan-derived manually contoured liver surface and the template Zubal liver... 

    Joint source-channel coding using finite state integer arithmetic codes

    , Article Proceedings of 2009 IEEE International Conference on Electro/Information Technology, EIT 2009, 7 June 2009 through 9 June 2009, Windsor, ON ; 2009 , Pages 19-22 ; 9781424433551 (ISBN) Moradmand, H ; Payandeh, A ; Aref, M. R ; Sharif University of Technology
    2009
    Abstract
    Inserting redundancy to arithmetic codes is a common strategy to add error detection capability to this well-known family of source codes. By using this strategy error correction is possible through some decoding algorithms such as Viterbi decoder. In this paper a system has proposed that uses finite state integer arithmetic codes (FSAC) as a joint source-channel code in combination with a cyclic redundancy check (CRC) and a List Viterbi decoder. The proposed scheme has shown better performance than previous ones. © 2009 IEEE  

    A modified deep convolutional neural network for detecting COVID-19 and pneumonia from chest X-ray images based on the concatenation of Xception and ResNet50V2

    , Article Informatics in Medicine Unlocked ; Volume 19 , 2020 Rahimzadeh, M ; Attar, A ; Sharif University of Technology
    Elsevier Ltd  2020
    Abstract
    In this paper, we have trained several deep convolutional networks with introduced training techniques for classifying X-ray images into three classes: normal, pneumonia, and COVID-19, based on two open-source datasets. Our data contains 180 X-ray images that belong to persons infected with COVID-19, and we attempted to apply methods to achieve the best possible results. In this research, we introduce some training techniques that help the network learn better when we have an unbalanced dataset (fewer cases of COVID-19 along with more cases from other classes). We also propose a neural network that is a concatenation of the Xception and ResNet50V2 networks. This network achieved the best... 

    Error propagation in non-iterative EIT block method

    , Article ISSPIT 2007 - 2007 IEEE International Symposium on Signal Processing and Information Technology, Cairo, 15 December 2007 through 18 December 2007 ; 2007 , Pages 678-681 ; 9781424418350 (ISBN) Abbasi, A ; Pashakhanlou, F ; Vosoughi Vahdat, B ; Sharif University of Technology
    2007
    Abstract
    The Block method approach to solve EIT problem leads to an exact solution if the measurements are done without error. Non-iterative method is a feasible approach on solving 3D EIT forward problem. However, the effect of the measurement error has not been considered in this method yet. In this article, the 3D model of EIT with block method has been considered. The required equations to solve the forward problem are then generated. To solve the forward problem, non-iterative method has been employed. Effect of the measurement error on forward problem for a 3D model of EIT are generated. It has been shown that for a sample 3D model, measurement error can propagate exponentially. ©2007 IEEE  

    COVID-19 diagnosis using capsule network and fuzzy c -means and mayfly optimization algorithm

    , Article BioMed Research International ; Volume 2021 , 2021 ; 23146133 (ISSN) Farki, A ; Salekshahrezaee, Z ; Mohammadi Tofigh, A ; Ghanavati, R ; Arandian, B ; Chapnevis, A ; Sharif University of Technology
    Hindawi Limited  2021
    Abstract
    The COVID-19 epidemic is spreading day by day. Early diagnosis of this disease is essential to provide effective preventive and therapeutic measures. This process can be used by a computer-aided methodology to improve accuracy. In this study, a new and optimal method has been utilized for the diagnosis of COVID-19. Here, a method based on fuzzy C-ordered means (FCOM) along with an improved version of the enhanced capsule network (ECN) has been proposed for this purpose. The proposed ECN method is improved based on mayfly optimization (MFO) algorithm. The suggested technique is then implemented on the chest X-ray COVID-19 images from publicly available datasets. Simulation results are... 

    Subject-specific loads on the lumbar spine in detailed finite element models scaled geometrically and kinematic-driven by radiography images

    , Article International Journal for Numerical Methods in Biomedical Engineering ; Volume 35, Issue 4 , 2019 ; 20407939 (ISSN) Dehghan Hamani, I ; Arjmand, N ; Shirazi Adl, A ; Sharif University of Technology
    Wiley-Blackwell  2019
    Abstract
    Traditional load-control musculoskeletal and finite element (FE) models of the spine fail to accurately predict in vivo intervertebral joint loads due mainly to the simplifications and assumptions when estimating redundant trunk muscle forces. An alternative powerful protocol that bypasses the calculation of muscle forces is to drive the detailed FE models by image-based in vivo displacements. Development of subject-specific models, however, both involves the risk of extensive radiation exposures while imaging in supine and upright postures and is time consuming in terms of the reconstruction of the vertebrae, discs, ligaments, and facets geometries. This study therefore aimed to introduce a...