Loading...
Search for:
recursive-least-square-algorithms
0.009 seconds
New method for assessing the utility harmonic impedance based on fuzzy logic
, Article IET Generation, Transmission and Distribution ; Volume 11, Issue 10 , 2017 , Pages 2448-2456 ; 17518687 (ISSN) ; Mokhtari, H ; Sharif University of Technology
Abstract
This study proposes a novel non-invasive method for estimating the utility harmonic impedance. Since the major concern about non-invasive methods is the dependency of the accuracy of the results on background harmonic fluctuations, proper measured samples are selected using a three-point data selection technique to increase the method accuracy. Then, a new non-invasive method for the evaluation of the utility harmonic impedance at a point of common coupling (PCC) based on fuzzy logic is presented. In the proposed method, fuzzy logic is applied to the constrained recursive least squares algorithm (CRLS) by designing a set of fuzzy if-then rules. Due to the changes in the quantities at a...
Adaptive handover algorithm in heterogeneous femtocellular networks based on received signal strength and signal-to-interference-plus-noise ratio prediction
, Article IET Communications ; Volume 8, Issue 17 , 27 November , 2014 , Pages 3061-3071 ; ISSN: 17518628 ; Yousefi, S ; Shayesteh, M. G ; Sharif University of Technology
Abstract
In this study, an efficient handover algorithm based on the received signal strength (RSS) prediction is presented for two-tier macro-femtocell networks in which, because of the fading effects of channel and short coverage range of femtocells, ping-pong handovers may take place. In the proposed approach, first each mobile station (MS) uses the recursive least square algorithm for predicting the RSS from the candidate base stations (BSs) including both femtocell and macrocell BSs. Then, according to the predicted RSS values, several future values of signal-to-interference plus noise ratio (SINR) are calculated. Afterwards, the candidate list of BSs is pruned according to the estimated future...
Introducing a distributed model of the heart
, Article Proceedings of the IEEE RAS and EMBS International Conference on Biomedical Robotics and Biomechatronics, 24 June 2012 through 27 June 2012 ; June , 2012 , Pages 419-424 ; 21551774 (ISSN) ; 9781457711992 (ISBN) ; Jahed, M ; Sharif University of Technology
2012
Abstract
Conventional models of cardiovascular system (CV) frequently lack required detail. Once utilized to study the heart function, these models focus primarily on the overall relationship between pressure, flow and volume. This study proposes a localized and regional model of the CV system. It utilizes non-invasive blood flow and pressure seed data and temporal cardiac muscle regional activation to predict the operation of the heart. Proposed localized analysis considers specific regions of the heart, namely base, mid and apex sections of the left ventricle. This modular system is based on a hydraulic electric analogy model, estimating desired parameters, namely resistance (R), compliance (C),...
Optimized decision feedback equalizer and comparison with MLSE algorithm for GSM channel
, Article Proceedings - 2011 UKSim 13th International Conference on Modelling and Simulation, UKSim 2011, 30 March 2011 through 1 April 2011, Cambridge ; 2011 , Pages 482-487 ; 9780769543765 (ISBN) ; Rahmati, A ; Hajisami, A ; Sharif University of Technology
2011
Abstract
In this paper, we present basic equation of efficient recursive least square algorithm based on GMSK modulation by linear superposition of amplitude modulated pulses for reduction complexity in equalizer. In this here, the DFE method be improved using of signal processing technique and soft decision which is called "generalized DFE or GDFEmethodquot;. We compare the performance and complexity GDFE with MLSE method for different channels used in GSM systems. The GDFE differs from the conventional DFE in its tap values and value of tap feedback filter related with channel length, which discussed in simulation result. Our simulation results, obtained for fading multi path channels, show that...
A novel distributed model of the heart under normal and congestive heart failure conditions
, Article Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine ; Volume 227, Issue 4 , 2013 , Pages 362-372 ; 09544119 (ISSN) ; Jahed, M ; Sharif University of Technology
2013
Abstract
Conventional models of cardiovascular system frequently lack required detail and focus primarily on the overall relationship between pressure, flow and volume. This study proposes a localized and regional model of the cardiovascular system. It utilizes noninvasive blood flow and pressure seed data and temporal cardiac muscle regional activity to predict the operation of the heart under normal and congestive heart failure conditions. The analysis considers specific regions of the heart, namely, base, mid and apex of left ventricle. The proposed method of parameter estimation for hydraulic electric analogy model is recursive least squares algorithm. Based on simulation results and comparison...