Loading...
Search for: roofs
0.012 seconds
Total 25 records

    Thermal performance evaluation of domed roofs

    , Article Energy and Buildings ; Volume 43, Issue 6 , June , 2011 , Pages 1254-1263 ; 03787788 (ISSN) Faghih, A. K ; Bahadori, M. N ; Sharif University of Technology
    2011
    Abstract
    Domed roofs have been used in Iran and many other countries to cover large buildings such as mosques, shrines, churches, schools. They have been also employed in other buildings like bazaars or market places in Iran due to their favorable thermal performance. The aim of this research is to study about domed roofs thermal performance in order to determine how they can be helpful in reducing the maximum air temperature of inside buildings during the warm seasons considering all parameters like air flow around them, solar radiation, radiation heat transfer with the sky and the ground as well as some openings on the building. The results of the study show that the thermal performance of the... 

    Solar radiation on domed roofs

    , Article Energy and Buildings ; Volume 41, Issue 11 , 2009 , Pages 1238-1245 ; 03787788 (ISSN) Faghih Khorasani, A. R ; Bahadori, M.N ; Sharif University of Technology
    2009
    Abstract
    Solar radiation received and absorbed by four domed roofs was estimated and compared with that of a flat roof. The domed roofs all had the same base areas, and equal to that of the flat roof. One of the roofs considered was the dome of the St. Peter's Church in Rome. Compared with the other roofs considered, this dome had a higher aspect ratio. It was found that all domed roofs received more solar radiation than the flat roof. Considering glazed tiles to cover a selected dome in Iran and the dome of the St. Peter's Church, it was found that the solar radiation absorbed by these roofs is reduced appreciably. In the case of the dome of St. Peter's Church, the amount of radiation absorbed was... 

    Three dimensional numerical simulation of air flow over domed roofs

    , Article NUMERICAL ANALYSIS AND APPLIED MATHEMATICS: International Conference on Numerical Analysis and Applied Mathematics, Corfu, 16 September 2007 through 20 September 2007 ; Volume 936 , 2007 , Pages 191-194 ; 0094243X (ISSN) ; 073540447X (ISBN); 9780735404472 (ISBN) Faghih Khorasani, A. R ; Bahadori, M. N ; Sharif University of Technology
    2007
    Abstract
    Using domed roofs to reduce building solar load in hot arid area is one of Iranian mechanical engineering masterworks. The first application of these roofs was to cover large buildings such as mosques, shrines, etc. However their thermal performance made them to be employed in other buildings like bazaars. The aim of this study was to determine the air pressure and velocity distribution over domed roofs, by employing numerical methods. The results of this study will be used as the first step for thermal performance evaluation of domed roofs. © 2007 American Institute of Physics  

    Effect of flexural and membrane stiffnesses on the analysis of floating roofs

    , Article International Journal of Engineering, Transactions A: Basics ; Volume 23, Issue 1 , 2010 , Pages 57-64 ; 17281431 (ISSN) Tariverdilo, S ; Shabani, R ; Salarieh, H ; Sharif University of Technology
    Materials and Energy Research Center 
    Abstract
    With the aim of extending the use of integrated variational principles on fluid and deck plate to the large deflection analysis of floating roofs, this paper investigates the significance of the flexural and membrane components in the formulations of the deck plate. Applying integrated variational principles on deck plate and fluid facilitate the treatment of the compatibility of deformation between floating roof and supporting liquid. Analysis results showed that different assumptions about deck plate formulation were commonly used in the literature which resulted in considerably different deflection and stress patterns on the floating roof. The results showed that modeling of the deck... 

    Shaking table tests on dome-roof adobe houses

    , Article Earthquake Engineering and Structural Dynamics ; Volume 46, Issue 3 , 2017 , Pages 467-490 ; 00988847 (ISSN) Bakhshi, A ; Ghannad, M ; Yekrangnia, M ; Masaeli, H ; Sharif University of Technology
    John Wiley and Sons Ltd  2017
    Abstract
    This paper presents the results of an experimental work in order to evaluate the performance of a novel proposed retrofitting technique on a typical dome-roof adobe building by shaking table tests. For this purpose, two specimens, scaled 2:3, were subjected to a total of nine shaking table tests. The unretrofitted specimen, constructed by common practice, is designed to evaluate seismic performance and vulnerability of dome-roof adobe houses. The retrofitted specimen, exactly duplicating the first specimen, is retrofitted based on the results obtained from unretrofitted specimen tests, and the improvement in seismic behavior of the structure is investigated. Zarand earthquake (2005) Chatrood... 

    Importance of the flexural and membrane stiffnesses in large deflection analysis of floating roofs

    , Article Applied Mathematical Modelling ; Volume 34, Issue 9 , 2010 , Pages 2426-2436 ; 0307904X (ISSN) Shabani, R ; Tariverdilo, S ; Salarieh, H ; Rezazadeh, G ; Sharif University of Technology
    2010
    Abstract
    Applying integrated variational principles on fluid and deck plate to the large deflection analysis of floating roofs, this paper investigates the significance of the flexural and membrane components in the formulations of the deck plate. Integrated variational principles facilitate the treatment of the compatibility of deformation between floating roof and supporting liquid. Analysis results show that different assumptions about deck plate formulation commonly used in the literature, results in considerably different deflection and stress patterns on the floating roof. The results show that modeling of the deck plate as a flexural element rather than the membrane, by eliminating the need... 

    Thermal Performance Evaluation of Domed Roofs

    , Ph.D. Dissertation Sharif University of Technology Faghih, Ahmad Reza (Author) ; Bahadori Nezhad, Mehdi (Supervisor)
    Abstract
    Domed roofs were commonly used in buildings with large areas. These roofs played an important role in the Iranian architecture and had a great effect on the buildings cooling loads. Solar energy absorption causes the roof temperature to increase in comparison with its ambient atmosphere. Wind flow removes some of the heat from the roof, and the rest goes thorough the roof and enters the building.The eometrical configuration of these domed roofs causes the wind velocity to increase over them, resulting in an increase in the convection heat transfer coefficient. Also, the heat transfer of the roof is accentuated by the fact that the area of a domed configuration is considerably greater than a... 

    Out-of-plane strength reduction of unreinforced masonry walls because of in-plane damages

    , Article Earthquake Engineering and Structural Dynamics ; Volume 44, Issue 13 , 2015 , Pages 2157-2176 ; 00988847 (ISSN) Dolatshahi, K. M ; Yekrangnia, M ; Sharif University of Technology
    John Wiley and Sons Ltd  2015
    Abstract
    There are numerous studies on the behavior of Unreinforced Masonry (URM) walls in both in-plane (IP) and out-of-plane (OP) directions; however, few aimed at understanding the simultaneous contribution of these intrinsic responses during earthquakes. Undoubtedly, even a strong URM wall shows weakened capacity in the OP direction because of minor cracks and other damages in the IP direction, and this capacity reduction has not yet been accounted for in seismic codes. In this study, performance of three URM walls is evaluated by several numerical analyses in terms of the OP capacity reduction because of IP displacements and failure modes. Several parameters influencing the OP capacity have been... 

    Evaluation of vierendeel peripheral frame as supporting structural element for prevention of progressive collapse

    , Article Steel and Composite Structures ; Volume 26, Issue 5 , March , 2018 , Pages 549-556 ; 12299367 (ISSN) Khaloo, A ; Omidi, H ; Sharif University of Technology
    Techno Press  2018
    Abstract
    Progressive building collapse occurs when failure of a structural component leads to the failure and collapse of surrounding members, possibly promoting additional failure. Global system collapse will occur if the damaged system is unable to reach a new static equilibrium configuration. The most common type of primary failure which led to the progressive collapse phenomenon, is the sudden removal of a column by various factors. In this study, a method is proposed to prevent progressive collapse phenomena in structures subjected to removal of a single column. A vierendeel peripheral frame at roof level is used to redistribute the removed column’s load on other columns of the structure. For... 

    Experimental investigation of air flow over domed roofs

    , Article Iranian Journal of Science and Technology, Transaction B: Engineering ; Volume 33, Issue 3 , 2009 , Pages 207-216 ; 10286284 (ISSN) Faghih Khorasani, A. R ; Bahador, M.N ; Sharif University of Technology
    2009
    Abstract
    Domed roofs have been used in Iran and many other countries to cover large buildings such as mosques, shrines, churches, schools, etc. However their favorable thermal performance has allowed them to be employed in other buildings like bazaars, or market places in Iran. In this investigation, wind pressure coefficients were determined experimentally for a domed roof model in a boundary layer wind tunnel. The model was a 1/10 scale model of the dome of an old school in the city of Yazd, in the central desert region of Iran. The model included a number of windows at the collar of the dome, and a hole on its apex. A total of 48 pressure tabs were employed to measure the air pressure at various... 

    Seismic Behavior Modeling of An Arched-Roof Adobe Building

    , M.Sc. Thesis Sharif University of Technology Hasani, Mojahed (Author) ; Bakhshi, Ali (Supervisor) ; Ghannad, Mohammad Ali (Supervisor)
    Abstract
    Statistical studies indicate the fact that in Iran, like many other developing countries, a considerable percentage of houses are in the form of traditional buildings, and major losses due to recent earthquakes are because of masonry building collapse. In the early twentieth century in Iran every ten years a destructive earthquake has been occurred which has resulted in huge human casualties and economic losses. After the Bam 2003 earthquake, a team project was defined to investigate the behavior of rural houses with the aim of providing solutions to lessen seismic hazards, and the current study is the fifth phase of the following line of investigations. Among the existing kinds of rural... 

    Numerical Analysis of Adobe Structure with Dome Roof under Earthquake Excitation

    , M.Sc. Thesis Sharif University of Technology Khajehpour, Mehdi (Author) ; Ghannad , Mohammad Ali (Supervisor) ; Bakhshi, Ali (Co-Advisor)
    Abstract
    After the heart-rending earthquake in Bam and its severe losses, the engineering community forced to pay special attention to the seismic vulnerability of traditional structures. Therefore, with the aim of reducing of such devastations to minimum, a multi-phase research project was defined at Sharif University of Technology to study the vulnerability and retrofitting of these structures which the current study is the eighth phase of that series research. In the third and fourth phases of this project, a typical adobe building with dome roof was chosen for study making use of shaking table facilities. The tests included both un-retrofitted and retrofitted states and considerable seismic... 

    Static and dynamic pushover analysis of steel moment resisting frames

    , Article 10th East Asia-Pacific Conference on Structural Engineering and Construction, EASEC 2010, Bangkok, 3 August 2006 through 5 August 2006 ; Volume 3 , 2006 , Pages 459-464 ; 9748257231 (ISBN); 9789748257235 (ISBN) Rasekh, A ; Rahimzadeh Rofooei, F ; Khajeh Ahmad Attari, N ; Shodja, A. H ; Sharif University of Technology
    2006
    Abstract
    Pushover analysis is a simplified nonlinear analysis technique that can be used to estimate the dynamic demands imposed on a structure under earthquake excitations. One of the first steps taken in this approximate solution is to assess the maximum roof displacement, known as target displacement, using the base shear versus roof displacement diagram. That could be done by the socalled dynamic pushover analysis, i.e. a dynamic time history analysis of an equivalent single degree of freedom model of the original system, as well as other available approximate static methods. In this paper, a number of load patterns, including a new approach, are considered to construct the related pushover... 

    Three dimensional numerical investigation of air flow over domed roofs

    , Article Journal of Wind Engineering and Industrial Aerodynamics ; Volume 98, Issue 3 , 2010 , Pages 161-168 ; 01676105 (ISSN) Faghih, A. K ; Bahadori, M. N ; Sharif University of Technology
    2010
    Abstract
    Domed roofs have been used in Iran and many other countries to cover large buildings such as mosques, shrines, churches, schools, etc. However their favorable thermal performance made them to be employed in other buildings such as bazaars, or market places, in Iran. The aim of this study was to determine the air pressure distribution over domed roofs, employing a numerical method. In this investigation, a three-dimensional model and a laminar inlet air flow were considered. The k-ε RNG method was employed for the turbulent flow simulation method. Simulation was run under three conditions of windows and a hole on top of the dome being open, or closed. The results were compared with the... 

    A numerical study of reactive pollutant dispersion in street canyons with green roofs

    , Article Building Simulation ; Volume 11, Issue 1 , February , 2018 , Pages 125-138 ; 19963599 (ISSN) Moradpour, M ; Afshin, H ; Farhanieh, B ; Sharif University of Technology
    Tsinghua University Press  2018
    Abstract
    Roof greening is a new technique for improvement of outdoor thermal environment which influences air quality through its impacts on thermal and flow field. In order to examine effects of green roofs on reactive pollutant dispersion within urban street canyons, a computational fluid dynamics (CFD) model was employed which contained NO-NO2-O3 photochemistry and energy balance models. Simulations were performed for street canyons with different aspect ratios (H/W) of 0.5, 1.0, and 2.0 such that leaf area density (LAD) of green roofs changed. It was found that roof greening led distribution of pollutants to alter for H/W = 0.5 and 1.0 cases in such a manner that their averaged concentrations had... 

    Evaluation of Seismic Performance of Adobe Dome-roof Structures Retrofitted by Steel Rods and Mesh Using Shaking Table Facility

    , M.Sc. Thesis Sharif University of Technology Yekrang, Mohammad (Author) ; Bakhshi, Ali (Supervisor) ; Ghannad, Mohammad Ali (Supervisor)
    Abstract
    Adobe buildings on one hand are very heavy and hence generate great amounts of inertia loads during earthquakes. Their response is also amplified in the high-frequency earthquake waves due to great stiffness. On the other hand, these structures proved vulnerable during past earthquakes because of low strength and ductility. Considering the fact that there are too many structures of this kind throughout the country and a majority of their residents are the poor, seismic retrofitting of these building should be taken as a priority rather than reconstruction. It is obvious that the proposed retrofitting technique should be simple, feasible and economical, as well. Among possible retrofitting... 

    The effect of geometry on structural behavior of buildings with steel plate shear wall system subjected to blast loading

    , Article International Journal of Steel Structures ; Volume 21, Issue 2 , 2021 , Pages 650-665 ; 15982351 (ISSN) Shabanlou, M ; Moghaddam, H ; Saedi Daryan, A ; Sharif University of Technology
    Korean Society of Steel Construction  2021
    Abstract
    Many important public buildings have suffered significant damages due to terrorist attacks in the last few decades. This paper investigates the behavior of structures with steel plate shear wall lateral load resisting system under various blast loadings. A number of twenty steel frames with different heights and widths subjected to four different blast scenarios are modeled and analyzed in opensees software. The results showed that structures with steel plate shear wall systems subjected to blast loading have better behavior in high-rise structures than in low-rise structures in terms of drift and ductility ratio. The steel plate shear wall system exhibited shear-dominated,... 

    Nonlinear vibrations and chaos in floating roofs

    , Article Journal of Computational and Nonlinear Dynamics ; Volume 7, Issue 2 , January , 2012 ; 15551415 (ISSN) Shabani, R ; Tariverdilo, S ; Salarieh, H ; Sharif University of Technology
    2012
    Abstract
    Variational principle is used to derive the nonlinear response of the floating roof of cylindrical liquid storage tanks due to harmonic base excitations. The formulation accounts for nonlinearity due to large deflections of the floating roof. The derived nonlinear governing equation for the sloshing response of the floating roof has a cubic nonlinear stiffness term similar to the well known Duffing equation. It is shown that accounting for large deflections could substantially reduce the wave elevation for near resonance harmonic excitations. Evaluating the response of the nonlinear model for increasing amplitudes of near resonance harmonic excitations gives rise to the appearance of sub and... 

    Surrogate SDOF models for probabilistic performance assessment of multistory buildings: Methodology and application for steel special moment frames

    , Article Engineering Structures ; Volume 212 , 2020 Vaseghiamiri, S ; Mahsuli, M ; Ghannad, M. A ; Zareian, F ; Sharif University of Technology
    Elsevier Ltd  2020
    Abstract
    This paper proposes a methodology for generating surrogate single-degree-of-freedom (SDOF) models that can be utilized to estimate the probability distribution of the roof drift ratio of multistory buildings at various ground motion intensity measures. The use of an SDOF model as a surrogate for multistory buildings can significantly alleviate the high computational cost for probabilistic seismic demand assessment considering both model uncertainty and record-to-record variability. The surrogate SDOF model generated herein explicitly accounts for model uncertainties and can be used as an alternative to the nonlinear dynamic analysis of detailed building structures. Applications for such... 

    Alternative solution for kinematic interaction problem of soil-structure systems with embedded foundation

    , Article Structural Design of Tall and Special Buildings ; Volume 22, Issue 3 , 2013 , Pages 251-266 ; 15417794 (ISSN) Jahankhah, H ; Ghannad, M. A ; Rahmani, M. T ; Sharif University of Technology
    2013
    Abstract
    An effective procedure to incorporate kinematic interaction (KI) aspects in seismic analysis of soil-structures systems was presented. In this regard, first, the effect of KI on the structural response was investigated with special focus on the role of rocking component of foundation input motion (FIM). This was performed parametrically for a wide range of selected nondimensional parameters, which well define the introduced simplified soil-structure model. It was observed that ignoring the effect of rocking input motion may introduce errors, which can be on the unsafe side especially for slender structures with large embedment ratios. On the other hand, it was known that introducing the...