Loading...
Search for: rotor-position
0.006 seconds

    Transient error compensation in sensorless control of PMSM

    , Article 2012 3rd Power Electronics and Drive Systems Technology, PEDSTC 2012, 15 February 2012 through 16 February 2012 ; February , 2012 , Pages 38-43 ; 9781467301114 (ISBN) Ghazimoghadam, M. A ; Tahami, F ; Sharif University of Technology
    2012
    Abstract
    Sensorless schemes based on HF carrier injection are capable of estimating rotor position in a wide speed range. In these schemes first an additional HF voltage is injected to stator windings. The corresponding HF current is decoupled from main stator currents and the position of the rotor saliency is estimated based on the decoupled HF current in a closed loop tracking observer. The tracking observer is capable of tracking rotor saliency with no steady state error. Transient error appears when the motor starts to move or whenever the rotor speed changes because of any disturbance or any change in the rotor speed command. In this paper a new solution is proposed in order to compensate for... 

    Sensorless control of PMSMs with tolerance for delays and stator resistance uncertainties

    , Article IEEE Transactions on Power Electronics ; Volume 28, Issue 3 , 2013 , Pages 1391-1399 ; 08858993 (ISSN) Moghadam, M. A. G ; Tahami, F ; Sharif University of Technology
    2013
    Abstract
    Position sensorless control of ac machines at zero and low speed is possible using high-frequency carrier injection methods. These methods utilize anisotropic properties of rotor. Therefore, they may lose their efficiency for nonsalient machines or machines with small rotor saliency. In these machines, measurement noise and offset, existing delays, as well as model uncertainties may lead to inaccurate estimation of rotor position. Stator resistance which is usually neglected in these methods may also lead to a considerable error especially in machines with small rotor saliency. In this paper, a new position estimation method is presented, and it is shown that in comparison to conventional... 

    Compensation of transient error in sensorless alternating carrier injection scheme

    , Article IECON Proceedings (Industrial Electronics Conference) ; 2012 , Pages 1702-1706 ; 9781467324212 (ISBN) Ghazimoghadam, M. A ; Tahami, F ; Sharif University of Technology
    2012
    Abstract
    High frequency (HF) carrier injection schemes can estimate rotor position in a wide speed range. In these methods, first a HF voltage is injected to stator windings and then the corresponding HF current is exploited to estimate the position of rotor using a closed loop tracking observer. The tracking observer is capable to track rotor saliency with no steady state error. However when the motor starts to move or whenever the rotor speed changes a transient error appears. In this paper a new solution is proposed to compensate the transient error in estimation of rotor position  

    A high-accuracy two-stage deep learning-based resolver to digital converter

    , Article 13th Power Electronics, Drive Systems, and Technologies Conference, PEDSTC 2022, 1 February 2022 through 3 February 2022 ; 2022 , Pages 71-75 ; 9781665420433 (ISBN) Khajueezadeh, M. S ; Emadaleslami, M ; Nasiri Gheidari, Z ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2022
    Abstract
    High-efficiency Permanent Magnet Synchronous Motors (PMSMs) are widely used in industrial applications. Subsequently, resolvers as position sensors experience increasing usage in the drive of PMSMs. Measuring the rotor's position using a resolver needs a costly Resolver to Digital Converter (RDC). Therefore, in this paper, a software-based, low-cost RDC is presented against the conventional Angle Tracking Observers (ATOs). The proposed RDC is a high-Accuracy two-stage Deep Neural Network (DNN)-based one. In this regard, an overview of the resolvers' function and the general methodology to DNN training is given. Then, the case study is done on the gathered data from the set of the resolver... 

    Sensorless control of non-salient PMSM using asymmetric alternating carrier injection

    , Article 2011 IEEE Symposium on Industrial Electronics and Applications, ISIEA 2011, 25 September 2011 through 28 September 2011 ; September , 2011 , Pages 7-12 ; 9781457714184 (ISBN) Ghazimoghadam, M. A ; Tahami, F ; Sharif University of Technology
    Abstract
    Sensorless control of permanent magnet synchronous motors allows reducing cost and complexity, and increasing mechanical robustness and noise immunity. Sensorless methods based on high frequency carrier injection have attracted considerable attention in recent years as they can estimate rotor position in a wide speed range. These methods employ anisotropic properties of rotor to estimate rotor position in ac machines. With internal permanent magnet motors, the high frequency signal injection method can deliver precise sensorless control, however in surface-mounted permanent magnet machines, where a small saliency arises from main flux saturation, the estimation of rotor magnet position is...