Loading...
Search for: sensitive-methods
0.012 seconds

    Defining interval for threshold in new thinning scheme

    , Article Proceedings - 2010 3rd IEEE International Conference on Computer Science and Information Technology, ICCSIT 2010, 9 July 2010 through 11 July 2010 ; Volume 6 , July , 2010 , Pages 108-112 ; 9781424455386 (ISBN) Firouzi, Z ; Mortazavi Far, L ; Sharif University of Technology
    2010
    Abstract
    Call admission control schemes are crucially Important concepts ID researches on cellular mobile networks. One of them is the new thinning scheme. In this study we define a confidence interval for threshold and the numerical results show the performance of the scheme in defined interval. Also we discuss the sensitivity of the scheme (in sample-based sensitivity method) at different thresholds. The results show the better performance in confidence thresholds and sensitivity of scheme into variations of thresholds  

    Differential pulse voltammetric determination of N-acetylcysteine by the electrocatalytic oxidation at the surface of carbon nanotube-paste electrode modified with cobalt salophen complexes

    , Article Sensors and Actuators, B: Chemical ; Volume 133, Issue 2 , 12 August , 2008 , Pages 599-606 ; 09254005 (ISSN) Shahrokhian, S ; Kamalzadeh, Z ; Bezaatpour, A ; Boghaei, D. M ; Sharif University of Technology
    2008
    Abstract
    The preparation and electrochemical performance of the carbon nanotube-paste electrode modified with salophen complexes of cobalt(III) perchlorate, with various substituents on the salophen ligand, as well as their electrocatalytic activity toward the oxidation of N-acetylcysteine (NAC) is investigated. Several Schiff base complexes containing various nucleophilic and electrophilic functional groups were prepared, and their electrochemical characteristics for the electro-oxidation of NAC were evaluated using cyclic and differential pulse voltammetry (CV and DPV). The results revealed, the modified electrodes show an efficient and selective electrocatalytic activity toward the anodic... 

    Liquid-liquid-liquid microextraction followed by HPLC with UV detection for quantitation of ephedrine in urine

    , Article Journal of Separation Science ; Volume 31, Issue 18 , 2008 , Pages 3212-3217 ; 16159306 (ISSN) Bagheri, H ; Khalilian, F ; Ahangar, L. E ; Sharif University of Technology
    2008
    Abstract
    Liquid-liquid-liquid microextraction (LLLME) in combination with HPLC and UV detection has been used as a sensitive method for the determination of ephedrine in urine samples. Extraction process was performed in a homemade total glass vial without using a Teflon ring, usually employed. Ephedrine was first extracted from 3.5 mL of urine sample (pH 12) into a microfilm of toluene/benzene (50:50). The analyte was subsequently back extracted into an acidic microdrop solution (pH 2) suspended in the organic phase. The extract was then injected into the HPLC system directly. An enrichment factor of 137 along with a good sample clean-up was obtained under the optimized conditions. The calibration...