    Optimization of HV generator insulation system based on electro-thermal analysis using FEM

    , Article Proceedings of the IASTED International Conference on Modelling and Simulation ; 2011 , Pages 288-293 ; 10218181 (ISSN) ; 9780889868878 (ISBN) Azizi, D ; Gholami, A ; Gholami, M. H ; Sharif University of Technology
    Abstract
    A large number of generators failed due to stator winding problems, mainly insulation deterioration. Insulation degradation assessment plays vital role in the asset life management. Electro thermal analysis is the main characteristic for simulation of generator behavior and to improve the design of stator slot's insulation. Dielectric parameters such as insulation thickness, spacing, material types, geometry of winding and slot are major design consideration. A very powerful method available to analyze electro thermal performance is Finite Element Method (FEM) which is used in this paper. The analysis of various stator coil and slot configurations are used to design the better dielectric...