Loading...
Search for: spine-fusion
0.003 seconds

    Biomechanical effects of lumbar fusion surgery on adjacent segments using musculoskeletal models of the intact, degenerated and fused spine

    , Article Scientific Reports ; Volume 11, Issue 1 , 2021 ; 20452322 (ISSN) Ebrahimkhani, M ; Arjmand, N ; Shirazi Adl, A ; Sharif University of Technology
    Nature Research  2021
    Abstract
    Adjacent segment disorders are prevalent in patients following a spinal fusion surgery. Postoperative alterations in the adjacent segment biomechanics play a role in the etiology of these conditions. While experimental approaches fail to directly quantify spinal loads, previous modeling studies have numerous shortcomings when simulating the complex structures of the spine and the pre/postoperative mechanobiology of the patient. The biomechanical effects of the L4–L5 fusion surgery on muscle forces and adjacent segment kinetics (compression, shear, and moment) were investigated using a validated musculoskeletal model. The model was driven by in vivo kinematics for both preoperative (intact or... 

    Optimization of cervical cage and analysis of its base material: A finite element study

    , Article Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine ; Volume 236, Issue 11 , 2022 , Pages 1613-1625 ; 09544119 (ISSN) Jalilvand, E ; Abollfathi, N ; Khajehzhadeh, M ; Hassani Gangaraj, M ; Sharif University of Technology
    SAGE Publications Ltd  2022
    Abstract
    Nowadays, cervical disorders are common due to human lifestyles. Accordingly, the cage design should be optimized as an essential issue. For an optimal design, an objective function is utilized to calculate the proper geometrical parameters. Additionally, the base material of the cage plays a key role in its functionality and final cost. Novel materials are currently introduced with more compatibility with the bone in terms of mechanical and chemical properties. In this study, a cervical cage was modeled based on PEEK material with three types of tooth designs on its surface. The cervical cage is assumed to be implanted between C6 and C7 vertebrae. The geometric parameters of the cage were... 

    Adjacent segments biomechanics following lumbar fusion surgery: a musculoskeletal finite element model study

    , Article European Spine Journal ; Volume 31, Issue 7 , 2022 , Pages 1630-1639 ; 09406719 (ISSN) Ebrahimkhani, M ; Arjmand, N ; Shirazi-Adl, A ; Sharif University of Technology
    Springer Science and Business Media Deutschland GmbH  2022
    Abstract
    Purpose: This study exploits a novel musculoskeletal finite element (MS-FE) spine model to evaluate the post-fusion (L4–L5) alterations in adjacent segment kinetics. Methods: Unlike the existing MS models with idealized representation of spinal joints, this model predicts stress/strain distributions in all passive tissues while organically coupled to a MS model. This generic (in terms of musculature and material properties) model uses population-based in vivo vertebral sagittal rotations, gravity loads, and an optimization algorithm to calculate muscle forces. Simulations represent individuals with an intact L4–L5, a preoperative severely degenerated L4–L5 (by reducing the disc height by ~... 

    Reliability and validity of the persian version of the scoliosis research society-22r questionnaire

    , Article Spine ; Volume 35, Issue 7 , 2010 , Pages 784-789 ; 03622436 (ISSN) Mousavi, S. J ; Mobini, B ; Mehdian, H ; Akbarnia, B ; Bouzari, B ; Askary Ashtiani, A ; Montazeri, A ; Parnianpour, M ; Sharif University of Technology
    2010
    Abstract
    STUDY DESIGN.: Cross-sectional validation study to investigate psychometric properties of adapted Persian version of the Scoliosis Research Society-22r (SRS-22r) questionnaire. OBJECTIVES.: To translate the SRS-22r into Persian and to evaluate the internal consistency, reliability, and validity of the Persian SRS-22r. SUMMARY OF BACKGROUND DATA.: The SRS-22r has not been translated and validated for Persian-speaking patients with idiopathic scoliosis. This was to provide a validated instrument to measure health-related quality of life in patients with idiopathic scoliosis in Iran. METHODS.: The translation and cultural adaptation of the original questionnaire were carried out in accordance... 

    A comprehensive approach for the validation of lumbar spine finite element models investigating post-fusion adjacent segment effects

    , Article Journal of Biomechanics ; Volume 121 , 2021 ; 00219290 (ISSN) Azadi, A ; Arjmand, N ; Sharif University of Technology
    Elsevier Ltd  2021
    Abstract
    Spinal fusion surgery is usually followed by accelerated degenerative changes in the unfused segments above and below the treated segment(s), i.e., adjacent segment disease (ASD). While a number of risk factors for ASD have been suggested, its exact pathogenesis remains to be identified. Finite element (FE) models are indispensable tools to investigate mechanical effects of fusion surgeries on post-fusion changes in the adjacent segment kinematics and kinetics. Existing modeling studies validate only their intact FE model against in vitro data and subsequently simulate post-fusion in vivo conditions. The present study provides a novel approach for the comprehensive validation of a lumbar...