Loading...
Search for: standard-errors
0.005 seconds

    Error resilient source coding for video communication

    , Article 2007 IEEE 15th Signal Processing and Communications Applications, SIU, Eskisehir, 11 June 2007 through 13 June 2007 ; 2007 ; 1424407192 (ISBN); 9781424407194 (ISBN) Ajorloo, H ; Lakdashti, A ; Manzuri Shalmani, M. T ; Sharif University of Technology
    2007
    Abstract
    A novel error resilient source coding method is proposed for video codecs such as H.264 standard. The main idea is to develop an error resilient part similar to the channel coders at the source coder. This enables the receiver to recover a damaged slice of a frame, inter or intra coded, up to a certain size determined by the encoder. In contrast to another previously approach presented in the literature, our algorithm has significantly less artifacts on the video frames with a considerable increase in speed  

    Useful multivariate kinetic analysis: Size determination based on cystein-induced aggregation of gold nanoparticles

    , Article Spectrochimica Acta - Part A: Molecular and Biomolecular Spectroscopy ; Volume 115 , 2013 , Pages 588-594 ; 13861425 (ISSN) Rabbani, F ; Nezhad, M. R. H ; Abdollahi, H ; Sharif University of Technology
    2013
    Abstract
    This study describes spectrometric monitored kinetic processes to determine the size of citrate-capped Au nanoparticles (Au NPs) based on aggregation induced by L-cysteine (L-Cys) as a molecular linker. The Au NPs association process is thoroughly dependent on pH, concentration and size of nanoparticles. Size dependency of aggregation inspirits to determine the average diameters of Au NPs. For this aim the procedure is achieved in aqueous medium at pH 7 (phosphate buffer), and multivariate data including kinetic spectra of Au NPs are collected during aggregation process. Subsequently partial least squares (PLS) modeling is carried out analyzing the obtained data. The model is built on the... 

    Test-retest reliability of postural stability measures during quiet standing in patients with a history of nonspecific low back pain

    , Article Biomedical Engineering - Applications, Basis and Communications ; Volume 22, Issue 3 , 2010 , Pages 255-262 ; 10162372 (ISSN) Mazaheri, M ; Salavati, M ; Negahban, H ; Parnianpour, M ; Sharif University of Technology
    2010
    Abstract
    As balance is the foundation for all voluntary motor skills, considerable research has been conducted to evaluate postural control in patients with low back pain (LBP). Although reliability is a population-specific property, to the authors' knowledge, there has been no study to determine the test-retest reliability of the center of pressure (COP) measures in the general population of LBP patients. As many as 11 patients with a history of nonspecific LBP randomly completed postural measurements with three levels of difficulty (rigid surface-eyes open, rigid surface-eyes closed, and foam surface-eyes closed) in two sessions. The COP data were used to calculate standard deviation of amplitude,...