Loading...
Search for: temperature-behaviors
0.005 seconds

    Analytical leakage-aware thermal modeling of a real-time system

    , Article IEEE Transactions on Computers ; Vol. 63, issue. 6 , 2014 , pp. 1377-1391 ; ISSN: 00189340 Mohaqeqi, M ; Kargahi, M ; Movaghar, A ; Sharif University of Technology
    Abstract
    We consider a firm real-time system with a single processor working in two power modes depending on whether it is idle or executing a job. The system is equipped with dynamic thermal management through a cooling subsystem which can switch between two cooling modes. Real-time jobs which arrive to the system have stochastic properties and are prone to soft errors. A successful job is one that enters the system and completes its execution with no timing or soft error. Appropriateness of the system is evaluated based on its performance, temperature behavior, reliability, and energy consumption. It is noteworthy that these criteria have mutual interactions to each other: the stochastic nature of... 

    Thermodynamic behavior of the XXZ Heisenberg s = 1/2 chain around the factorizing magnetic field

    , Article Journal of Physics Condensed Matter ; Volume 22, Issue 21 , May , 2010 ; 09538984 (ISSN) Abouie, J ; Langari, A ; Siahatgar, M ; Sharif University of Technology
    2010
    Abstract
    We have investigated the zero-and finite-temperature behaviors of the anisotropic antiferromagnetic Heisenberg XXZ spin-1/2 chain in the presence of a transverse magnetic field (h). The attention is concentrated on an interval of magnetic field between the factorizing field (hf) and the critical one (hc). The model presents a spin-flop phase for 0 < h < hf with an energy scale which is defined by the long range antiferromagnetic order while it undergoes an entanglement phase transition at h = hf. The entanglement estimators clearly show that the entanglement is lost exactly at h = hf, which justifies different quantum correlations on both sides of the factorizing field. As a consequence of... 

    Acrylamidevinyl acetate copolymer as a new UCST copolymer: Phase transition and aggregation behavior; an experimental and theoretical study

    , Article Reactive and Functional Polymers ; Volume 181 , 2022 ; 13815148 (ISSN) Karimi, A ; Kordzadeh, A ; Saadatabadi, A. R ; Sharif University of Technology
    Elsevier B.V  2022
    Abstract
    A high sensitive upper critical solution temperature (UCST) copolymer was synthesized through free radical copolymerization with acrylamide (AAm) and vinyl acetate (VA). The UCST behavior is due to a combination of hydrogen bonds and electrostatic potentials between copolymer chains. Turbidimetry, dynamic light scattering, and rheology studies were used to determine the phase transition and aggregation behavior. It is indicated that copolymer with 80% AAm has a phase transition temperature between 38 and 38.2 °C, which is suitable for releasing fever medicine. Also, the temperature gradient for the complete dissolution of the copolymer is 2 °C. The molecular dynamics simulations at a... 

    Analytical leakage/temperature-aware power modeling and optimization for a variable speed real-time system

    , Article ACM International Conference Proceeding Series ; 2012 , Pages 81-90 ; 9781450314091 (ISBN) Mohaqeqi, M ; Kargahi, M ; Movaghar, A ; Sharif University of Technology
    2012
    Abstract
    We consider a DVS-enabled single-processor firm real-time (FRT) system with Poisson arrival jobs having exponential execution times and generally distributed relative deadlines. The queue size of the system bounds the number of jobs which may be available therein. Further, the processor speed depends on the number of jobs in the system which varies because of the job arrivals, service completions, and dead-line misses. Thus, the processor power consumption, includling both the dynamic and leakage powers, depends on the stochastic nature of the system. More specifically, the instantaneous dynamic power consumption lonely depends on the number of jobs at that moment. However, the instantaneous... 

    Application of temperature transient analysis for welltest interpretation and well productivity evaluation

    , Article Society of Petroleum Engineers - SPE Asia Pacific Oil and Gas Conference and Exhibition, Jakarta, Indonesia,October 30–November 1, 2007 ; 2007 ; 9781613990407 (ISBN) Bahrami, N ; Siavoshi, J ; Sharif University of Technology
    2007
    Abstract
    During transient tests, both pressure and temperature are changed depending on downhole flow rate. In gas producing wells, Joule-Thomson cooling and frictional heating effects are the main dynamic factors causing flowing bottomhole temperature to differ from the static formation temperature at that depth. When a gas well is shut in, JT cooling effect is vanished and this causes a sharp increase in sandface temperature. As effect of wellbore storage ends, wellbore temperature gradually cools down due to heat conduction with near wellbore region. This paper demonstrates a new technique for using temperature transient data in gas wells in order to determine end of wellbore storage. Also, effect...