    Output voltage quality intensification of diode clamped multilevel inverters using FM PWM technique

    , Article 2012 3rd Power Electronics and Drive Systems Technology, PEDSTC 2012, 15 February 2012 through 16 February 2012 ; February , 2012 , Pages 98-102 ; 9781467301114 (ISBN) Najmi, V ; Ebrahimi, S ; Oraee, H ; Sharif University of Technology
    2012
    Abstract
    Improvement in switching techniques is one of the effective methods for increasing the voltage quality in Multilevel Inverters. In this paper, a novel switching technique using frequency modulation is proposed to achieve high quality output voltage of multilevel inverters. This method is employed to different configurations of multilevel inverters consist of Diode Clamped (or Neutral Point Clamped), Flying Capacitor and Cascaded H-bridge. Each multilevel inverter which utilizes this technique is modeled and simulated to investigate the performance of this method by the help of MATLAB/Simulink software. The Results show that this innovative method considerably reduces total harmonic... 

    A new definition for total harmonic distortion in inverter-fed induction motors including loss considerations

    , Article 42nd International Conference on Large High Voltage Electric Systems 2008, CIGRE 2008, Paris, 24 August 2008 through 29 August 2008 ; 2008 Fard, H. G ; Kaboli, S ; Oraee, H ; Sharif University of Technology
    2008
    Abstract
    Harmonic information is necessary tools in the estimation of motors life and performance. The conventional expression of harmonic amount is carried out by total Harmonic distortion. This distortion factor is only related to amplitude of harmonics while the motor loss is affected by frequency domain of them. In this paper a new definition of this factor has been presented. This definition includes the frequency of harmonics as well as their amplitudes. Experimental results verify the validity of this new definition  

    Optimization of THD and suppressing certain order harmonics in PWM inverters using genetic algorithms

    , Article Joint 2006 IEEE Conference on Control Applications (CCA), Computer-Aided Control Systems Design Symposium (CACSD) and International Symposium on Intelligent Control (ISIC), Munich, 4 October 2006 through 6 October 2006 ; 2006 , Pages 874-879 ; 0780397983 (ISBN); 9780780397989 (ISBN) Sayyah, A ; Aflaki, M ; Rezazade, A. R ; Sharif University of Technology
    2006
    Abstract
    In this paper the aim is to minimize the total harmonic distortion (THD) in PWM inverters while suppressing chosen harmonics concurrently and maintaining the fundamental component of the output voltage at a required level. This is reformed as an optimization task and the optimal pulse patterns are accomplished using genetic algorithm (GA) optimization technique to minimize a predefined fitness function. The complete solutions that suppress the 5 th and 7 th harmonics and optimize the THD are given. A practical limitation on the determination of sequential switching angles has been considered as a set of constraints in derivation of the results. © 2006 IEEE  

    Stable operation of grid connected Cascaded H-Bridge inverter under unbalanced insolation conditions

    , Article 2013 3rd International Conference on Electric Power and Energy Conversion Systems, EPECS 2013 2013 ; 2013 ; 9781479906888 (ISBN) Eskandari, A ; Javadian, V ; Iman Eini, H ; Yadollahi, M ; Sharif University of Technology
    2013
    Abstract
    This paper presents a single-phase Cascaded H-Bridge (CHB) inverter for photovoltaic applications. The proposed control strategy permits the optimum control of each string of PV panels in different insolation conditions. Based on the presented mathematical analysis, an analytic constraint is derived to check the stable operation of the inverter. A modified MPPT control strategy is also proposed based on this new condition. This strategy enhances the stability margins of the system by changing the operating point of some PV arrays. In this approach, the extracted power from high power cell is reduced to prevent instability issue and to avoid injection of highly distorted current into the... 

    A novel control strategy for power factor corrections based on predictive algorithm

    , Article PEDSTC 2010 - 1st Power Electronics and Drive Systems and Technologies Conference, 17 February 2010 through 18 February 2010, Tehran ; 2010 , Pages 117-121 ; 9781424459728 (ISBN) Yazdanian, M ; Farhangi, S ; Zolghadri, M. R ; Sharif University of Technology
    2010
    Abstract
    A novel control strategy based on predictive control is presented for continuous conduction mode boost converter which operates as a power factor correction. In the proposed algorithm two horizons for the behavior of the circuit are predicted which improves the total harmonic distortion, mainly the low frequency harmonics. The algorithm doesn't need elaborating calculations therefore, implementation of the controller using low price processor is feasible. Moreover, an extra horizon of the prediction leads to expansion of the calculation time. Reduction of the harmonic distortion of the input current and improvement of the power factor have been demonstrated on an isolated boost PFC converter... 

    Reducing output voltage THD of a three-phase inverter with non-linear load using disturbance observer

    , Article 8th Power Electronics, Drive Systems and Technologies Conference, PEDSTC 2017, 14 February 2017 through 16 February 2017 ; 2017 , Pages 431-436 ; 9781509057665 (ISBN) Valizade Alavi, S ; Tahami, F ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2017
    Abstract
    Non-linear loads such as rectifiers are growing in industry. Three phase inverter with non-linear load can lead to highly distorted output voltage. This paper proposes a method for reducing voltage THD in three phase inverters with non-linear load. The proposed method considers the load current as a disturbance and provide a control strategy to reject it using the disturbance observer method. This method doesn't need any additional sensors or hardware and is implemented digitally in controller. Simulation results show that the presented method will reduce the total harmonic distortion of the output voltage. © 2017 IEEE  

    Evaluating the capability of distribution networks to maintain power quality and voltage level, case study: alborz electric power distribution company

    , Article IET Generation, Transmission and Distribution ; Volume 12, Issue 16 , 2018 , Pages 3883-3891 ; 17518687 (ISSN) Jamshidieini, B ; Rezaie, K ; Fotuhi Firuzabad, M ; Sharif University of Technology
    Abstract
    Distribution system operators that seek operational excellence are supposed to design and implement capable processes throughout their value stream and assess how well their real services match the design specifications. Process capability analysis is a critical stage in systematic and sophisticated quality engineering approaches such as six sigma, which are based on quantitative studies. The capability of a distribution network to maintain the power quality and voltage level within an acceptable range is one of the most important aspects of design and utilisation of electricity distribution network. Capability analysis has been successfully used in the previous studies to assess the quality... 

    Comparison of common-mode voltage in three-phase quasi-Z-source inverters using different shoot-through implementation methods

    , Article Proceedings - 2018 IEEE 12th International Conference on Compatibility, Power Electronics and Power Engineering, CPE-POWERENG 2018 ; 4 June , 2018 , Pages 1-6 ; 9781538625088 (ISBN) Noroozi, N ; Zolghadri, M. R ; Yaghoubi, M ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2018
    Abstract
    In Z-source family inverters, shoot-through (ST) states are applied as a part of passive state in each switching cycle. The distribution of ST intervals along a switching period affects the system parameters as total harmonic distortion (THD), switching loss and common-mode voltage (CMV). In this paper, ST methods in a three-phase quasi-Z-source inverter (q-ZSI) are compared due to the CMV level. High-frequency harmonics of CMV cause leakage current flow in a transformerless grid-connected photovoltaic (PV) system. Through the comparison of the ST methods, the method with minimum CMV is identified. The experimental results are Prasented for a low voltage q-ZSI prototype. © 2018 IEEE  

    Simple voltage balancing approach for CHB multilevel inverter considering low harmonic content based on a hybrid optimal modulation strategy

    , Article IEEE Transactions on Power Delivery ; Volume 27, Issue 4 , July , 2012 , Pages 2150-2158 ; 08858977 (ISSN) Ghazanfari, A ; Mokhtari, H ; Firouzi, M ; Sharif University of Technology
    IEEE  2012
    Abstract
    This paper presents an effective hybrid optimal modulation technique for a cascaded H-bridge (CHB) multilevel inverter. The introduced method is generalized optimal pulsewidth modulation, which can be extended to any m-level CHB multilevel inverter operating at any switching frequency. The presented hybrid optimal modulation strategy includes the pattern exchange and optimal modulation techniques. In the optimal modulation technique, the hybrid interior-point algorithm, which is more flexible and efficient than conventional optimization techniques, is applied. The proposed hybrid optimal modulation strategy yields balanced units' output fundamental voltages, and low total harmonic distortion... 

    A novel modulation method for reducing common mode voltage in three-phase inverters

    , Article Conference Proceedings - 2017 17th IEEE International Conference on Environment and Electrical Engineering and 2017 1st IEEE Industrial and Commercial Power Systems Europe, EEEIC / I and CPS Europe 2017, 6 June 2017 through 9 June 2017 ; 2017 ; 9781538639160 (ISBN) Noroozi, N ; Zolghadri, M. R ; Yaghoubi, M ; Sharif University of Technology
    Abstract
    Leakage current is originated from common-mode voltage (CMV) time variations in a grid-connected photovoltaic (PV) system and results in several deficiencies. In this paper, a new method is proposed for CMV reduction in a three-phase voltage source inverter (VSI) system. The proposed method is based on space vector modulation and it utilizes only odd and zero vectors. By using the proposed method, the number of fluctuations of the CMV waveform per switching cycle is reduced; therefore, the amount of high-frequency harmonics of CMV is decreased. In addition, because of applying both active and zero vectors by the proposed method, the total harmonic distortion becomes less than most of other... 

    A fast and cost-effective control of a three-phase stand-alone inverter

    , Article 8th Power Electronics, Drive Systems and Technologies Conference, PEDSTC 2017, 14 February 2017 through 16 February 2017 ; 2017 , Pages 67-72 ; 9781509057665 (ISBN) Mazloum, N ; Keikha, O ; Yaghoubi, M ; Tahami, F ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2017
    Abstract
    This paper proposes a straightforward control method for voltage control of a three-phase transformer-based inverter in uninterruptible power supplies or distributed generation systems. The approach offers a dual-loop design consisting inner current control loop and outer voltage loop. Sliding mode current controller provides desired bandwidth for voltage controller which consists of a state feedback term for stabilization and resonant term for harmonic damping. The proposed scheme provides fast dynamic response and low total harmonic distortion even for high power inverters with the limitations of switching frequency and LC filter components. Experimental studies for 2KVA linear and... 

    Challenges of finite element analysis of re-solvers

    , Article IEEE Transactions on Energy Conversion ; 2018 ; 08858969 (ISSN) Saneie, H ; Alipour Sarabi, R ; Nasiri Gheidari, Z ; Tootoonchian, F ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2018
    Abstract
    Nowadays position sensors are increasingly used in many applications. One of the most commonly used sensors are resolvers. There are different types of resolvers including Wound Rotor (WR) resolvers, Variable Air-gap Length Variable Reluctance (VAGL-VR) resolvers, and Sinusoidal Rotor Variable Reluctance (SR-VR) resolvers. Regardless of the resolvers’ configurations, including linear, cylindrical and disk type, finite element analysis (FEA) is inseparable part of design and performance evaluation of these magnetic sensors. The scope of this study is to discuss challenges in the FEA of resolvers. The influence of mesh quality, time steps, stop time, excitation methods including volt-age... 

    Optimal distribution network reconfiguration considering power quality issues

    , Article 2017 IEEE Smart Grid Conference, SGC 2017, 20 December 2017 through 21 December 2017 ; Volume 2018-January , March , 2018 , Pages 1-6 ; 9781538642795 (ISBN) Nazerian, E ; Gharebaghi, S ; Safdarian, A ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2018
    Abstract
    Distribution network reconfiguration as a technique for reducing network losses and enhancing voltage profile has attracted attention of many researchers. In spite of impacts network reconfiguration can have on power quality indices, the potentials have not been studied enough. To fill the gap, this paper presents a method to determine optimum network configuration considering voltage profile, network losses, and total harmonic distortion (THD). The proposed method also vouches for radial structure of the network, supplying all loads, and maintaining voltages and currents within allowable bounds. Since network reconfiguration problem is a combinatorial optimization problem, a meta-heuristic... 

    A configurable high frequency Gm-C filter using a novel linearized Gm

    , Article AEU - International Journal of Electronics and Communications ; Volume 109 , 2019 , Pages 55-66 ; 14348411 (ISSN) Karami, P ; Atarodi, S. M ; Sharif University of Technology
    Elsevier GmbH  2019
    Abstract
    A large-signal linearization method for operational transconductance amplifiers (OTA) using a combination of cross-coupled quadratic cell and a novel non-linear current injection technique is presented in this paper. Post-layout simulations show that for 180 nm CMOS process with a 1.8 V power supply, total harmonic distortion (THD) at 1.5 V peak-to-peak and 5 kHz input is less than −46 dB. Also, the dynamic range (DR) at given THD is 68 dB with power consumption of 0.64 mW. To verify the performance, the proposed OTA is used to design a new configurable filter in high-frequency range using N-path filter methodology. Universal Butterworth Gm-C active filters are embedded in the proposed... 

    Challenges of Finite Element Analysis of Resolvers

    , Article IEEE Transactions on Energy Conversion ; Volume 34, Issue 2 , 2019 , Pages 973-983 ; 08858969 (ISSN) Saneie, H ; Alipour Sarabi, R ; Nasiri Gheidari, Z ; Tootoonchian, F ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2019
    Abstract
    Nowadays, position sensors are increasingly used in many applications. One of the most commonly used sensors are resolvers. There are different types of resolvers including wound rotor resolvers, variable air-gap length variable reluctance resolvers, and sinusoidal rotor variable reluctance resolvers. Regardless of the resolvers' configurations, including linear, cylindrical and disk type, finite element analysis (FEA) is inseparable part of design and the performance evaluation of these magnetic sensors. The scope of this study is to discuss challenges in the FEA of resolvers. The influence of mesh quality, time steps, stop time, excitation methods including voltage source and current... 

    Design optimization of a double-stage resolver

    , Article IEEE Transactions on Vehicular Technology ; Volume 68, Issue 6 , 2019 , Pages 5407-5415 ; 00189545 (ISSN) Alemi-Rostami, M ; Alipour Sarabi, R ; Rezazadeh, G ; Nasiri Gheidari, Z ; Oraee, H ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2019
    Abstract
    Accurate position estimation is an integral part of any motion control system. Besides, instantaneous position of poles plays an important role in electronic drive system of modern PM machines. Resolvers, due to their structure, are the most reliable position sensors in harsh environments. However, resolvers are not as accurate as optical encoders in normal conditions. To increase the accuracy of these sensors, various solutions are used, such as optimization in winding arrangement, rotor and stator contour, slot-pole combinations, and improvements in resolver-to-digital converter. In this paper, fractional slot concentrated winding is used in an axial flux resolver. By the aid of winding... 

    Improved winding proposal for wound rotor resolver using genetic algorithm and winding function approach

    , Article IEEE Transactions on Industrial Electronics ; Volume 66, Issue 2 , 2019 , Pages 1325-1334 ; 02780046 (ISSN) Alipour Sarabi, R ; Nasiri Gheidari, Z ; Tootoonchian, F ; Oraee, H ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2019
    Abstract
    Among position sensors, resolvers are superior from reliability point of view. However, obtaining lower output voltage harmonics and simple manufacturing process is a challenge in the design and optimization of resolvers. In this paper, a metaheuristic optimization algorithm is used to minimize total harmonic distortion of the output signals, and consequently the estimated position error in concentrated coil wound field resolvers. Meanwhile, to minimize total coil numbers, manufacturing costs, and complexity of the winding process, modified objective function and constraints are proposed. In this way, a modified winding function method is employed for performance analysis of the axial flux... 

    Performance analysis of concentrated wound-rotor resolver for its applications in high pole number permanent magnet motors

    , Article IEEE Sensors Journal ; Volume 17, Issue 23 , 2017 , Pages 7877-7885 ; 1530437X (ISSN) Alipour Sarabi, R ; Nasiri Gheidari, Z ; Tootoonchian, F ; Oraee, H ; Sharif University of Technology
    Abstract
    High pole number permanent magnet (PM) motors, due to their high torque density, have been receiving considerable attentions in recent years. To achieve an accurate position control in PM machines, resolvers are suggested for industrial applications. Mechanical and electromagnetic considerations in the case of high pole number resolvers lead the machine designers to choose small cores with low slot numbers. This paper proposes two different on-tooth winding configurations to achieve high pole number without increasing the slot numbers, while the accuracy of the detected position is intended to be the maximum value. Variable turn on tooth winding (VTTW) is compared with fractional slot...