Loading...
Search for: uang-s-method
0.004 seconds

    Response Modification Factor of Steel Plate Shear Walls in Concrete Structures

    , M.Sc. Thesis Sharif University of Technology Hosseinkhani, Ali (Author) ; Mofid, Massoud (Supervisor)
    Abstract
    The Steel shear wall is one of resisting lateral load system which has been used since 1970.with respect to design we can apply this system with or without stiffeners .here our investigation is about steel shear wall without stiffeners. Also this system is called SSW. Since using this system is new fashion, there is no specific code for it in Iranian 2800 code .also there is no code for using this system in reinforced concrete frames in any code which makes this investigation much harder. Need to obtain R which is one of the most important seismic parameters, encouraged us to consider R for SSW in 3 to 7 storey structures .we obtained static pushover curves with nonlinear static analysis... 

    Method of Estimating the Response Modification Factor for Stiffened Steel Shear Wall Systems

    , M.Sc. Thesis Sharif University of Technology Aslani, Jalal (Author) ; Bakhshi, Ali (Supervisor)
    Abstract
    Steel shear wall systems have been introduced as a lateral load resisting system since 1970s. Based on the designer’s choice, this system can be used with or without stiffeners. Employing stiffeners prevents the elastic buckling of steel plates which can enhance the system to absorb more energy. The design code for using stiffners has not developed yet in Iran since this kind of systems is not common practice. In this study, the Response Modification Factor (R), as an important factor in the design procedures of structures, is investigated for 2 to 10-story building structures which have steel shear walls with 3 and 6 millimeters thickness with 3, 4 and 6 meters spans.To this end, the... 

    Response Modification Factor of Steel Plate Shear Wall in Steel Structures

    , M.Sc. Thesis Sharif University of Technology Merati, Saeed (Author) ; Mofid, Massoud (Supervisor)
    Abstract
    Steel shear wall systems have been introduced as a lateral load resisting system since 1970s. Based on the designer’s choice, this system can be used with or without stiffeners. Employing stiffeners prevents the elastic buckling of steel plates which can enhance the system to absorb more energy. The design code for using stiffeners has not developed yet in Iran since this kind of systems is not common practice. In this study, the Response Modification Factor (R), as an important factor in the design procedures of structures, is investigated for 1,3,5,7 and 10-story regular and irregular building structures which have un-stiffened steel shear walls with 3, 4.5 and 6 millimeters thickness with...