    Experimental study of the punching behavior of GFRP reinforced lightweight concrete footing

    , Article Materials and Structures/Materiaux et Constructions ; Volume 50, Issue 6 , 2017 ; 13595997 (ISSN) Vatani Oskouei, A ; Pirgholi Kivi, M ; Araghi, H ; Bazli, M ; Sharif University of Technology
    Abstract
    This paper presents the results of an experimental study of structural lightweight concrete with glass fiber reinforcement (GFRP) bar for prefabricated single footing. In this study, seven full scale concrete single footings specimens, which were reinforced by GFRP bar located on a bed of soil, were tested. One of the specimens was made of normal weight concrete and the others were made of structural lightweight concrete. Four of the lightweight footing specimens contained polymer fibers. Also, two of the lightweight footing specimens contained shear reinforcement. Results indicated that the maximum GFRP strain on normal weight and lightweight concrete footing with polypropylene fibers are... 

    On the effect of ductility of confining material on concrete ductility

    , Article Proceedings of the 2009 Structures Congress - Don't Mess with Structural Engineers: Expanding Our Role, 30 April 2009 through 2 May 2009, Austin, TX ; 2009 , Pages 259-269 ; 9780784410318 (ISBN) Moghaddam, H. A ; Samadi, M ; Sharif University of Technology
    2009
    Abstract
    This paper presents the results of an experimental and analytical study on the improvements gained in the axial compressive behavior of confined concrete. Among several parameters affecting compressive ductility of confined concrete, including confinement mechanical volumetric ratio, shape and size effect, number of confinement layers, strength of plain concrete and ductility of confining material, the latter was found to play the most important role in determining the ultimate strain and post peak behavior of concrete. Axial compressive tests were performed on small-scale circular or square section concrete columns, which were retrofitted either by CFRP jacket or by two types of... 

    Compressive behavior of concrete actively confined by metal strips, part B: Analysis

    , Article Materials and Structures/Materiaux et Constructions ; Volume 43, Issue 10 , 2010 , Pages 1383-1396 ; 13595997 (ISSN) Moghaddam, H ; Samadi, M ; Pilakoutas, K ; Sharif University of Technology
    2010
    Abstract
    This paper presents analytical part of an investigation on the application of prestressed strips for concrete confinement. In this paper, an analytical model is proposed to predict the compressive stress-strain curve of strapped concrete as a function of the confinement level. The model was calibrated based on the experimental data of compressive tests which were described in part A of this paper. Various parameters are considered in the proposed model including volumetric ratio, yield strength and ultimate strain of confining material, shape of cross section, strength of plain concrete. Three key points were defined on the stress-stress curve of strapped concrete columns and applied in...