    Design of a broadband high frequency ultrasound transducer for skin imaging

    , Article 6th RSI International Conference on Robotics and Mechatronics, IcRoM 2018, 23 October 2018 through 25 October 2018 ; 2019 , Pages 261-265 ; 9781728101279 (ISBN) Babazadeh Khameneh, A ; Chabok, H. R ; Nejat, H ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2019
    Abstract
    This paper discusses the design of a high frequency wide bandwidth ultrasound transducer with the center frequency of 50 MHz and an aperture diameter of 3 mm for medical ultrasonic imaging. The piezoelectric material used in this design is Lithium Niobate. The design is verified by both KLM equivalent circuit and spatial impulse response method as used in FIELD II software and the theoretical imaging resolution has been calculated as 50 um axially and 80 um laterally. The possible applications of this probe are skin layer imaging, tumor detection and superficial blood flow measurement  

    Ultrasound dosimetery using microbubbles

    , Article IFMBE Proceedings, 20 June 2011 through 23 June 2011 ; Volume 35 IFMBE , June , 2011 , Pages 359-362 ; 16800737 (ISSN) ; 9783642217289 (ISBN) Rezayat, E ; Zahedi, E ; Tavakkoli, J ; Sharif University of Technology
    2011
    Abstract
    In this paper, a new technique based on nonlinear resonance of microbubbles is investigated in order to estimate the amplitude of an ultrasound wave pressure field. First, the existing theoretical model is reviewed. Then, an experimental setup consisting of a bubble generator and transmitting/receiving ultrasound transducers operating in the 1 MHz frequency range is described. The effect of background noise is also taken into account. Results show that the second harmonic oscillations are detectable, paving the way to develop a quantitative method for in vivo calibration of ultrasound waves  

    Blind angle and angular range detection in planar and limited-view geometries for photoacoustic tomography

    , Article 29th Iranian Conference on Electrical Engineering, ICEE 2021, 18 May 2021 through 20 May 2021 ; 2021 , Pages 922-926 ; 9781665433655 (ISBN) Hakakzadeh, S ; Kavehvash, Z ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2021
    Abstract
    In this paper, the relationship between the position of ultrasound transducers from the photoacoustic source and the reconstructed image is investigated. Our studies have shown that the distance of the transducer and its location from the photoacoustic source specifically affects and is closely related to the quality of the reconstructed image of the source. Also, we introduce a concept called blind angle for photoacoustic computed tomography (PACT) that have planar or circular limited-view geometry. Complete and accurate equations of this relationship are presented in this paper for all different 2D photoacoustic geometries. The main source of these equations is the spherically of the...