    Load sharing by decentralized control in an islanded voltage source converter-based Microgrid considering fixed frequency

    , Article Indian Journal of Science and Technology ; Volume 9, Issue 6 , 2016 ; 09746846 (ISSN) Nabati Rad, M ; Tavakoli, R ; Hassani, R ; Sharif University of Technology
    Indian Society for Education and Environment 
    Abstract
    Background/Objectives: In this paper by utilizing frequency tracking electrical loads are shared on voltage source converters and then by applying a proposed-supplementary control system, frequency changes during changing electrical loads inside network is omitted. Methods/Statistical Analysis: Using decentralized control in Microgrids and sharing loads on power generation units respect to their nominal capacity are unavoidable approaches to have stable and operational network. Droop control in load sharing is known as practical and significant solution. In droop control, units output frequency, changes proportional to output active power that is not preferable. Simulation results in PSCAD... 

    Robust Control Scheme for a Grid Connected DG System under Weak Grid Conditions

    , M.Sc. Thesis Sharif University of Technology Mahdian Dehkordi, Nima (Author) ; Namvar, Mehrzad (Supervisor) ; Karimi, Hoshang (Supervisor)
    Abstract
    Three-phase voltage source converter (VSC) is vastly utilized in the renewable energy resource and distributed generation (DG) systems interface units due to its high controllability and flexibility. Because of the high nonlinear nature of the system, the gird-connected inverter shows poor performance if the conventional control scheme are used. In this thesis, a new control scheme based on backstepping strategy is presented for control of a grid connected DG systems. The proposed scheme is responsible for regulating the active and reactive power components of the VSC power of the DG system. The VSC of the DG system is connected to a stiff utility grid through an L-type filter. In the first... 

    Decentralized Control of a Multi-DG Microgrid in Islanded Mode of Operation

    , M.Sc. Thesis Sharif University of Technology Moradi Kali Kand, Ramin (Author) ; Karimi, Houshang (Supervisor) ; Karimi, Masoud (Supervisor)
    Abstract
    A control strategy for islanded (autonomous) operation of a microgrid consisting of two Distributed Generation (DG) units is proposed in this thesis. The DG units are connected together in a radial configuration. Each DG unit utilizes a voltage-sourced converter (VSC) to interface to its dedicated load. The DG units and the loads are to operate in the islanded mode of operation. To provide autonomous operation for the microgrid, voltage and frequency of the loads should be regulated. The proposed control strategy utilizes (i) an internal oscillator for frequency control in an open loop manner and (ii) a decentralized servomechanism controller to regulate the load voltage. The microgrid is... 

    Enhanced control of grid forming VSCs in a micro-grid system under unbalanced conditions

    , Article 9th Annual International Power Electronics, Drive Systems, and Technologies Conference, PEDSTC 2018, 13 February 2018 through 15 February 2018 ; Volume 2018-January , April , 2018 , Pages 380-385 ; 9781538646977 (ISBN) Zarei, S. F ; Mokhtari, H ; Ghasemi, M. A ; SHarif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2018
    Abstract
    Due to the technical advances in power electronic industry, employing inverter-based distributed energy resources (IBDERs) are increased in electric power systems. Distributed generators (DGs) with the rating capacity of few megawatts are commonly connected to the distribution level of power systems which are inherently unbalanced. A cluster of IBDERs and loads form a small-scale grid called microgrid (MG) which can operate independent of the main grid. In a MG, grid forming voltage source converters (VSCs) are used to control the voltages and frequency of the MG. However, grid forming VSCs with conventional control schemes cannot do this task properly when the MG is unbalanced. In this... 

    Composite system reliability assessment incorporating an interline power-flow controller

    , Article IEEE Transactions on Power Delivery ; Volume 23, Issue 2 , 2008 , Pages 1191-1199 ; 08858977 (ISSN) Moghadasi, S. M ; Kazemi, A ; Fotuhi Firuzabad, M ; Edris, A. A ; Sharif University of Technology
    2008
    Abstract
    The impact of an interline power-flow controller (IPFC) on composite system delivery point and overall system reliability indices is examined in this paper. In this application, the IPFC with dc transmission lines is employed in a system for coordinated control of line impedances of two, distance away, transmission lines with the objective of managing power flows on the two lines. It is also used to balance the real power being transferred between the compensated lines. For this purpose, the reliability model associated with a converter station has been developed and incorporated in an IPFC reliability model. A number of reliability indices are calculated at both the loadpoint and system... 

    Reliability evaluation of an HVDC transmission system tapped by a VSC station

    , Article IEEE Transactions on Power Delivery ; Vol. 25, issue. 3 , 2010 , p. 1962-1970 ; ISSN: 8858977 Zadkhast, S ; Fotuhi-Firuzabad, M ; Aminifar, F ; Billinton, R ; Faried, S. O ; Edris, A. -A ; Sharif University of Technology
    Abstract
    Reliability evaluation of multiterminal HVDC systems has received very little attention in the past. This paper presents reliability modeling and analysis of an HVDC transmission system incorporating a voltage-sourced converter (VSC) tapping station. The use of VSC tapping stations enables the supply of power along the route to areas with comparatively little consumption. In this paper, a comprehensive detailed reliability model is developed and then converted to a manageable and computationally efficient model. Using this equivalent reliability model, various reliability indices are calculated at the load point of the system and the impacts of the VSC tapping station on these indices are... 

    Multiconverter unified power-quality conditioning system: MC-UPQC

    , Article IEEE Transactions on Power Delivery ; Volume 24, Issue 3 , 2009 , Pages 1679-1686 ; 08858977 (ISSN) Mohammadi, H. R ; Yazdian Varjani, A ; Mokhtari, H ; Sharif University of Technology
    2009
    Abstract
    This paper presents a new unified power-quality conditioning system (MC-UPQC), capable of simultaneous compensation for voltage and current in multibus/multifeeder systems. In this configuration, one shunt voltage-source converter (shunt VSC) and two or more series VSCs exist. The system can be applied to adjacent feeders to compensate for supply-voltage and load current imperfections on the main feeder and full compensation of supply-voltage imperfections on the other feeders. In the proposed configuration, all converters are connected back to back on the dc side and share a common dc-link capacitor. Therefore, power can be transferred from one feeder to adjacent feeders to compensate for... 

    Study of HVDC Transmission for Offshore Wind Farms Based on Voltage Source Converters

    , M.Sc. Thesis Sharif University of Technology Safaeian, Reza (Author) ; Parniani, Mostafa (Supervisor)
    Abstract
    In this thesis, DC transmission of offshore wind farms is studied thoroughly. Various system configurations that are introduced in the literatures are discussed and their control scheme for normal conditions and grid faults are studied. Then, the HVDC transmission based on voltage source converter, located between a local offshore ac grid and the onshore ac system is investigated as the most practical choice. The HVDC linke circuit elements are calculated and the control strategies of the offshore and onshore converters are introduced. DFIGs are considered to be the best choice for the offshore wind turbine generators. Then, the system is simulated and the frequency of the offshore grid is... 

    Controller parameters optimization for multi-terminal DC power system using ant colony optimization

    , Article IEEE Access ; Volume 9 , 2021 , Pages 59910-59919 ; 21693536 (ISSN) Ahmad, A ; Kashif, S. A. R ; Nasir, A ; Rasool, A ; Liaquat, S ; Padmanaban, S ; Mihet Popa, L ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2021
    Abstract
    Voltage source converter based multi - terminal DC grids (VSC - MTDC) are widely used for integration of renewable resources. Control of these grids requires vector control method, which includes inner and outer current controllers, tuning of these controllers is very important. Conventionally used tuning methods consider approximated linear model to tune the proportional - integral (PI) parameters of voltage source converter (VSC) which fails to produce optimum disturbance rejection results. In this research an Ant Colony Optimization (ACO) technique is used to get the optimum parameters of inner and outer power control layers for multi - terminal DC system. ACO is applied simultaneously on... 

    Controller parameters optimization for Multi-Terminal Dc power system using ant colony optimization

    , Article IEEE Access ; Volume 9 , 2021 , Pages 59910-59919 ; 21693536 (ISSN) Ahmad, A ; Kashif, S. A. R ; Nasir, A ; Rasool, A ; Liaquat, S ; Padmanaban, S ; Mihet-Popa, L ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2021
    Abstract
    Voltage source converter based multi - terminal DC grids (VSC - MTDC) are widely used for integration of renewable resources. Control of these grids requires vector control method, which includes inner and outer current controllers, tuning of these controllers is very important. Conventionally used tuning methods consider approximated linear model to tune the proportional - integral (PI) parameters of voltage source converter (VSC) which fails to produce optimum disturbance rejection results. In this research an Ant Colony Optimization (ACO) technique is used to get the optimum parameters of inner and outer power control layers for multi - terminal DC system. ACO is applied simultaneously on... 

    Stability Improvement and Protection of Grid-following Bidirectional Three-phase Voltage-sourced Converters under Unbalanced Grid Conditions

    , M.Sc. Thesis Sharif University of Technology Bahmani, Mehran (Author) ; Mokhtari, Hossein (Supervisor) ; Karimi, Houshang (Co-Supervisor)
    Abstract
    With the increasing expansion of modern DC loads and utilizing energy storage systems along with distributed renewable energy resources, grid-following bidirectional voltage-sourced converters (GFBVSCs) with fast dynamic performance are required. Due to the presence of single-phase loads and asymmetrical short circuit faults, unbalanced grid voltage conditions are available in the distribution system. Under unbalanced conditions, an oscillating component with a frequency of twice the grid angular frequency appears on the DC side. Removing double-frequency ripple in the DC link voltage without third harmonic current injection and reactive power injection to the grid based on the grid codes to... 

    Performance improvement of steady-state and transient operation of offshore wind farm HVDC power transmission

    , Article 2015 IEEE 16th Workshop on Control and Modeling for Power Electronics, COMPEL 2015, 12 July 2015 through 15 July 2015 ; July , 2015 , Page(s): 1 - 7 ; 9781467368476 (ISBN) Safaeian, R ; Ebrahimi, S ; Parniani, M ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2015
    Abstract
    Wind power generation is increasing fast as a clean renewable energy resource. Offshore wind farms are popular due to advantages such as higher and smoother wind speeds, less farm site limitations, etc. High capacitive currents and need to expensive compensations, make use of high-voltage-direct-current (HVDC) power transmission indispensable for longdistance wind farm power generations. Steady-state and transient performance improvements of HVDC systems have always been an interesting industrial and academic research area. In this paper, a novel control method is proposed to improve the steady-state operation of HVDC system. Moreover, a new fault detection scheme is proposed to improve the... 

    Robust decentralized control for islanded operation of two radially connected DG systems

    , Article 2010 IEEE International Symposium on Industrial Electronics, ISIE 2010, Bari, 4 July 2010 through 7 July 2010 ; July , 2010 , Pages 2272-2277 ; 9781424463916 (ISBN) Moradi, R ; Karimi, H ; Karimi Ghartemani, M ; The Institute of Electrical and Electronics Engineers (IEEE); IEEE Industrial Electronics Society (IES); IEEE Control Systems Society (CSS); Society of Instrument and Control Engineers (SICE-Japan); Politecnico di Bari ; Sharif University of Technology
    2010
    Abstract
    A decentralized servomechanism controller for islanded (autonomous) operation of radial connection of two distributed generation (DG) units is proposed in this paper. Each DG unit utilizes a voltage-sourced converter (VSC) for interface to its dedicated load. The DG units and the loads are to operate in the islanded mode of operation. Each DG unit regulates the voltage of its dedicated load in a decentralized manner. In this paper, it is first shown that the radial connection of two DG units in the islanded mode constitutes an interconnected composite system consisting of two subsystems. Moreover, the paper shows that the overall islanded system can be controlled by the local controllers,... 

    Reliability evaluation of an HVDC transmission system tapped by a VSC station

    , Article IEEE Transactions on Power Delivery ; Volume 25, Issue 3 , April , 2010 , Pages 1962-1970 ; 08858977 (ISSN) Zadkhast, S ; Fotuhi Firuzabad, M ; Aminifar, F ; Billinton, R ; Faried, S. O ; Edris, A. A ; Sharif University of Technology
    2010
    Abstract
    Reliability evaluation of multiterminal HVDC systems has received very little attention in the past. This paper presents reliability modeling and analysis of an HVDC transmission system incorporating a voltage-sourced converter (VSC) tapping station. The use of VSC tapping stations enables the supply of power along the route to areas with comparatively little consumption. In this paper, a comprehensive detailed reliability model is developed and then converted to a manageable and computationally efficient model. Using this equivalent reliability model, various reliability indices are calculated at the load point of the system and the impacts of the VSC tapping station on these indices are... 

    Reinforcing fault ride through capability of grid forming voltage source converters using an enhanced voltage control scheme

    , Article IEEE Transactions on Power Delivery ; 2018 ; 08858977 (ISSN) Zarei, F ; Mokhtari, H ; Ghasemi, M. A ; Blaabjerg, F ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2018
    Abstract
    Medium power distributed energy resources (DERs) are commonly connected to medium voltage distribution systems via voltage source converters (VSCs). Several guidelines and standards have been developed to establish the needed criteria and requirements for DERs interconnections. In this respect, it is preferred to reinforce the VSC fault ride through (FRT) capability, which considerably minimizes the DG outage period and reconnection time and results in a resilient system against short circuits. Considering the significant number of asymmetrical faults in distribution systems, the VSC response in such conditions must be investigated, and consequently, its FRT capability must be reinforced. In... 

    Reinforcing fault ride through capability of grid forming voltage source converters using an enhanced voltage control scheme

    , Article IEEE Transactions on Power Delivery ; Volume 34, Issue 5 , 2019 , Pages 1827-1842 ; 08858977 (ISSN) Zarei, S. F ; Mokhtari, H ; Ghasemi, M. A ; Blaabjerg, F ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2019
    Abstract
    Medium power distributed energy resources (DERs) are commonly connected to medium voltage distribution systems via voltage source converters (VSCs). Several guidelines and standards have been developed to establish the needed criteria and requirements for DERs interconnections. In this respect, it is preferred to reinforce the VSC fault ride through (FRT) capability, which considerably minimizes the DG outage period and reconnection time and results in a resilient system against short circuits. Considering the significant number of asymmetrical faults in distribution systems, the VSC response in such conditions must be investigated, and consequently, its FRT capability must be reinforced. In... 

    Robust decomposition and structured control of an islanded multi-DG microgrid

    , Article IEEE Transactions on Smart Grid ; Volume 10, Issue 3 , 2019 , Pages 2463-2474 ; 19493053 (ISSN) Babazadeh, M ; Nobakhti, A ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2019
    Abstract
    This paper presents a new robust control strategy for islanded operation of a microgrid consisting of several distributed generation (DG) units with arbitrary topology. Each DG unit is connected to its local load through a voltage-source converter, a series RL filter and a step-up transformer. The multi-DG microgrid with arbitrary connectivity graph is modeled as a linear time-invariant system subject to a parametric, norm-bounded uncertain block. By utilizing the developed model for multi-DG microgrids, a systematic approach for the design of structured dynamic output feedback control is proposed. A convex optimization problem is developed which yields a low-order dynamic controller of... 

    Stand alone performance of permanent magnet synchronous wind power generator with current source matrix converter

    , Article Electric Power Components and Systems ; Volume 43, Issue 8-10 , 2015 , Pages 1018-1027 ; 15325008 (ISSN) Hojabri, H ; Mokhtari, H ; Chang, L ; Sharif University of Technology
    Taylor and Francis Inc  2015
    Abstract
    A matrix converter is a voltage/current source AC/AC frequency converter. In grid-connected operation of a variable-speed permanent magnet synchronous wind power generator, the matrix converter is normally controlled as a voltage source converter. In this control method, the generator-side voltage is synthesized from the grid-side voltage source. However, in the stand-alone mode of operation, the grid-side stiff voltage source is not available, and the input filter of the matrix converter is unstable. In this article, a new control method is presented that controls a permanent magnet synchronous wind generator in a stand-alone mode with a matrix converter as a current source converter. The... 

    Decentralized control of parallel connection of two distributed generation units

    , Article 35th Annual Conference of the IEEE Industrial Electronics Society, IECON 2009, Porto, 3 November 2009 through 5 November 2009 ; 2009 , Pages 358-362 Bahrani, B ; Karimi, H ; Iravani, R ; Sharif University of Technology
    Abstract
    This paper presents a decentralized control strategy for the autonomous (islanded) operation of parallel connection of two distributed generation (DG) units. The DG units are electronically interfaced to the host grid at the same point of common coupling (PCC), where the local load is also supplied. In the grid-connected mode, the voltage-sourced converter (VSC) of each DG unit controls the exchange of real and reactive power components with the host grid, based on the conventional dq-current control strategy. In the islanded mode, one of the DG units provides voltage and frequency control for the island, and the other DG unit continues to operate with the pre-islanding dq-current control...