Gas Condensate Separation by Using Vortex Tube, Ph.D. Dissertation Sharif University of Technology ; Farhadi, Fatolah (Supervisor)
Abstract
A brass vortex tube (VT) with changeable parts is used to investigate the effect of nozzle intakes number and diameter, distance between cold end orifice and nozzle intakes, cold end orifice diameter, main tube length and diameter on inlet, cold and hot exit temperature difference, isentropic efficiency and Coefficient of Performance. A series of experiments conducted to investigate the inlet pressure and cold fraction effect on VT performance and an optimum amount for this parameter is found. The separation performances of a VT for a hydrocarbon mixture is also investigated. Effects of nozzle intakes number and cold fraction on the gas species separation at specific inlet pressure in a VT...
Cataloging briefGas Condensate Separation by Using Vortex Tube, Ph.D. Dissertation Sharif University of Technology ; Farhadi, Fatolah (Supervisor)
Abstract
A brass vortex tube (VT) with changeable parts is used to investigate the effect of nozzle intakes number and diameter, distance between cold end orifice and nozzle intakes, cold end orifice diameter, main tube length and diameter on inlet, cold and hot exit temperature difference, isentropic efficiency and Coefficient of Performance. A series of experiments conducted to investigate the inlet pressure and cold fraction effect on VT performance and an optimum amount for this parameter is found. The separation performances of a VT for a hydrocarbon mixture is also investigated. Effects of nozzle intakes number and cold fraction on the gas species separation at specific inlet pressure in a VT...