Loading...
Leakage diagnosis using closed-form solution and linear observer
Derakhshan, M ; Sharif University of Technology | 2018
443
Viewed
- Type of Document: Article
- DOI: 10.1109/ICCIAutom.2017.8258688
- Publisher: Institute of Electrical and Electronics Engineers Inc , 2018
- Abstract:
- In this paper, an approach is proposed to estimate the location of leakages in liquid transmission lines with a high accuracy. First, the mathematical model is analyzed and a closedform solution is provided for the partial differential equations of the pipeline. Next, the leakage location is calculated using the closed-form solution. The calculations are applied to various leakages and are extended to a case in which the pressure and flowrate do not converge to constant values. Considering a singleleakage pipeline system, a linear observer is utilized to estimate the leakage location with reduced errors. The simulation results are presented and the proposed method is verified by changing the location of the leak. © 2017 IEEE
- Keywords:
- Estimation ; Partial differential equations ; Pipelines ; Closed form solutions ; Constant values ; High-accuracy ; Leakage diagnosis ; Leakage locations ; Linear observer ; Pipe-line systems ; Location
- Source: 5th International Conference on Control, Instrumentation, and Automation, ICCIA 2017, 21 November 2017 through 23 November 2017 ; Volume 2018-January , 2018 , Pages 255-258 ; 9781538621349 (ISBN)
- URL: https://ieeexplore.ieee.org/document/8258688