Application of advanced SVC incase of reactive power and unbalancy compensation of a locomotive
Saghaleini, M ; Sharif University of Technology | 2006
234
Viewed
- Type of Document: Article
- DOI: 10.1109/ICIT.2006.372452
- Publisher: 2006
- Abstract:
- This paper introduces advanced SVC. Advanced SVC has been simulated with regard to reactive power and unbalancy compensation. Then, a new space has been chosen for state equation based on combination of d-q and real space to positive - negative. By decoupling of active, reactive powers and positive, negative sequences and using decoupling circuit, the facility of each sequence control, by control circuit will be provided independently. After advanced SVC modeling, the load - which is electrification railway system - will be simulated. So a sample of electric locomotive in Iran has been investigated and simulated. By using the load model, the advanced SVC has been used for compensation of reactive power, and unbalancy. For more accurate results, the advanced SVC has been investigated during unbalancy and reactive power compensation of the electric locomotive. The results reveal the ability of advanced SVC for simultaneous compensation of reactive power and unbalancy
- Keywords:
- Industrial technologies ; International conferences ; Railway systems ; Computer networks ; Electric locomotives ; Electric power factor ; Electric railroads ; Electric utilities ; Locomotives ; Turbulent flow ; Reactive power
- Source: 2006 IEEE International Conference on Industrial Technology, ICIT, Mumbai, 15 December 2006 through 17 December 2006 ; 2006 , Pages 1897-1902 ; 1424407265 (ISBN); 9781424407262 (ISBN)