Loading...

Modelling of the effect of operational parameters and concentration of some corrosion inhibitors on the corrosion of carbon steel

Mosayebi, B ; Sharif University of Technology | 2002

103 Viewed
  1. Type of Document: Article
  2. DOI: 10.1108/00035590210452770
  3. Publisher: 2002
  4. Abstract:
  5. Several corrosion inhibitors, such as, HEDP, sodium molybdate and zinc ions, were added to an aqueous corrosive media containing different concentrations chloride ions, and the corrosion rates (CRs) of carbon steel were measured at various temperatures. It was shown that, in the presence of more than 1,200 ppm of chloride ions, and temperatures greater than or equal to 42.5°C, the combination of HEDP, molybdate and zinc could not control the corrosion in a cooling water system. Then four different models were designed to represent the CR of carbon steel in presence of various corrosive parameters
  6. Keywords:
  7. Corrosion inhibitors ; Modelling ; Steel ; Zinc
  8. Source: Anti-Corrosion Methods and Materials ; Volume 49, Issue 6 , 2002 , Pages 426-432 ; 00035599 (ISSN)
  9. URL: https://www.emerald.com/insight/content/doi/10.1108/00035590210452770/full/html