Direct Torque Control of Doubly-Fed Induction Motor, M.Sc. Thesis Sharif University of Technology ; Kaboli, Shahriyar (Supervisor)
Abstract
Conventional induction motors are controlled by stator voltage, so the inverter should pass the full power of the motor. In the doubly-fed rotor wound induction motors, the nominal power of inverter can be reduced. Therefore, these types of machines have been concerned in recent decades and they are able to use as alternative for high power conventional induction machines in the future. Direct torque control is one of the well known methods for controlling the induction motors. Fast torque response and independence of machine parameters (except winding resistance). In this thesis, different sterategies of direct torque control of doubly fed induction motors are presented. In the first...
Cataloging briefDirect Torque Control of Doubly-Fed Induction Motor, M.Sc. Thesis Sharif University of Technology ; Kaboli, Shahriyar (Supervisor)
Abstract
Conventional induction motors are controlled by stator voltage, so the inverter should pass the full power of the motor. In the doubly-fed rotor wound induction motors, the nominal power of inverter can be reduced. Therefore, these types of machines have been concerned in recent decades and they are able to use as alternative for high power conventional induction machines in the future. Direct torque control is one of the well known methods for controlling the induction motors. Fast torque response and independence of machine parameters (except winding resistance). In this thesis, different sterategies of direct torque control of doubly fed induction motors are presented. In the first...
Find in contentBookmark |
![]() |
|