Loading...

Application of pyrolytic graphite modified with nano-diamond/graphite film for simultaneous voltammetric determination of epinephrine and uric acid in the presence of ascorbic acid

Shahrokhian, S ; Sharif University of Technology | 2010

1614 Viewed
  1. Type of Document: Article
  2. DOI: 10.1016/j.electacta.2010.08.043
  3. Publisher: 2010
  4. Abstract:
  5. A novel modified pyrolytic graphite electrode with nano-diamond/graphite was fabricated. The electrochemical response characteristics of the modified electrode toward the epinephrine (EN) and uric acid (UA) were studied by means of cyclic and linear sweep voltammetry. The structural morphology and thickness of the film was characterized by SEM technique. The prepared electrode showed an excellent catalytic activity in the electrochemical oxidation of EN and UA, leading to remarkable enhancements in the corresponding peak currents and lowering the peak potentials. The prepared modified electrode acts as a highly sensitive sensor for simultaneous determination of EN and UA in the presence of ascorbic acid (AA). The electrode showed an excellent activity to resolving EN and UA peaks and completely eliminates the interfering effect of AA. The current response of the electrode showed a linear relationship with the concentrations of EN and UA in the range of 0.01-10 μM and 0.01-60 μM, respectively. In these measurements a detection limit of 3 nM is resulted for both compounds. This sensor exhibited very good reproducibility, repeatability and sensitivity for the determination of EN in the human blood serum, urine and the corresponding injecting samples. Moreover, the linear range and the detection limit of the determinations in the real samples remained constant in comparison with the measurements in the pure buffer solution
  6. Keywords:
  7. Modified electrode ; Uric acid ; Ascorbic acids ; Buffer solutions ; Catalytic activity ; Current response ; Detection limits ; Electrochemical response ; Epinephrine ; Highly sensitive ; Human bloods ; Interfering effect ; Linear range ; Linear relationships ; Linear sweep voltammetry ; Modified electrodes ; Nanodiamond/graphite ; Peak currents ; Peak potentials ; Pyrolytic graphite ; Pyrolytic graphite electrodes ; Real samples ; Reproducibilities ; SEM ; Simultaneous determinations ; Structural morphology ; Thickness of the film ; Uric acids ; Voltammetric determination ; Body fluids ; Catalyst activity ; Catalytic oxidation ; Electrochemical oxidation ; Film preparation ; Graphite ; Graphite electrodes ; Ketones ; Nanosensors ; Organic acids ; Voltammetry ; Electrochemical electrodes
  8. Source: Electrochimica Acta ; Volume 55, Issue 28 , 2010 , Pages 9090-9096 ; 00134686 (ISSN)
  9. URL: http://www.sciencedirect.com/science/article/pii/S0013468610011163