Loading...
Search for: amputation
0.01 seconds

    Effects of prosthetic mass distribution on the spatiotemporal characteristics and knee kinematics of transfemoral amputee locomotion

    , Article Gait and Posture ; Volume 37, Issue 1 , 2013 , Pages 78-81 ; 09666362 (ISSN) Hekmatfard, M ; Farahmand, F ; Ebrahimi, I ; Sharif University of Technology
    2013
    Abstract
    This study was designed to investigate the effect of changing the location of the center of mass (COM) of transfemoral prostheses on the spatiotemporal and kinematical characteristics of the amputee gait, while maintaining the prosthetic mass fixed. Ten men with unilateral traumatic transfemoral amputation participated in gait analysis, 2-min walk and subject preference tests. Weights were added to the original prosthetic legs in three conditions: 600. g added to the ankle, 600. g added at 10. cm distal to the prosthetic knee, and 300. g added to the ankle, and 300. g at 10. cm distal to the knee. For each prosthetic mass condition, the stride and step lengths, stepping speed, stance, swing... 

    Design and Fabrication of a Robotic Prosthetic Finger

    , M.Sc. Thesis Sharif University of Technology Maskoot, Keyan (Author) ; Bagheri Shouraki, Saeed (Supervisor)
    Abstract
    Due to diversity in amputation possibilities, this thesis focuses on the specific case of ring finger amputation with some amount of stomp remaining. The goal is to design a robotic finger as a prosthetic, which its flexion and extension (position control) are instructed from an armband. The armband is equipped with 8 force sensors to detect volume variations in patient’s forearm. Its embedded microcontroller processes signals taken from these sensors, and using machine learning techniques (K-Nearest Regressor), decides on a specific angle for the finger. This angle value updates constantly, and using a flex sensor and a DC motor in finger, the desired flexion/extension is performed.... 

    Differences in muscle synergies between healthy subjects and transfemoral amputees during normal transient-state walking speed

    , Article Gait and Posture ; Volume 76 , February , 2020 , Pages 98-103 Mehryar, P ; Shourijeh, M. S ; Rezaeian, T ; Khandan, A. R ; Messenger, N ; O'Connor, R ; Farahmand, F ; Dehghani Sanij, A ; Sharif University of Technology
    Elsevier B. V  2020
    Abstract
    Background: Lower limb amputation is a major public health issue globally, and its prevalence is increasing significantly around the world. Previous studies on lower limb amputees showed analogous complexity implemented by the neurological system which does not depend on the level of amputation. Research question: What are the differences in muscle synergies between healthy subjects (HS) and transfemoral amputees (TFA) during self-selected normal transient-state walking speed? Methods: thirteen male HS and eleven male TFA participated in this study. Surface electromyography (sEMG) data were collected from HS dominant leg and TFA intact limb. Concatenated non-negative matrix factorization... 

    Design and fabrication of a new expandable transtibial liner with manual volume control: A prototype

    , Article Journal of Biomedical Physics and Engineering ; Volume 10, Issue 4 , 2020 , Pages 543-548 Nouri, M. J ; Aminian, G ; Farahmand, F ; Rahgozar, M ; Sharif University of Technology
    Shiraz University of Medical Sciences  2020
    Abstract
    Diurnal volume changes is one of the main factors influencing socket fit in trans-tibial prosthesis and causing pressure problem issues. Embedded bladder liners have been recently a potential approach to deal with this problem. The aim of this technical note was to introduce a new transtibial silicone liner designed based on hybrid socket theory. To make expandability in the liner, an integrated wax structure was constructed over the selected areas of the positive model and then removed after lamination process. In addition, a mechanical system with manual control was designed to fit the liner with the residual limb volume by pumping the water in or out of the liner through connec-tive... 

    Design optimization of an above-knee prosthesis based on the kinematics of gait

    , Article 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS'08, Vancouver, BC, 20 August 2008 through 25 August 2008 ; 2008 , Pages 4274-4277 ; 9781424418152 (ISBN) Pejhan, S ; Farahmand, F ; Parnianpour, M ; Sharif University of Technology
    2008
    Abstract
    A dynamic model of an above-knee prosthesis during the complete gait cycle was developed. The model was based on a two-dimensional multi-body mechanical system and included a hydraulic and an elastic controller for the knee and a kinematical driver controller for the prosthetic ankle. The equations of motion were driven using Lagrange method. Simulation of the foot contact was conducted using a two-point penetration contact model. The knee elastic and hydraulic controller units, the knee extension stop, and the kinematical driver controller of the ankle were represented by a spring and a dashpot, a nonlinear spring, and a torsional spring-damper within a standard prosthetic configuration.... 

    Kinematic and dynamic analysis of the gait cycle of above-knee amputees

    , Article Scientia Iranica ; Volume 13, Issue 3 , 2006 , Pages 261-271 ; 10263098 (ISSN) Farahmand, F ; Rezaeian, T ; Narimani, R ; Hejazi Dinan, P ; Sharif University of Technology
    Sharif University of Technology  2006
    Abstract
    The change of gait pattern and muscular activity following amputation is thought to be responsible for the higher incidence of joint degenerative disorders observed in amputees. Considering the lack of consistent data in the literature, the purpose of the present study was to measure and analyze the spatio-temporal variables, the kinematics and, particularly, the net joint moments of the intact and prosthetic limbs of above knee amputee subjects during walking and to compare the results with those of normals. The gait characteristics of five transfemoral amputees and five normal subjects were measured using videography and a force platform. The human body was modeled as a 2-D sagittal plane...